Hawley Wsc

PFAS monitoring results for a public water system in Texas

TX1270006UCMR 5EPA monitoring data
8.8Highest PFOA result, ppt
32.3Highest PFOS result, ppt
3.644Highest Hazard Index
480Results
PWSID
TX1270006
State
Texas
System type
community water system (CWS)
Population served
8,436
City
Hawley
Counties
Jones County, Taylor County
Primary source water
surface water (purchased)
UCMR 5 sampling
2024-01-17 to 2024-10-21 · 4 entry point(s) · water types: SW
Service-area boundary
authoritative

PFOS ≥ 3 × its limit highest single result
PFOS ≥ 3 × its limit worst entry-point average

These are monitoring results collected under EPA's Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) at entry points, where treated water enters the distribution system; they are not tap-water samples. They are not compliance determinations: compliance with EPA's 2024 PFAS limits is judged on running annual averages of compliance monitoring, required from 2029, so a single UCMR 5 result at or above a limit is not a violation. “< MRL” means the compound was not quantified at EPA's minimum reporting level; it does not mean zero.

Water purchased from

  • City Of Abilene (TX2210001)
    Seller's highest results: PFOA 7.7 ppt · PFOS 30 ppt · HI 3.244 · detected: PFBA;PFBS;PFHpA;PFHxA;PFHxS;PFOA;PFOS;PFPeA;PFPeS
  • City Of Anson (TX1270001)
    Seller not monitored under UCMR 5.

Seller results are the seller's own entry-point samples, not measurements of this system's water. This system's own samples (below) may reflect purchased water, its own sources, or both.

Compared with EPA's 2024 values

Highest single resultWorst entry-point average*Limit
PFOA (ppt)8.85.254
PFOS (ppt)32.320.934
Hazard Index3.6442.3061.0†

“<MRL” = every result for the compound was below its reporting limit. * Mean of all samples at each entry point with non-detects = 0 (EPA compliance convention; the Hazard Index also uses non-detects = 0); a screening comparison, not a formal running annual average. † Rescission proposed May 2026. PFOA/PFOS MCL 4 ppt (2024 NPDWR, in effect). PFHxS, PFNA, HFPO-DA (10 ppt each) and the Hazard Index (1.0) are 2024 NPDWR values; EPA proposed rescinding them on 18 May 2026 (comment period closed 20 Jul 2026).

No Texas PFAS drinking-water standard in effect or proposed as of 2026-10-17: No state PFAS drinking-water standard; TCEQ implementing federal NPDWR (BCLP state survey, Jan 2026).

Sampling history

Sampled 2024-01-17 to 2024-10-21 · 4 entry point(s) · water types: SW · 16 sampling visits. PFAS in ppt (ng/L).

DateEntry pointEventPFOAPFOSHIOther detections
2024-01-17HAWLEY WSC (SW)SE18.832.33.644PFBA 21.6, PFHpA 11.9, PFHxA 26.8, PFPeA 21.9, PFPeS 5, lithium 12.7 µg/L
2024-01-17HAWLEY WSC (SW)SE18.632.13.595PFBA 21.8, PFHpA 11.6, PFHxA 26.9, PFPeA 22.7, PFPeS 4.9, lithium 11.4 µg/L
2024-01-17HAWLEY WSC (SW)SE18.519.73.525PFBA 20.9, PFHpA 11.6, PFHxA 27.1, PFPeA 21.9, PFPeS 4.7, lithium 12.5 µg/L
2024-01-17HAWLEY WSC (SW)SE1<4<40PFBA 17.3, lithium 12.7 µg/L
2024-04-24HAWLEY WSC (SW)SE25.415.52.363PFBA 13.4, PFHpA 7.4, PFHxA 15.8, PFPeA 12.6, lithium 12.1 µg/L
2024-04-24HAWLEY WSC (SW)SE24.914.12.063PFBA 14, PFHpA 6.3, PFHxA 14.4, PFPeA 11.4, lithium 12.6 µg/L
2024-04-24HAWLEY WSC (SW)SE25.3162.323PFBA 13, PFHpA 7.3, PFHxA 15.3, PFPeA 12.5, lithium 11.4 µg/L
2024-04-24HAWLEY WSC (SW)SE2<4<40PFBA 7.4, lithium 12.7 µg/L
2024-07-23HAWLEY WSC (SW)SE3<412.21.262PFBA 11.1, PFHpA 4.7, PFHxA 9.2, PFPeA 8, lithium 13.3 µg/L
2024-07-23HAWLEY WSC (SW)SE3<49.40.921PFBA 11.3, PFHpA 3.6, PFHxA 7, PFPeA 6, lithium 13.3 µg/L
2024-07-23HAWLEY WSC (SW)SE3<411.11.262PFBA 12.6, PFHpA 4.7, PFHxA 9.2, PFPeA 7.7, lithium 12.7 µg/L
2024-07-23HAWLEY WSC (SW)SE3<4<40lithium 13.4 µg/L
2024-10-21HAWLEY WSC (SW)SE46.823.71.953PFBA 14.7, PFHpA 7.3, PFHxA 14.4, PFPeA 13.2, lithium 12.4 µg/L
2024-10-21HAWLEY WSC (SW)SE46.722.81.903PFBA 15.2, PFHpA 7.5, PFHxA 25.5, PFPeA 14, lithium 12.4 µg/L
2024-10-21HAWLEY WSC (SW)SE46.823.41.973PFBA 15.1, PFHpA 7.7, PFHxA 14.2, PFPeA 13.7, lithium 12.5 µg/L
2024-10-21HAWLEY WSC (SW)SE4<4<40lithium 12.9 µg/L

“<4” = not detected at the reporting limit shown; “n/a” = not analyzed in that sample. Highlighted = at or above the 4 ppt MCL. HI computed per sample with non-detects as 0. Other detections lists every other quantified compound (lithium in µg/L).

All results by entry point

480 results. Each column is one sampling visit (date and UCMR 5 sample event). A number is a measured concentration; “< 4” = below the minimum reporting level shown; “–” = not analyzed in that visit. PFAS in ppt (ng/L); lithium in µg/L.

HAWLEY WSC facility EP001 · sample point TRTTAP · surface water

CompoundMRL2024-01-17
SE1
2024-04-24
SE2
2024-07-23
SE3
2024-10-21
SE4
PFBA5 ppt21.613.411.114.7
PFBS3 ppt8.85.73.76.2
PFHpA3 ppt11.97.44.77.3
PFHxA3 ppt26.815.89.214.4
PFHxS3 ppt36.423.612.619.5
PFOA4 ppt8.85.4< 46.8
PFOS4 ppt32.315.512.223.7
PFPeA3 ppt21.912.6813.2
PFPeS4 ppt5< 4< 4< 4
11Cl-PF3OUdS5 ppt< 5< 5< 5< 5
4:2 FTS3 ppt< 3< 3< 3< 3
6:2 FTS5 ppt< 5< 5< 5< 5
8:2 FTS5 ppt< 5< 5< 5< 5
9Cl-PF3ONS2 ppt< 2< 2< 2< 2
ADONA3 ppt< 3< 3< 3< 3
HFPO-DA5 ppt< 5< 5< 5< 5
NEtFOSAA5 ppt< 5< 5< 5< 5
NFDHA20 ppt< 20< 20< 20< 20
NMeFOSAA6 ppt< 6< 6< 6< 6
PFDA3 ppt< 3< 3< 3< 3
PFDoA3 ppt< 3< 3< 3< 3
PFEESA3 ppt< 3< 3< 3< 3
PFHpS3 ppt< 3< 3< 3< 3
PFMBA3 ppt< 3< 3< 3< 3
PFMPA4 ppt< 4< 4< 4< 4
PFNA4 ppt< 4< 4< 4< 4
PFTA8 ppt< 8< 8< 8< 8
PFTrDA7 ppt< 7< 7< 7< 7
PFUnA2 ppt< 2< 2< 2< 2
lithium9 µg/L12.712.113.312.4

HAWLEY WSC facility EP002 · sample point TRTTAP · surface water

CompoundMRL2024-01-17
SE1
2024-04-24
SE2
2024-07-23
SE3
2024-10-21
SE4
PFBA5 ppt21.81411.315.2
PFBS3 ppt9.55.436.2
PFHpA3 ppt11.66.33.67.5
PFHxA3 ppt26.914.4725.5
PFHxS3 ppt35.920.69.219
PFOA4 ppt8.64.9< 46.7
PFOS4 ppt32.114.19.422.8
PFPeA3 ppt22.711.4614
PFPeS4 ppt4.9< 4< 4< 4
11Cl-PF3OUdS5 ppt< 5< 5< 5< 5
4:2 FTS3 ppt< 3< 3< 3< 3
6:2 FTS5 ppt< 5< 5< 5< 5
8:2 FTS5 ppt< 5< 5< 5< 5
9Cl-PF3ONS2 ppt< 2< 2< 2< 2
ADONA3 ppt< 3< 3< 3< 3
HFPO-DA5 ppt< 5< 5< 5< 5
NEtFOSAA5 ppt< 5< 5< 5< 5
NFDHA20 ppt< 20< 20< 20< 20
NMeFOSAA6 ppt< 6< 6< 6< 6
PFDA3 ppt< 3< 3< 3< 3
PFDoA3 ppt< 3< 3< 3< 3
PFEESA3 ppt< 3< 3< 3< 3
PFHpS3 ppt< 3< 3< 3< 3
PFMBA3 ppt< 3< 3< 3< 3
PFMPA4 ppt< 4< 4< 4< 4
PFNA4 ppt< 4< 4< 4< 4
PFTA8 ppt< 8< 8< 8< 8
PFTrDA7 ppt< 7< 7< 7< 7
PFUnA2 ppt< 2< 2< 2< 2
lithium9 µg/L11.412.613.312.4

HAWLEY WSC facility EP003 · sample point TRTTAP · surface water

CompoundMRL2024-01-17
SE1
2024-04-24
SE2
2024-07-23
SE3
2024-10-21
SE4
PFBA5 ppt20.91312.615.1
PFBS3 ppt9.15.73.66.2
PFHpA3 ppt11.67.34.77.7
PFHxA3 ppt27.115.39.214.2
PFHxS3 ppt35.223.212.619.7
PFOA4 ppt8.55.3< 46.8
PFOS4 ppt19.71611.123.4
PFPeA3 ppt21.912.57.713.7
PFPeS4 ppt4.7< 4< 4< 4
11Cl-PF3OUdS5 ppt< 5< 5< 5< 5
4:2 FTS3 ppt< 3< 3< 3< 3
6:2 FTS5 ppt< 5< 5< 5< 5
8:2 FTS5 ppt< 5< 5< 5< 5
9Cl-PF3ONS2 ppt< 2< 2< 2< 2
ADONA3 ppt< 3< 3< 3< 3
HFPO-DA5 ppt< 5< 5< 5< 5
NEtFOSAA5 ppt< 5< 5< 5< 5
NFDHA20 ppt< 20< 20< 20< 20
NMeFOSAA6 ppt< 6< 6< 6< 6
PFDA3 ppt< 3< 3< 3< 3
PFDoA3 ppt< 3< 3< 3< 3
PFEESA3 ppt< 3< 3< 3< 3
PFHpS3 ppt< 3< 3< 3< 3
PFMBA3 ppt< 3< 3< 3< 3
PFMPA4 ppt< 4< 4< 4< 4
PFNA4 ppt< 4< 4< 4< 4
PFTA8 ppt< 8< 8< 8< 8
PFTrDA7 ppt< 7< 7< 7< 7
PFUnA2 ppt< 2< 2< 2< 2
lithium9 µg/L12.511.412.712.5

HAWLEY WSC facility EP006 · sample point TRTTAP · surface water

CompoundMRL2024-01-17
SE1
2024-04-24
SE2
2024-07-23
SE3
2024-10-21
SE4
PFBA5 ppt17.37.4< 5< 5
11Cl-PF3OUdS5 ppt< 5< 5< 5< 5
4:2 FTS3 ppt< 3< 3< 3< 3
6:2 FTS5 ppt< 5< 5< 5< 5
8:2 FTS5 ppt< 5< 5< 5< 5
9Cl-PF3ONS2 ppt< 2< 2< 2< 2
ADONA3 ppt< 3< 3< 3< 3
HFPO-DA5 ppt< 5< 5< 5< 5
NEtFOSAA5 ppt< 5< 5< 5< 5
NFDHA20 ppt< 20< 20< 20< 20
NMeFOSAA6 ppt< 6< 6< 6< 6
PFBS3 ppt< 3< 3< 3< 3
PFDA3 ppt< 3< 3< 3< 3
PFDoA3 ppt< 3< 3< 3< 3
PFEESA3 ppt< 3< 3< 3< 3
PFHpA3 ppt< 3< 3< 3< 3
PFHpS3 ppt< 3< 3< 3< 3
PFHxA3 ppt< 3< 3< 3< 3
PFHxS3 ppt< 3< 3< 3< 3
PFMBA3 ppt< 3< 3< 3< 3
PFMPA4 ppt< 4< 4< 4< 4
PFNA4 ppt< 4< 4< 4< 4
PFOA4 ppt< 4< 4< 4< 4
PFOS4 ppt< 4< 4< 4< 4
PFPeA3 ppt< 3< 3< 3< 3
PFPeS4 ppt< 4< 4< 4< 4
PFTA8 ppt< 8< 8< 8< 8
PFTrDA7 ppt< 7< 7< 7< 7
PFUnA2 ppt< 2< 2< 2< 2
lithium9 µg/L12.712.713.412.9

Statistics by compound

CompoundResultsDetectedHighest (date)Mean boundsKM medianP75P90P95
lithium16100%13.4
2024-07-23
12.56–12.5612.612.713.313.4
PFBA1688%21.8
2024-01-17
13.09–13.7113.415.221.621.8
PFBS1675%9.5
2024-01-17
4.57–5.325.46.29.19.5
PFHpA1675%11.9
2024-01-17
5.72–6.476.37.511.611.9
PFHxA1675%27.1
2024-01-17
12.86–13.6114.215.826.927.1
PFHxS1675%36.4
2024-01-17
16.72–17.471923.235.936.4
PFOS1675%32.3
2024-01-17
14.52–15.5214.122.832.132.3
PFPeA1675%22.7
2024-01-17
10.35–11.111.413.721.922.7
PFOA1656%8.8
2024-01-17
3.86–5.614.96.88.68.8
PFPeS1619%5
2024-01-17
0.91–4.16<MRL<MRL4.95

Never detected (20): 11Cl-PF3OUdS, 4:2 FTS, 6:2 FTS, 8:2 FTS, 9Cl-PF3ONS, ADONA, HFPO-DA, NEtFOSAA, NFDHA, NMeFOSAA, PFDA, PFDoA, PFEESA, PFHpS, PFMBA, PFMPA, PFNA, PFTA, PFTrDA, PFUnA.

Left-censored Kaplan–Meier statistics (Helsel 2005; Helsel & Lee 2006, NADA for R). Units: ppt; lithium µg/L. Each compound has one reporting limit, so the Kaplan–Meier mean equals the upper mean bound (non-detects at the MRL); the lower bound sets non-detects to 0. “<MRL” = the percentile falls below the reporting limit and cannot be estimated. These describe this system's UCMR 5 samples, not population estimates.

Sources

  • EPA UCMR 5 occurrence data text files (UCMR5_All.txt; samples 2023-01-09 to 2026-06-16; data summary dated Jul 2026)
  • EPA SDWIS via ECHO SDWA downloads, quarter 2026Q3
  • EPA Public Water System Service Areas v3 (Mar 2026)
  • US Census Bureau cartographic boundary counties 1:500k, 2024
  • EPA/USGS NHDPlus V2 (medium resolution) flowlines, Strahler order 2+

Data build a6f3d99247ed · 2026-10-18T04:13Z · UCMR 5 release Jul2026 · SDWIS 2026Q3. Data and methods.