East Peoria

PFAS monitoring results for a public water system in Illinois

IL1790200UCMR 5EPA monitoring data
<MRLHighest PFOA result, ppt
4.2Highest PFOS result, ppt
0.414Highest Hazard Index
360Results
PWSID
IL1790200
State
Illinois
System type
community water system (CWS)
Population served
22,484
City
East Peoria
Counties
Tazewell County
Primary source water
groundwater
UCMR 5 sampling
2023-09-05 to 2024-03-01 · 6 entry point(s) · water types: GW
Service-area boundary
EPA-modeled (Random Forest) — approximate: estimated by EPA with a statistical model, not a surveyed service area

PFOS 1–3 × its limit highest single result
PFOS below its limit worst entry-point average

These are monitoring results collected under EPA's Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) at entry points, where treated water enters the distribution system; they are not tap-water samples. They are not compliance determinations: compliance with EPA's 2024 PFAS limits is judged on running annual averages of compliance monitoring, required from 2029, so a single UCMR 5 result at or above a limit is not a violation. “< MRL” means the compound was not quantified at EPA's minimum reporting level; it does not mean zero.

Compared with EPA's 2024 values

Highest single resultWorst entry-point average*Limit
PFOA (ppt)<MRL04
PFOS (ppt)4.22.14
Hazard Index0.4140.3821.0†

“<MRL” = every result for the compound was below its reporting limit. * Mean of all samples at each entry point with non-detects = 0 (EPA compliance convention; the Hazard Index also uses non-detects = 0); a screening comparison, not a formal running annual average. † Rescission proposed May 2026. PFOA/PFOS MCL 4 ppt (2024 NPDWR, in effect). PFHxS, PFNA, HFPO-DA (10 ppt each) and the Hazard Index (1.0) are 2024 NPDWR values; EPA proposed rescinding them on 18 May 2026 (comment period closed 20 Jul 2026).

Compared with Illinois standards

Highest single resultWorst entry-point average*Illinois
PFOA (ppt)004
PFOS (ppt)4.22.14
PFNA (ppt)0010
PFHxS (ppt)4.13.810
HFPO-DA (GenX) (ppt)0010

Sum standards add the listed compounds within each sample (non-detects = 0). State compliance is normally judged on averages over time; these are screening comparisons.

Sampling history

Sampled 2023-09-05 to 2024-03-01 · 6 entry point(s) · water types: GW · 14 sampling visits. PFAS in ppt (ng/L).

DateEntry pointEventPFOAPFOSHIOther detections
2023-09-05CATHERINE (GW)SE1n/an/an/anone
2023-09-05CENTENNIAL FILTER PLANT (GW)SE1<4<40none
2023-09-05MEADOWS FILTER PLANT (GW)SE1<4<40none
2023-09-05NORTH MAIN FILTER PLANT (GW)SE1<4<40none
2023-09-05OAKWOOD FILTER PLANT (GW)SE1<4<40.412none
2023-09-05WELL 8 TAP (GW)SE1n/an/an/anone
2023-11-20CATHERINE (GW)SE1<44.20.414PFPeA 3
2023-11-20WELL 8 TAP (GW)SE1<4<40none
2024-03-01CATHERINE (GW)SE2<4<40.003none
2024-03-01CENTENNIAL FILTER PLANT (GW)SE2<4<40none
2024-03-01MEADOWS FILTER PLANT (GW)SE2<4<40none
2024-03-01NORTH MAIN FILTER PLANT (GW)SE2<4<40none
2024-03-01OAKWOOD FILTER PLANT (GW)SE2<4<40.352none
2024-03-01WELL 8 TAP (GW)SE2<4<40.003none

“<4” = not detected at the reporting limit shown; “n/a” = not analyzed in that sample. Highlighted = at or above the 4 ppt MCL. HI computed per sample with non-detects as 0. Other detections lists every other quantified compound (lithium in µg/L).

All results by entry point

360 results. Each column is one sampling visit (date and UCMR 5 sample event). A number is a measured concentration; “< 4” = below the minimum reporting level shown; “–” = not analyzed in that visit. PFAS in ppt (ng/L); lithium in µg/L.

CATHERINE facility TP03 · sample point TP03 · groundwater

CompoundMRL2023-09-05
SE1
2023-11-20
SE1
2024-03-01
SE2
PFBS3 ppt–7.35
PFHxS3 ppt–4.1< 3
PFOS4 ppt–4.2< 4
PFPeA3 ppt–3< 3
11Cl-PF3OUdS5 ppt–< 5< 5
4:2 FTS3 ppt–< 3< 3
6:2 FTS5 ppt–< 5< 5
8:2 FTS5 ppt–< 5< 5
9Cl-PF3ONS2 ppt–< 2< 2
ADONA3 ppt–< 3< 3
HFPO-DA5 ppt–< 5< 5
NEtFOSAA5 ppt< 5–< 5
NFDHA20 ppt–< 20< 20
NMeFOSAA6 ppt< 6–< 6
PFBA5 ppt–< 5< 5
PFDA3 ppt–< 3< 3
PFDoA3 ppt–< 3< 3
PFEESA3 ppt–< 3< 3
PFHpA3 ppt–< 3< 3
PFHpS3 ppt–< 3< 3
PFHxA3 ppt–< 3< 3
PFMBA3 ppt–< 3< 3
PFMPA4 ppt–< 4< 4
PFNA4 ppt–< 4< 4
PFOA4 ppt–< 4< 4
PFPeS4 ppt–< 4< 4
PFTA8 ppt< 8–< 8
PFTrDA7 ppt< 7–< 7
PFUnA2 ppt–< 2< 2
lithium9 µg/L< 9–< 9

CENTENNIAL FILTER PLANT facility TP11 · sample point TP11 · groundwater

CompoundMRL2023-09-05
SE1
2024-03-01
SE2
11Cl-PF3OUdS5 ppt< 5< 5
4:2 FTS3 ppt< 3< 3
6:2 FTS5 ppt< 5< 5
8:2 FTS5 ppt< 5< 5
9Cl-PF3ONS2 ppt< 2< 2
ADONA3 ppt< 3< 3
HFPO-DA5 ppt< 5< 5
NEtFOSAA5 ppt< 5< 5
NFDHA20 ppt< 20< 20
NMeFOSAA6 ppt< 6< 6
PFBA5 ppt< 5< 5
PFBS3 ppt< 3< 3
PFDA3 ppt< 3< 3
PFDoA3 ppt< 3< 3
PFEESA3 ppt< 3< 3
PFHpA3 ppt< 3< 3
PFHpS3 ppt< 3< 3
PFHxA3 ppt< 3< 3
PFHxS3 ppt< 3< 3
PFMBA3 ppt< 3< 3
PFMPA4 ppt< 4< 4
PFNA4 ppt< 4< 4
PFOA4 ppt< 4< 4
PFOS4 ppt< 4< 4
PFPeA3 ppt< 3< 3
PFPeS4 ppt< 4< 4
PFTA8 ppt< 8< 8
PFTrDA7 ppt< 7< 7
PFUnA2 ppt< 2< 2
lithium9 µg/L< 9< 9

MEADOWS FILTER PLANT facility TP06 · sample point TP06 · groundwater

CompoundMRL2023-09-05
SE1
2024-03-01
SE2
11Cl-PF3OUdS5 ppt< 5< 5
4:2 FTS3 ppt< 3< 3
6:2 FTS5 ppt< 5< 5
8:2 FTS5 ppt< 5< 5
9Cl-PF3ONS2 ppt< 2< 2
ADONA3 ppt< 3< 3
HFPO-DA5 ppt< 5< 5
NEtFOSAA5 ppt< 5< 5
NFDHA20 ppt< 20< 20
NMeFOSAA6 ppt< 6< 6
PFBA5 ppt< 5< 5
PFBS3 ppt< 3< 3
PFDA3 ppt< 3< 3
PFDoA3 ppt< 3< 3
PFEESA3 ppt< 3< 3
PFHpA3 ppt< 3< 3
PFHpS3 ppt< 3< 3
PFHxA3 ppt< 3< 3
PFHxS3 ppt< 3< 3
PFMBA3 ppt< 3< 3
PFMPA4 ppt< 4< 4
PFNA4 ppt< 4< 4
PFOA4 ppt< 4< 4
PFOS4 ppt< 4< 4
PFPeA3 ppt< 3< 3
PFPeS4 ppt< 4< 4
PFTA8 ppt< 8< 8
PFTrDA7 ppt< 7< 7
PFUnA2 ppt< 2< 2
lithium9 µg/L< 9< 9

NORTH MAIN FILTER PLANT facility TP07 · sample point TP07 · groundwater

CompoundMRL2023-09-05
SE1
2024-03-01
SE2
11Cl-PF3OUdS5 ppt< 5< 5
4:2 FTS3 ppt< 3< 3
6:2 FTS5 ppt< 5< 5
8:2 FTS5 ppt< 5< 5
9Cl-PF3ONS2 ppt< 2< 2
ADONA3 ppt< 3< 3
HFPO-DA5 ppt< 5< 5
NEtFOSAA5 ppt< 5< 5
NFDHA20 ppt< 20< 20
NMeFOSAA6 ppt< 6< 6
PFBA5 ppt< 5< 5
PFBS3 ppt< 3< 3
PFDA3 ppt< 3< 3
PFDoA3 ppt< 3< 3
PFEESA3 ppt< 3< 3
PFHpA3 ppt< 3< 3
PFHpS3 ppt< 3< 3
PFHxA3 ppt< 3< 3
PFHxS3 ppt< 3< 3
PFMBA3 ppt< 3< 3
PFMPA4 ppt< 4< 4
PFNA4 ppt< 4< 4
PFOA4 ppt< 4< 4
PFOS4 ppt< 4< 4
PFPeA3 ppt< 3< 3
PFPeS4 ppt< 4< 4
PFTA8 ppt< 8< 8
PFTrDA7 ppt< 7< 7
PFUnA2 ppt< 2< 2
lithium9 µg/L< 9< 9

OAKWOOD FILTER PLANT facility TP08 · sample point TP08 · groundwater

CompoundMRL2023-09-05
SE1
2024-03-01
SE2
PFBS3 ppt3.63.5
PFHxS3 ppt4.13.5
11Cl-PF3OUdS5 ppt< 5< 5
4:2 FTS3 ppt< 3< 3
6:2 FTS5 ppt< 5< 5
8:2 FTS5 ppt< 5< 5
9Cl-PF3ONS2 ppt< 2< 2
ADONA3 ppt< 3< 3
HFPO-DA5 ppt< 5< 5
NEtFOSAA5 ppt< 5< 5
NFDHA20 ppt< 20< 20
NMeFOSAA6 ppt< 6< 6
PFBA5 ppt< 5< 5
PFDA3 ppt< 3< 3
PFDoA3 ppt< 3< 3
PFEESA3 ppt< 3< 3
PFHpA3 ppt< 3< 3
PFHpS3 ppt< 3< 3
PFHxA3 ppt< 3< 3
PFMBA3 ppt< 3< 3
PFMPA4 ppt< 4< 4
PFNA4 ppt< 4< 4
PFOA4 ppt< 4< 4
PFOS4 ppt< 4< 4
PFPeA3 ppt< 3< 3
PFPeS4 ppt< 4< 4
PFTA8 ppt< 8< 8
PFTrDA7 ppt< 7< 7
PFUnA2 ppt< 2< 2
lithium9 µg/L< 9< 9

WELL 8 TAP facility TP04 · sample point TP04 · groundwater

CompoundMRL2023-09-05
SE1
2023-11-20
SE1
2024-03-01
SE2
PFBS3 ppt–< 36
11Cl-PF3OUdS5 ppt–< 5< 5
4:2 FTS3 ppt–< 3< 3
6:2 FTS5 ppt–< 5< 5
8:2 FTS5 ppt–< 5< 5
9Cl-PF3ONS2 ppt–< 2< 2
ADONA3 ppt–< 3< 3
HFPO-DA5 ppt–< 5< 5
NEtFOSAA5 ppt< 5–< 5
NFDHA20 ppt–< 20< 20
NMeFOSAA6 ppt< 6–< 6
PFBA5 ppt–< 5< 5
PFDA3 ppt–< 3< 3
PFDoA3 ppt–< 3< 3
PFEESA3 ppt–< 3< 3
PFHpA3 ppt–< 3< 3
PFHpS3 ppt–< 3< 3
PFHxA3 ppt–< 3< 3
PFHxS3 ppt–< 3< 3
PFMBA3 ppt–< 3< 3
PFMPA4 ppt–< 4< 4
PFNA4 ppt–< 4< 4
PFOA4 ppt–< 4< 4
PFOS4 ppt–< 4< 4
PFPeA3 ppt–< 3< 3
PFPeS4 ppt–< 4< 4
PFTA8 ppt< 8–< 8
PFTrDA7 ppt< 7–< 7
PFUnA2 ppt–< 2< 2
lithium9 µg/L< 9–< 9

Statistics by compound

CompoundResultsDetectedHighest (date)Mean boundsKM medianP75P90P95
PFBS1242%7.3
2023-11-20
2.12–3.87<MRL3.667.3
PFHxS1225%4.1
2023-09-05
0.97–3.23<MRL<MRL4.14.1
PFOS128%4.2
2023-11-20
0.35–4.02<MRL<MRL<MRL4.2
PFPeA128%3
2023-11-20
0.25–3<MRL<MRL<MRL3

Never detected (26): 11Cl-PF3OUdS, 4:2 FTS, 6:2 FTS, 8:2 FTS, 9Cl-PF3ONS, ADONA, HFPO-DA, NEtFOSAA, NFDHA, NMeFOSAA, PFBA, PFDA, PFDoA, PFEESA, PFHpA, PFHpS, PFHxA, PFMBA, PFMPA, PFNA, PFOA, PFPeS, PFTA, PFTrDA, PFUnA, lithium.

Left-censored Kaplan–Meier statistics (Helsel 2005; Helsel & Lee 2006, NADA for R). Units: ppt; lithium µg/L. Each compound has one reporting limit, so the Kaplan–Meier mean equals the upper mean bound (non-detects at the MRL); the lower bound sets non-detects to 0. “<MRL” = the percentile falls below the reporting limit and cannot be estimated. These describe this system's UCMR 5 samples, not population estimates.

Sources

  • EPA UCMR 5 occurrence data text files (UCMR5_All.txt; samples 2023-01-09 to 2026-04-22; data summary dated Jul 2026)
  • EPA SDWIS via ECHO SDWA downloads, quarter 2026Q3
  • EPA Public Water System Service Areas v3 (Mar 2026)
  • US Census Bureau cartographic boundary counties 1:500k, 2024
  • EPA/USGS NHDPlus V2 (medium resolution) flowlines, Strahler order 2+

Data build 85f0496a668b · 2026-10-18T04:10Z · UCMR 5 release Jul2026 · SDWIS 2026Q3. Data and methods.