City Of Abilene

PFAS monitoring results for a public water system in Texas

TX2210001UCMR 5EPA monitoring data
7.7Highest PFOA result, ppt
30Highest PFOS result, ppt
3.244Highest Hazard Index
360Results
PWSID
TX2210001
State
Texas
System type
community water system (CWS)
Population served
130,501
City
Abilene
Counties
Taylor County
Primary source water
surface water
UCMR 5 sampling
2023-09-13 to 2024-06-27 · 3 entry point(s) · water types: SW
Service-area boundary
authoritative

PFOS ≥ 3 × its limit highest single result
PFOS ≥ 3 × its limit worst entry-point average

These are monitoring results collected under EPA's Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) at entry points, where treated water enters the distribution system; they are not tap-water samples. They are not compliance determinations: compliance with EPA's 2024 PFAS limits is judged on running annual averages of compliance monitoring, required from 2029, so a single UCMR 5 result at or above a limit is not a violation. “< MRL” means the compound was not quantified at EPA's minimum reporting level; it does not mean zero.

Water purchased from

Seller results are the seller's own entry-point samples, not measurements of this system's water. This system's own samples (below) may reflect purchased water, its own sources, or both.

Compared with EPA's 2024 values

Highest single resultWorst entry-point average*Limit
PFOA (ppt)7.76.854
PFOS (ppt)3025.274
Hazard Index3.2442.6111.0†

“<MRL” = every result for the compound was below its reporting limit. * Mean of all samples at each entry point with non-detects = 0 (EPA compliance convention; the Hazard Index also uses non-detects = 0); a screening comparison, not a formal running annual average. † Rescission proposed May 2026. PFOA/PFOS MCL 4 ppt (2024 NPDWR, in effect). PFHxS, PFNA, HFPO-DA (10 ppt each) and the Hazard Index (1.0) are 2024 NPDWR values; EPA proposed rescinding them on 18 May 2026 (comment period closed 20 Jul 2026).

No Texas PFAS drinking-water standard in effect or proposed as of 2026-10-17: No state PFAS drinking-water standard; TCEQ implementing federal NPDWR (BCLP state survey, Jan 2026).

Sampling history

Sampled 2023-09-13 to 2024-06-27 · 3 entry point(s) · water types: SW · 16 sampling visits. PFAS in ppt (ng/L).

DateEntry pointEventPFOAPFOSHIOther detections
2023-09-13Grimes/Northwest WTP (SW)SE16.123.82.293PFBA 12.7, PFHpA 8.1, PFHxA 17.6, PFPeA 14, lithium 11.2 µg/L
2023-09-13Hargesheimer/Southside WTP (SW)SE1<4<40.904PFBA 6.5, PFHxA 3.1, lithium 48.1 µg/L
2023-09-13Northeast Plant (SW)SE17.5302.794PFBA 14.3, PFHpA 10, PFHxA 21.7, PFPeA 17.7, lithium 12 µg/L
2023-12-13Grimes/Northwest WTP (SW)SE2n/an/an/anone
2023-12-13Hargesheimer/Southside WTP (SW)SE2n/an/an/alithium 26.9 µg/L
2023-12-13Northeast Plant (SW)SE2n/an/an/alithium 10.8 µg/L
2024-02-21Grimes/Northwest WTP (SW)SE27.528.13.244PFBA 43.1, PFHpA 12, PFHxA 23.5, PFPeA 22.4, PFPeS 4.3
2024-02-21Hargesheimer/Southside WTP (SW)SE2<4<40.472PFBA 19.4
2024-02-21Northeast Plant (SW)SE27.728.93.244PFBA 22.2, PFHpA 12.4, PFHxA 23.4, PFPeA 22.9, PFPeS 4.5
2024-03-27Grimes/Northwest WTP (SW)SE35.7202.023PFBA 14.6, PFHpA 7.1, PFHxA 19.1, PFPeA 15.8, lithium 9.5 µg/L
2024-03-27Hargesheimer/Southside WTP (SW)SE3<4<40.683PFBA 7.5, lithium 28.9 µg/L
2024-03-27Northeast Plant (SW)SE35.116.61.783PFBA 14, PFHpA 7, PFHxA 14, PFPeA 12, lithium 9.6 µg/L
2024-06-12Grimes/Northwest WTP (SW)SE46.923.32.523PFBA 16.7, PFHpA 9, PFHxA 20.5, PFPeA 16.1, lithium 9.5 µg/L
2024-06-12Hargesheimer/Southside WTP (SW)SE4<4<40lithium 16.3 µg/L
2024-06-12Northeast Plant (SW)SE47.125.62.623PFBA 16.9, PFHpA 9.6, PFHxA 21.4, PFPeA 16.4, lithium 10.3 µg/L
2024-06-27Northeast Plant (SW)SE4n/an/an/anone

“<4” = not detected at the reporting limit shown; “n/a” = not analyzed in that sample. Highlighted = at or above the 4 ppt MCL. HI computed per sample with non-detects as 0. Other detections lists every other quantified compound (lithium in µg/L).

All results by entry point

360 results. Each column is one sampling visit (date and UCMR 5 sample event). A number is a measured concentration; “< 4” = below the minimum reporting level shown; “–” = not analyzed in that visit. PFAS in ppt (ng/L); lithium in µg/L.

Grimes/Northwest WTP facility 58564 · sample point EP003MC3 · surface water

CompoundMRL2023-09-13
SE1
2023-12-13
SE2
2024-02-21
SE2
2024-03-27
SE3
2024-06-12
SE4
PFBA5 ppt12.7–43.114.616.7
PFBS3 ppt6.2–8.25.66.7
PFHpA3 ppt8.1–127.19
PFHxA3 ppt17.6–23.519.120.5
PFHxS3 ppt22.9–32.420.225.2
PFOA4 ppt6.1–7.55.76.9
PFOS4 ppt23.8–28.12023.3
PFPeA3 ppt14–22.415.816.1
PFPeS4 ppt< 4–4.3< 4< 4
11Cl-PF3OUdS5 ppt< 5–< 5< 5< 5
4:2 FTS3 ppt< 3–< 3< 3< 3
6:2 FTS5 ppt< 5–< 5< 5< 5
8:2 FTS5 ppt< 5–< 5< 5< 5
9Cl-PF3ONS2 ppt< 2–< 2< 2< 2
ADONA3 ppt< 3–< 3< 3< 3
HFPO-DA5 ppt< 5–< 5< 5< 5
NEtFOSAA5 ppt< 5< 5–< 5< 5
NFDHA20 ppt< 20–< 20< 20< 20
NMeFOSAA6 ppt< 6< 6–< 6< 6
PFDA3 ppt< 3–< 3< 3< 3
PFDoA3 ppt< 3–< 3< 3< 3
PFEESA3 ppt< 3–< 3< 3< 3
PFHpS3 ppt< 3–< 3< 3< 3
PFMBA3 ppt< 3–< 3< 3< 3
PFMPA4 ppt< 4–< 4< 4< 4
PFNA4 ppt< 4–< 4< 4< 4
PFTA8 ppt< 8< 8–< 8< 8
PFTrDA7 ppt< 7< 7–< 7< 7
PFUnA2 ppt< 2–< 2< 2< 2
lithium9 µg/L11.2< 9–9.59.5

Hargesheimer/Southside WTP facility 61999 · sample point EP004MC4 · surface water

CompoundMRL2023-09-13
SE1
2023-12-13
SE2
2024-02-21
SE2
2024-03-27
SE3
2024-06-12
SE4
PFBA5 ppt6.5–19.47.5< 5
PFBS3 ppt7.4–4.36.4< 3
PFHxA3 ppt3.1–< 3< 3< 3
PFHxS3 ppt9–4.76.8< 3
11Cl-PF3OUdS5 ppt< 5–< 5< 5< 5
4:2 FTS3 ppt< 3–< 3< 3< 3
6:2 FTS5 ppt< 5–< 5< 5< 5
8:2 FTS5 ppt< 5–< 5< 5< 5
9Cl-PF3ONS2 ppt< 2–< 2< 2< 2
ADONA3 ppt< 3–< 3< 3< 3
HFPO-DA5 ppt< 5–< 5< 5< 5
NEtFOSAA5 ppt< 5< 5–< 5< 5
NFDHA20 ppt< 20–< 20< 20< 20
NMeFOSAA6 ppt< 6< 6–< 6< 6
PFDA3 ppt< 3–< 3< 3< 3
PFDoA3 ppt< 3–< 3< 3< 3
PFEESA3 ppt< 3–< 3< 3< 3
PFHpA3 ppt< 3–< 3< 3< 3
PFHpS3 ppt< 3–< 3< 3< 3
PFMBA3 ppt< 3–< 3< 3< 3
PFMPA4 ppt< 4–< 4< 4< 4
PFNA4 ppt< 4–< 4< 4< 4
PFOA4 ppt< 4–< 4< 4< 4
PFOS4 ppt< 4–< 4< 4< 4
PFPeA3 ppt< 3–< 3< 3< 3
PFPeS4 ppt< 4–< 4< 4< 4
PFTA8 ppt< 8< 8–< 8< 8
PFTrDA7 ppt< 7< 7–< 7< 7
PFUnA2 ppt< 2–< 2< 2< 2
lithium9 µg/L48.126.9–28.916.3

Northeast Plant facility 58563 · sample point EP002MC2 · surface water

CompoundMRL2023-09-13
SE1
2023-12-13
SE2
2024-02-21
SE2
2024-03-27
SE3
2024-06-12
SE4
2024-06-27
SE4
PFBA5 ppt14.3–22.21416.9–
PFBS3 ppt7.4–8.25.16.9–
PFHpA3 ppt10–12.479.6–
PFHxA3 ppt21.7–23.41421.4–
PFHxS3 ppt27.9–32.417.826.2–
PFOA4 ppt7.5–7.75.17.1–
PFOS4 ppt30–28.916.625.6–
PFPeA3 ppt17.7–22.91216.4–
PFPeS4 ppt< 4–4.5< 4< 4–
11Cl-PF3OUdS5 ppt< 5–< 5< 5< 5–
4:2 FTS3 ppt< 3–< 3< 3< 3–
6:2 FTS5 ppt< 5–< 5< 5< 5–
8:2 FTS5 ppt< 5–< 5< 5< 5–
9Cl-PF3ONS2 ppt< 2–< 2< 2< 2–
ADONA3 ppt< 3–< 3< 3< 3–
HFPO-DA5 ppt< 5–< 5< 5< 5–
NEtFOSAA5 ppt< 5< 5–< 5–< 5
NFDHA20 ppt< 20–< 20< 20< 20–
NMeFOSAA6 ppt< 6< 6–< 6–< 6
PFDA3 ppt< 3–< 3< 3< 3–
PFDoA3 ppt< 3–< 3< 3< 3–
PFEESA3 ppt< 3–< 3< 3< 3–
PFHpS3 ppt< 3–< 3< 3< 3–
PFMBA3 ppt< 3–< 3< 3< 3–
PFMPA4 ppt< 4–< 4< 4< 4–
PFNA4 ppt< 4–< 4< 4< 4–
PFTA8 ppt< 8< 8–< 8–< 8
PFTrDA7 ppt< 7< 7–< 7–< 7
PFUnA2 ppt< 2–< 2< 2< 2–
lithium9 µg/L1210.8–9.610.3–

Statistics by compound

CompoundResultsDetectedHighest (date)Mean boundsKM medianP75P90P95
PFBA1292%43.1
2024-02-21
15.66–16.0714.316.922.243.1
PFBS1292%8.2
2024-02-21
6.03–6.286.47.48.28.2
PFHxS1292%32.4
2024-02-21
18.79–19.0420.226.232.432.4
lithium1292%48.1
2023-09-13
16.09–16.8410.816.328.948.1
PFHxA1275%23.5
2024-02-21
13.69–14.4417.621.423.423.5
PFHpA1267%12.4
2024-02-21
6.27–7.277.19.61212.4
PFOA1267%7.7
2024-02-21
4.47–5.85.77.17.57.7
PFOS1267%30
2023-09-13
16.36–17.692025.628.930
PFPeA1267%22.9
2024-02-21
11.44–12.441416.422.422.9
PFPeS1217%4.5
2024-02-21
0.73–4.07<MRL<MRL4.34.5

Never detected (20): 11Cl-PF3OUdS, 4:2 FTS, 6:2 FTS, 8:2 FTS, 9Cl-PF3ONS, ADONA, HFPO-DA, NEtFOSAA, NFDHA, NMeFOSAA, PFDA, PFDoA, PFEESA, PFHpS, PFMBA, PFMPA, PFNA, PFTA, PFTrDA, PFUnA.

Left-censored Kaplan–Meier statistics (Helsel 2005; Helsel & Lee 2006, NADA for R). Units: ppt; lithium µg/L. Each compound has one reporting limit, so the Kaplan–Meier mean equals the upper mean bound (non-detects at the MRL); the lower bound sets non-detects to 0. “<MRL” = the percentile falls below the reporting limit and cannot be estimated. These describe this system's UCMR 5 samples, not population estimates.

Sources

  • EPA UCMR 5 occurrence data text files (UCMR5_All.txt; samples 2023-01-09 to 2026-06-16; data summary dated Jul 2026)
  • EPA SDWIS via ECHO SDWA downloads, quarter 2026Q3
  • EPA Public Water System Service Areas v3 (Mar 2026)
  • US Census Bureau cartographic boundary counties 1:500k, 2024
  • EPA/USGS NHDPlus V2 (medium resolution) flowlines, Strahler order 2+

Data build a6f3d99247ed · 2026-10-18T04:13Z · UCMR 5 release Jul2026 · SDWIS 2026Q3. Data and methods.