City Of Hurst

PFAS monitoring results for a public water system in Texas

TX2200054UCMR 5EPA monitoring data
<MRLHighest PFOA result, ppt
<MRLHighest PFOS result, ppt
0Highest Hazard Index
300Results
PWSID
TX2200054
State
Texas
System type
community water system (CWS)
Population served
40,454
City
Hurst
Counties
Tarrant County
Primary source water
surface water (purchased)
UCMR 5 sampling
2023-05-09 to 2024-07-29 · 4 entry point(s) · water types: GW;SW
Service-area boundary
authoritative

Other PFAS detected highest single result
Other PFAS detected worst entry-point average

These are monitoring results collected under EPA's Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) at entry points, where treated water enters the distribution system; they are not tap-water samples. They are not compliance determinations: compliance with EPA's 2024 PFAS limits is judged on running annual averages of compliance monitoring, required from 2029, so a single UCMR 5 result at or above a limit is not a violation. “< MRL” means the compound was not quantified at EPA's minimum reporting level; it does not mean zero.

Water purchased from

  • Tra Tarrant County Water Project (TX2200199)
    Seller not monitored under UCMR 5.
  • City Of Colleyville (TX2200043)
    Seller's highest results: PFOA <MRL · PFOS 5.4 ppt · HI 0.322 · detected: PFBA;PFBS;PFHxA;PFHxS;PFOS;PFPeA
  • City Of Fort Worth (TX2200012)
    Seller's highest results: PFOA 8.3 ppt · PFOS 7.3 ppt · HI 2.583 · detected: PFBA;PFBS;PFHxA;PFHxS;PFOA;PFOS;PFPeA

Seller results are the seller's own entry-point samples, not measurements of this system's water. This system's own samples (below) may reflect purchased water, its own sources, or both.

Compared with EPA's 2024 values

Highest single resultWorst entry-point average*Limit
PFOA (ppt)<MRL04
PFOS (ppt)<MRL04
Hazard Index001.0†

“<MRL” = every result for the compound was below its reporting limit. * Mean of all samples at each entry point with non-detects = 0 (EPA compliance convention; the Hazard Index also uses non-detects = 0); a screening comparison, not a formal running annual average. † Rescission proposed May 2026. PFOA/PFOS MCL 4 ppt (2024 NPDWR, in effect). PFHxS, PFNA, HFPO-DA (10 ppt each) and the Hazard Index (1.0) are 2024 NPDWR values; EPA proposed rescinding them on 18 May 2026 (comment period closed 20 Jul 2026).

No Texas PFAS drinking-water standard in effect or proposed as of 2026-10-17: No state PFAS drinking-water standard; TCEQ implementing federal NPDWR (BCLP state survey, Jan 2026).

Sampling history

Sampled 2023-05-09 to 2024-07-29 · 4 entry point(s) · water types: GW;SW · 11 sampling visits. PFAS in ppt (ng/L).

DateEntry pointEventPFOAPFOSHIOther detections
2023-05-09Master Meter (SW)SE1<4<40PFBA 5.5, PFPeA 3.1
2023-05-09Pump Station 4 (GW)SE1<4<40PFBA 5, PFHxA 3.1, PFPeA 3.2
2023-05-09Pump Station 5 (GW)SE1<4<40PFBA 5.5, PFHxA 3.2, PFPeA 3.2
2023-05-09Pump Station 6 (GW)SE1<4<40PFBA 6.3, PFPeA 3.3
2023-08-22Master Meter (SW)SE2n/an/an/anone
2023-11-20Master Meter (SW)SE3<4<40PFBA 5.8, PFHxA 3, PFPeA 3.5
2023-11-20Pump Station 4 (GW)SE2<4<40lithium 20.8 µg/L
2023-11-20Pump Station 5 (GW)SE2<4<40PFBA 6, PFHxA 3.1, PFPeA 3.9
2023-11-20Pump Station 6 (GW)SE2<4<40PFBA 5.5, PFPeA 3.1, lithium 20.6 µg/L
2024-02-28Master Meter (SW)SE4<4<40none
2024-07-29Master Meter (SW)SE2<4<40PFBA 5.4

“<4” = not detected at the reporting limit shown; “n/a” = not analyzed in that sample. Highlighted = at or above the 4 ppt MCL. HI computed per sample with non-detects as 0. Other detections lists every other quantified compound (lithium in µg/L).

All results by entry point

300 results. Each column is one sampling visit (date and UCMR 5 sample event). A number is a measured concentration; “< 4” = below the minimum reporting level shown; “–” = not analyzed in that visit. PFAS in ppt (ng/L); lithium in µg/L.

Master Meter facility 16617 · sample point EP001MC · surface water

CompoundMRL2023-05-09
SE1
2023-08-22
SE2
2023-11-20
SE3
2024-02-28
SE4
2024-07-29
SE2
PFBA5 ppt5.5–5.8< 55.4
PFHxA3 ppt< 3–3< 3< 3
PFPeA3 ppt3.1–3.5< 3< 3
11Cl-PF3OUdS5 ppt< 5–< 5< 5< 5
4:2 FTS3 ppt< 3–< 3< 3< 3
6:2 FTS5 ppt< 5–< 5< 5< 5
8:2 FTS5 ppt< 5–< 5< 5< 5
9Cl-PF3ONS2 ppt< 2–< 2< 2< 2
ADONA3 ppt< 3–< 3< 3< 3
HFPO-DA5 ppt< 5–< 5< 5< 5
NEtFOSAA5 ppt< 5< 5< 5< 5–
NFDHA20 ppt< 20–< 20< 20< 20
NMeFOSAA6 ppt< 6< 6< 6< 6–
PFBS3 ppt< 3–< 3< 3< 3
PFDA3 ppt< 3–< 3< 3< 3
PFDoA3 ppt< 3–< 3< 3< 3
PFEESA3 ppt< 3–< 3< 3< 3
PFHpA3 ppt< 3–< 3< 3< 3
PFHpS3 ppt< 3–< 3< 3< 3
PFHxS3 ppt< 3–< 3< 3< 3
PFMBA3 ppt< 3–< 3< 3< 3
PFMPA4 ppt< 4–< 4< 4< 4
PFNA4 ppt< 4–< 4< 4< 4
PFOA4 ppt< 4–< 4< 4< 4
PFOS4 ppt< 4–< 4< 4< 4
PFPeS4 ppt< 4–< 4< 4< 4
PFTA8 ppt< 8< 8< 8< 8–
PFTrDA7 ppt< 7< 7< 7< 7–
PFUnA2 ppt< 2–< 2< 2< 2
lithium9 µg/L< 9< 9< 9< 9–

Pump Station 4 facility 58370 · sample point EP005MC · groundwater

CompoundMRL2023-05-09
SE1
2023-11-20
SE2
PFBA5 ppt5< 5
PFHxA3 ppt3.1< 3
PFPeA3 ppt3.2< 3
11Cl-PF3OUdS5 ppt< 5< 5
4:2 FTS3 ppt< 3< 3
6:2 FTS5 ppt< 5< 5
8:2 FTS5 ppt< 5< 5
9Cl-PF3ONS2 ppt< 2< 2
ADONA3 ppt< 3< 3
HFPO-DA5 ppt< 5< 5
NEtFOSAA5 ppt< 5< 5
NFDHA20 ppt< 20< 20
NMeFOSAA6 ppt< 6< 6
PFBS3 ppt< 3< 3
PFDA3 ppt< 3< 3
PFDoA3 ppt< 3< 3
PFEESA3 ppt< 3< 3
PFHpA3 ppt< 3< 3
PFHpS3 ppt< 3< 3
PFHxS3 ppt< 3< 3
PFMBA3 ppt< 3< 3
PFMPA4 ppt< 4< 4
PFNA4 ppt< 4< 4
PFOA4 ppt< 4< 4
PFOS4 ppt< 4< 4
PFPeS4 ppt< 4< 4
PFTA8 ppt< 8< 8
PFTrDA7 ppt< 7< 7
PFUnA2 ppt< 2< 2
lithium9 µg/L< 920.8

Pump Station 5 facility 58367 · sample point EP006MC · groundwater

CompoundMRL2023-05-09
SE1
2023-11-20
SE2
PFBA5 ppt5.56
PFHxA3 ppt3.23.1
PFPeA3 ppt3.23.9
11Cl-PF3OUdS5 ppt< 5< 5
4:2 FTS3 ppt< 3< 3
6:2 FTS5 ppt< 5< 5
8:2 FTS5 ppt< 5< 5
9Cl-PF3ONS2 ppt< 2< 2
ADONA3 ppt< 3< 3
HFPO-DA5 ppt< 5< 5
NEtFOSAA5 ppt< 5< 5
NFDHA20 ppt< 20< 20
NMeFOSAA6 ppt< 6< 6
PFBS3 ppt< 3< 3
PFDA3 ppt< 3< 3
PFDoA3 ppt< 3< 3
PFEESA3 ppt< 3< 3
PFHpA3 ppt< 3< 3
PFHpS3 ppt< 3< 3
PFHxS3 ppt< 3< 3
PFMBA3 ppt< 3< 3
PFMPA4 ppt< 4< 4
PFNA4 ppt< 4< 4
PFOA4 ppt< 4< 4
PFOS4 ppt< 4< 4
PFPeS4 ppt< 4< 4
PFTA8 ppt< 8< 8
PFTrDA7 ppt< 7< 7
PFUnA2 ppt< 2< 2
lithium9 µg/L< 9< 9

Pump Station 6 facility 58368 · sample point EP007MC · groundwater

CompoundMRL2023-05-09
SE1
2023-11-20
SE2
PFBA5 ppt6.35.5
PFPeA3 ppt3.33.1
11Cl-PF3OUdS5 ppt< 5< 5
4:2 FTS3 ppt< 3< 3
6:2 FTS5 ppt< 5< 5
8:2 FTS5 ppt< 5< 5
9Cl-PF3ONS2 ppt< 2< 2
ADONA3 ppt< 3< 3
HFPO-DA5 ppt< 5< 5
NEtFOSAA5 ppt< 5< 5
NFDHA20 ppt< 20< 20
NMeFOSAA6 ppt< 6< 6
PFBS3 ppt< 3< 3
PFDA3 ppt< 3< 3
PFDoA3 ppt< 3< 3
PFEESA3 ppt< 3< 3
PFHpA3 ppt< 3< 3
PFHpS3 ppt< 3< 3
PFHxA3 ppt< 3< 3
PFHxS3 ppt< 3< 3
PFMBA3 ppt< 3< 3
PFMPA4 ppt< 4< 4
PFNA4 ppt< 4< 4
PFOA4 ppt< 4< 4
PFOS4 ppt< 4< 4
PFPeS4 ppt< 4< 4
PFTA8 ppt< 8< 8
PFTrDA7 ppt< 7< 7
PFUnA2 ppt< 2< 2
lithium9 µg/L< 920.6

Statistics by compound

CompoundResultsDetectedHighest (date)Mean boundsKM medianP75P90P95
PFBA1080%6.3
2023-05-09
4.5–5.55.55.866.3
PFPeA1070%3.9
2023-11-20
2.33–3.233.13.33.53.9
PFHxA1040%3.2
2023-05-09
1.24–3.04<MRL3.13.13.2
lithium1020%20.8
2023-11-20
4.14–11.34<MRL<MRL20.620.8

Never detected (26): 11Cl-PF3OUdS, 4:2 FTS, 6:2 FTS, 8:2 FTS, 9Cl-PF3ONS, ADONA, HFPO-DA, NEtFOSAA, NFDHA, NMeFOSAA, PFBS, PFDA, PFDoA, PFEESA, PFHpA, PFHpS, PFHxS, PFMBA, PFMPA, PFNA, PFOA, PFOS, PFPeS, PFTA, PFTrDA, PFUnA.

Left-censored Kaplan–Meier statistics (Helsel 2005; Helsel & Lee 2006, NADA for R). Units: ppt; lithium µg/L. Each compound has one reporting limit, so the Kaplan–Meier mean equals the upper mean bound (non-detects at the MRL); the lower bound sets non-detects to 0. “<MRL” = the percentile falls below the reporting limit and cannot be estimated. These describe this system's UCMR 5 samples, not population estimates.

Sources

  • EPA UCMR 5 occurrence data text files (UCMR5_All.txt; samples 2023-01-09 to 2026-06-16; data summary dated Jul 2026)
  • EPA SDWIS via ECHO SDWA downloads, quarter 2026Q3
  • EPA Public Water System Service Areas v3 (Mar 2026)
  • US Census Bureau cartographic boundary counties 1:500k, 2024
  • EPA/USGS NHDPlus V2 (medium resolution) flowlines, Strahler order 2+

Data build a6f3d99247ed · 2026-10-18T04:13Z · UCMR 5 release Jul2026 · SDWIS 2026Q3. Data and methods.