Bealeton Regional

PFAS monitoring results for a public water system in Virginia

VA6061129UCMR 5EPA monitoring data
44.6Highest PFOA result, ppt
31.1Highest PFOS result, ppt
1.259Highest Hazard Index
360Results
PWSID
VA6061129
State
Virginia
System type
community water system (CWS)
Population served
4,250
City
Warrenton
Counties
Fauquier County
Primary source water
groundwater under the influence of surface water
UCMR 5 sampling
2025-03-18 to 2025-12-17 · 3 entry point(s) · water types: GU
Service-area boundary
EPA-modeled (Random Forest) — approximate: estimated by EPA with a statistical model, not a surveyed service area

PFOA ≥ 3 × its limit highest single result
PFOA ≥ 3 × its limit worst entry-point average

These are monitoring results collected under EPA's Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) at entry points, where treated water enters the distribution system; they are not tap-water samples. They are not compliance determinations: compliance with EPA's 2024 PFAS limits is judged on running annual averages of compliance monitoring, required from 2029, so a single UCMR 5 result at or above a limit is not a violation. “< MRL” means the compound was not quantified at EPA's minimum reporting level; it does not mean zero.

Compared with EPA's 2024 values

Highest single resultWorst entry-point average*Limit
PFOA (ppt)44.623.124
PFOS (ppt)31.114.654
Hazard Index1.2590.4951.0†

“<MRL” = every result for the compound was below its reporting limit. * Mean of all samples at each entry point with non-detects = 0 (EPA compliance convention; the Hazard Index also uses non-detects = 0); a screening comparison, not a formal running annual average. † Rescission proposed May 2026. PFOA/PFOS MCL 4 ppt (2024 NPDWR, in effect). PFHxS, PFNA, HFPO-DA (10 ppt each) and the Hazard Index (1.0) are 2024 NPDWR values; EPA proposed rescinding them on 18 May 2026 (comment period closed 20 Jul 2026).

No Virginia PFAS drinking-water standard in effect or proposed as of 2026-10-17: No Virginia-specific PFAS drinking-water MCL; Va. Code 62.1-44.34:29 defines PFAS MCL by reference to EPA's NPDWR.

Sampling history

Sampled 2025-03-18 to 2025-12-17 · 3 entry point(s) · water types: GU · 12 sampling visits. PFAS in ppt (ng/L).

DateEntry pointEventPFOAPFOSHIOther detections
2025-03-18BEALETON REGIONAL (GU)SE1<4<40PFBA 6.6, PFHxA 4.4, PFPeA 7.7, lithium 67.1 µg/L
2025-03-18BEALETON REGIONAL (GU)SE120.313.70.386PFBA 6.7, PFHpA 6.6, PFHxA 7.2, PFPeA 7.5, lithium 41.4 µg/L
2025-03-18BEALETON REGIONAL (GU)SE119.911.70.376PFBA 6.6, PFHpA 6.6, PFHxA 7.5, PFPeA 7.7, lithium 39.4 µg/L
2025-06-16BEALETON REGIONAL (GU)SE2<4<40PFBA 7.3, PFHxA 3.8, PFPeA 7.1, lithium 86 µg/L
2025-06-16BEALETON REGIONAL (GU)SE244.331.11.259PFBA 9.7, PFHpA 14.9, PFHxA 17.8, PFPeA 16.5, lithium 27.1 µg/L
2025-06-16BEALETON REGIONAL (GU)SE244.628.51.219PFBA 9.4, PFHpA 15.4, PFHxA 17.6, PFPeA 16.9, lithium 27.8 µg/L
2025-09-24BEALETON REGIONAL (GU)SE3<4<40.002PFBA 7.3, PFHxA 4.3, PFPeA 7.5, lithium 80.4 µg/L
2025-09-24BEALETON REGIONAL (GU)SE317.38.50.334PFBA 6.9, PFHpA 5.6, PFHxA 7, PFPeA 7.7, lithium 52.7 µg/L
2025-09-24BEALETON REGIONAL (GU)SE3168.40.304PFBA 6.5, PFHpA 5.4, PFHxA 6.6, PFPeA 7.5, lithium 52.3 µg/L
2025-12-15BEALETON REGIONAL (GU)SE4<4<40PFDA 3, PFHxA 3.4, PFPeA 6.2, lithium 48.3 µg/L
2025-12-17BEALETON REGIONAL (GU)SE49.45.30.003PFHpA 3.2, PFHxA 3.7, PFPeA 4.2, lithium 45.8 µg/L
2025-12-17BEALETON REGIONAL (GU)SE4125.50.003PFBA 5, PFHpA 4.4, PFHxA 5.1, PFPeA 5.5, lithium 49.4 µg/L

“<4” = not detected at the reporting limit shown; “n/a” = not analyzed in that sample. Highlighted = at or above the 4 ppt MCL. HI computed per sample with non-detects as 0. Other detections lists every other quantified compound (lithium in µg/L).

All results by entry point

360 results. Each column is one sampling visit (date and UCMR 5 sample event). A number is a measured concentration; “< 4” = below the minimum reporting level shown; “–” = not analyzed in that visit. PFAS in ppt (ng/L); lithium in µg/L.

BEALETON REGIONAL facility EP003 · sample point EP003 · groundwater under the influence of surface water

CompoundMRL2025-03-18
SE1
2025-06-16
SE2
2025-09-24
SE3
2025-12-15
SE4
PFBA5 ppt6.67.37.3< 5
PFBS3 ppt< 3< 33.1< 3
PFDA3 ppt< 3< 3< 33
PFHxA3 ppt4.43.84.33.4
PFPeA3 ppt7.77.17.56.2
11Cl-PF3OUdS5 ppt< 5< 5< 5< 5
4:2 FTS3 ppt< 3< 3< 3< 3
6:2 FTS5 ppt< 5< 5< 5< 5
8:2 FTS5 ppt< 5< 5< 5< 5
9Cl-PF3ONS2 ppt< 2< 2< 2< 2
ADONA3 ppt< 3< 3< 3< 3
HFPO-DA5 ppt< 5< 5< 5< 5
NEtFOSAA5 ppt< 5< 5< 5< 5
NFDHA20 ppt< 20< 20< 20< 20
NMeFOSAA6 ppt< 6< 6< 6< 6
PFDoA3 ppt< 3< 3< 3< 3
PFEESA3 ppt< 3< 3< 3< 3
PFHpA3 ppt< 3< 3< 3< 3
PFHpS3 ppt< 3< 3< 3< 3
PFHxS3 ppt< 3< 3< 3< 3
PFMBA3 ppt< 3< 3< 3< 3
PFMPA4 ppt< 4< 4< 4< 4
PFNA4 ppt< 4< 4< 4< 4
PFOA4 ppt< 4< 4< 4< 4
PFOS4 ppt< 4< 4< 4< 4
PFPeS4 ppt< 4< 4< 4< 4
PFTA8 ppt< 8< 8< 8< 8
PFTrDA7 ppt< 7< 7< 7< 7
PFUnA2 ppt< 2< 2< 2< 2
lithium9 µg/L67.18680.448.3

BEALETON REGIONAL facility EP007 · sample point EP007 · groundwater under the influence of surface water

CompoundMRL2025-03-18
SE1
2025-06-16
SE2
2025-09-24
SE3
2025-12-17
SE4
PFBA5 ppt6.79.76.9< 5
PFBS3 ppt11.418.88.95.2
PFHpA3 ppt6.614.95.63.2
PFHxA3 ppt7.217.873.7
PFHxS3 ppt3.87.53.3< 3
PFNA4 ppt< 45< 4< 4
PFOA4 ppt20.344.317.39.4
PFOS4 ppt13.731.18.55.3
PFPeA3 ppt7.516.57.74.2
11Cl-PF3OUdS5 ppt< 5< 5< 5< 5
4:2 FTS3 ppt< 3< 3< 3< 3
6:2 FTS5 ppt< 5< 5< 5< 5
8:2 FTS5 ppt< 5< 5< 5< 5
9Cl-PF3ONS2 ppt< 2< 2< 2< 2
ADONA3 ppt< 3< 3< 3< 3
HFPO-DA5 ppt< 5< 5< 5< 5
NEtFOSAA5 ppt< 5< 5< 5< 5
NFDHA20 ppt< 20< 20< 20< 20
NMeFOSAA6 ppt< 6< 6< 6< 6
PFDA3 ppt< 3< 3< 3< 3
PFDoA3 ppt< 3< 3< 3< 3
PFEESA3 ppt< 3< 3< 3< 3
PFHpS3 ppt< 3< 3< 3< 3
PFMBA3 ppt< 3< 3< 3< 3
PFMPA4 ppt< 4< 4< 4< 4
PFPeS4 ppt< 4< 4< 4< 4
PFTA8 ppt< 8< 8< 8< 8
PFTrDA7 ppt< 7< 7< 7< 7
PFUnA2 ppt< 2< 2< 2< 2
lithium9 µg/L41.427.152.745.8

BEALETON REGIONAL facility EP008 · sample point EP008 · groundwater under the influence of surface water

CompoundMRL2025-03-18
SE1
2025-06-16
SE2
2025-09-24
SE3
2025-12-17
SE4
PFBA5 ppt6.69.46.55
PFBS3 ppt11.518.58.56.5
PFHpA3 ppt6.615.45.44.4
PFHxA3 ppt7.517.66.65.1
PFHxS3 ppt3.77.53< 3
PFNA4 ppt< 44.6< 4< 4
PFOA4 ppt19.944.61612
PFOS4 ppt11.728.58.45.5
PFPeA3 ppt7.716.97.55.5
11Cl-PF3OUdS5 ppt< 5< 5< 5< 5
4:2 FTS3 ppt< 3< 3< 3< 3
6:2 FTS5 ppt< 5< 5< 5< 5
8:2 FTS5 ppt< 5< 5< 5< 5
9Cl-PF3ONS2 ppt< 2< 2< 2< 2
ADONA3 ppt< 3< 3< 3< 3
HFPO-DA5 ppt< 5< 5< 5< 5
NEtFOSAA5 ppt< 5< 5< 5< 5
NFDHA20 ppt< 20< 20< 20< 20
NMeFOSAA6 ppt< 6< 6< 6< 6
PFDA3 ppt< 3< 3< 3< 3
PFDoA3 ppt< 3< 3< 3< 3
PFEESA3 ppt< 3< 3< 3< 3
PFHpS3 ppt< 3< 3< 3< 3
PFMBA3 ppt< 3< 3< 3< 3
PFMPA4 ppt< 4< 4< 4< 4
PFPeS4 ppt< 4< 4< 4< 4
PFTA8 ppt< 8< 8< 8< 8
PFTrDA7 ppt< 7< 7< 7< 7
PFUnA2 ppt< 2< 2< 2< 2
lithium9 µg/L39.427.852.349.4

Statistics by compound

CompoundResultsDetectedHighest (date)Mean boundsKM medianP75P90P95
PFHxA12100%17.8
2025-06-16
7.37–7.375.17.217.617.8
PFPeA12100%16.9
2025-06-16
8.5–8.57.57.716.516.9
lithium12100%86
2025-06-16
51.48–51.4848.352.780.486
PFBA1283%9.7
2025-06-16
6–6.836.67.39.49.7
PFBS1275%18.8
2025-06-16
7.7–8.456.511.418.518.8
PFHpA1267%15.4
2025-06-16
5.17–6.174.46.614.915.4
PFOA1267%44.6
2025-06-16
15.32–16.651219.944.344.6
PFOS1267%31.1
2025-06-16
9.39–10.725.511.728.531.1
PFHxS1250%7.5
2025-06-16
2.4–3.9<MRL3.77.57.5
PFNA1217%5
2025-06-16
0.8–4.13<MRL<MRL4.65
PFDA128%3
2025-12-15
0.25–3<MRL<MRL<MRL3

Never detected (19): 11Cl-PF3OUdS, 4:2 FTS, 6:2 FTS, 8:2 FTS, 9Cl-PF3ONS, ADONA, HFPO-DA, NEtFOSAA, NFDHA, NMeFOSAA, PFDoA, PFEESA, PFHpS, PFMBA, PFMPA, PFPeS, PFTA, PFTrDA, PFUnA.

Left-censored Kaplan–Meier statistics (Helsel 2005; Helsel & Lee 2006, NADA for R). Units: ppt; lithium µg/L. Each compound has one reporting limit, so the Kaplan–Meier mean equals the upper mean bound (non-detects at the MRL); the lower bound sets non-detects to 0. “<MRL” = the percentile falls below the reporting limit and cannot be estimated. These describe this system's UCMR 5 samples, not population estimates.

Sources

  • EPA UCMR 5 occurrence data text files (UCMR5_All.txt; samples 2023-01-10 to 2026-03-04; data summary dated Jul 2026)
  • EPA SDWIS via ECHO SDWA downloads, quarter 2026Q3
  • EPA Public Water System Service Areas v3 (Mar 2026)
  • US Census Bureau cartographic boundary counties 1:500k, 2024
  • EPA/USGS NHDPlus V2 (medium resolution) flowlines, Strahler order 2+

Data build c525414e2fcb · 2026-10-18T04:06Z · UCMR 5 release Jul2026 · SDWIS 2026Q3. Data and methods.