City Of Pflugerville

PFAS monitoring results for a public water system in Texas

TX2270014UCMR 5EPA monitoring data
6.3Highest PFOA result, ppt
14.4Highest PFOS result, ppt
3.195Highest Hazard Index
240Results
PWSID
TX2270014
State
Texas
System type
community water system (CWS)
Population served
63,464
City
Pflugerville
Counties
Travis County
Primary source water
surface water
UCMR 5 sampling
2025-03-17 to 2025-12-01 · 3 entry point(s) · water types: GW;SW
Service-area boundary
authoritative

PFOS ≥ 3 × its limit highest single result
PFOS ≥ 3 × its limit worst entry-point average

These are monitoring results collected under EPA's Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) at entry points, where treated water enters the distribution system; they are not tap-water samples. They are not compliance determinations: compliance with EPA's 2024 PFAS limits is judged on running annual averages of compliance monitoring, required from 2029, so a single UCMR 5 result at or above a limit is not a violation. “< MRL” means the compound was not quantified at EPA's minimum reporting level; it does not mean zero.

Water purchased from

  • Manville Wsc (TX2270033)
    Seller's highest results: PFOA 5.9 ppt · PFOS 12.4 ppt · HI 3.135 · detected: PFBA;PFBS;PFHpA;PFHxA;PFHxS;PFNA;PFOA;PFOS;PFPeA;PFUnA

Seller results are the seller's own entry-point samples, not measurements of this system's water. This system's own samples (below) may reflect purchased water, its own sources, or both.

Compared with EPA's 2024 values

Highest single resultWorst entry-point average*Limit
PFOA (ppt)6.36.34
PFOS (ppt)14.413.954
Hazard Index3.1953.1451.0†

“<MRL” = every result for the compound was below its reporting limit. * Mean of all samples at each entry point with non-detects = 0 (EPA compliance convention; the Hazard Index also uses non-detects = 0); a screening comparison, not a formal running annual average. † Rescission proposed May 2026. PFOA/PFOS MCL 4 ppt (2024 NPDWR, in effect). PFHxS, PFNA, HFPO-DA (10 ppt each) and the Hazard Index (1.0) are 2024 NPDWR values; EPA proposed rescinding them on 18 May 2026 (comment period closed 20 Jul 2026).

No Texas PFAS drinking-water standard in effect or proposed as of 2026-10-17: No state PFAS drinking-water standard; TCEQ implementing federal NPDWR (BCLP state survey, Jan 2026).

Sampling history

Sampled 2025-03-17 to 2025-12-01 · 3 entry point(s) · water types: GW;SW · 10 sampling visits. PFAS in ppt (ng/L).

DateEntry pointEventPFOAPFOSHIOther detections
2025-03-17Surface Water Treatment Plant (SW)SE1<45.50.382PFHxA 3.2, PFPeA 3.3
2025-03-17Well 6 (GW)SE16.312.63.145PFBA 7.9, PFHpA 4.8, PFHxA 8.4, PFPeA 11.8, PFUnA 2.3
2025-05-12Surface Water Treatment Plant (SW)SE1n/an/an/anone
2025-05-12Well 7 (GW)SE16.113.53.095PFBA 8.1, PFHpA 4.5, PFHxA 8.3, PFPeA 11.5, PFUnA 2.7, lithium 11 µg/L
2025-06-26Surface Water Treatment Plant (SW)SE2n/an/an/alithium 9.1 µg/L
2025-08-18Surface Water Treatment Plant (SW)SE2<4<40.302PFBA 7.1, PFHxA 3.2, PFPeA 3.3
2025-09-23Well 6 (GW)SE26.3143.115PFBA 8, PFHpA 4.7, PFHxA 9.3, PFPeA 13.3, PFUnA 2.6
2025-09-23Well 7 (GW)SE26.114.43.195PFBA 8, PFHpA 4.9, PFHxA 9.1, PFPeA 12.2, PFUnA 2.7, lithium 13.9 µg/L
2025-09-24Surface Water Treatment Plant (SW)SE3<4<40.37PFBA 6.1, PFHxA 3, PFPeA 3.9
2025-12-01Surface Water Treatment Plant (SW)SE4<4<40.3PFBA 5.9, lithium 10.3 µg/L

“<4” = not detected at the reporting limit shown; “n/a” = not analyzed in that sample. Highlighted = at or above the 4 ppt MCL. HI computed per sample with non-detects as 0. Other detections lists every other quantified compound (lithium in µg/L).

All results by entry point

240 results. Each column is one sampling visit (date and UCMR 5 sample event). A number is a measured concentration; “< 4” = below the minimum reporting level shown; “–” = not analyzed in that visit. PFAS in ppt (ng/L); lithium in µg/L.

Surface Water Treatment Plant facility EP007 · sample point EP007 · surface water

CompoundMRL2025-03-17
SE1
2025-05-12
SE1
2025-06-26
SE2
2025-08-18
SE2
2025-09-24
SE3
2025-12-01
SE4
PFBA5 ppt< 5––7.16.15.9
PFBS3 ppt3.7––3.4< 3< 3
PFHxA3 ppt3.2––3.23< 3
PFHxS3 ppt3.8––33.73
PFOS4 ppt5.5––< 4< 4< 4
PFPeA3 ppt3.3––3.33.9< 3
11Cl-PF3OUdS5 ppt< 5––< 5< 5< 5
4:2 FTS3 ppt< 3––< 3< 3< 3
6:2 FTS5 ppt< 5––< 5< 5< 5
8:2 FTS5 ppt< 5––< 5< 5< 5
9Cl-PF3ONS2 ppt< 2––< 2< 2< 2
ADONA3 ppt< 3––< 3< 3< 3
HFPO-DA5 ppt< 5––< 5< 5< 5
NEtFOSAA5 ppt–< 5< 5–< 5< 5
NFDHA20 ppt< 20––< 20< 20< 20
NMeFOSAA6 ppt–< 6< 6–< 6< 6
PFDA3 ppt< 3––< 3< 3< 3
PFDoA3 ppt< 3––< 3< 3< 3
PFEESA3 ppt< 3––< 3< 3< 3
PFHpA3 ppt< 3––< 3< 3< 3
PFHpS3 ppt< 3––< 3< 3< 3
PFMBA3 ppt< 3––< 3< 3< 3
PFMPA4 ppt< 4––< 4< 4< 4
PFNA4 ppt< 4––< 4< 4< 4
PFOA4 ppt< 4––< 4< 4< 4
PFPeS4 ppt< 4––< 4< 4< 4
PFTA8 ppt–< 8< 8–< 8< 8
PFTrDA7 ppt–< 7< 7–< 7< 7
PFUnA2 ppt< 2––< 2< 2< 2
lithium9 µg/L< 9–9.1–< 910.3

Well 6 facility EP004 · sample point EP004 · groundwater

CompoundMRL2025-03-17
SE1
2025-09-23
SE2
PFBA5 ppt7.98
PFBS3 ppt9.79.6
PFHpA3 ppt4.84.7
PFHxA3 ppt8.49.3
PFHxS3 ppt6.26.7
PFNA4 ppt25.224.4
PFOA4 ppt6.36.3
PFOS4 ppt12.614
PFPeA3 ppt11.813.3
PFUnA2 ppt2.32.6
11Cl-PF3OUdS5 ppt< 5< 5
4:2 FTS3 ppt< 3< 3
6:2 FTS5 ppt< 5< 5
8:2 FTS5 ppt< 5< 5
9Cl-PF3ONS2 ppt< 2< 2
ADONA3 ppt< 3< 3
HFPO-DA5 ppt< 5< 5
NEtFOSAA5 ppt< 5< 5
NFDHA20 ppt< 20< 20
NMeFOSAA6 ppt< 6< 6
PFDA3 ppt< 3< 3
PFDoA3 ppt< 3< 3
PFEESA3 ppt< 3< 3
PFHpS3 ppt< 3< 3
PFMBA3 ppt< 3< 3
PFMPA4 ppt< 4< 4
PFPeS4 ppt< 4< 4
PFTA8 ppt< 8< 8
PFTrDA7 ppt< 7< 7
lithium9 µg/L< 9< 9

Well 7 facility EP003 · sample point EP003 · groundwater

CompoundMRL2025-05-12
SE1
2025-09-23
SE2
PFBA5 ppt8.18
PFBS3 ppt9.59.4
PFHpA3 ppt4.54.9
PFHxA3 ppt8.39.1
PFHxS3 ppt6.57.2
PFNA4 ppt24.424.7
PFOA4 ppt6.16.1
PFOS4 ppt13.514.4
PFPeA3 ppt11.512.2
PFUnA2 ppt2.72.7
11Cl-PF3OUdS5 ppt< 5< 5
4:2 FTS3 ppt< 3< 3
6:2 FTS5 ppt< 5< 5
8:2 FTS5 ppt< 5< 5
9Cl-PF3ONS2 ppt< 2< 2
ADONA3 ppt< 3< 3
HFPO-DA5 ppt< 5< 5
NEtFOSAA5 ppt< 5< 5
NFDHA20 ppt< 20< 20
NMeFOSAA6 ppt< 6< 6
PFDA3 ppt< 3< 3
PFDoA3 ppt< 3< 3
PFEESA3 ppt< 3< 3
PFHpS3 ppt< 3< 3
PFMBA3 ppt< 3< 3
PFMPA4 ppt< 4< 4
PFPeS4 ppt< 4< 4
PFTA8 ppt< 8< 8
PFTrDA7 ppt< 7< 7
lithium9 µg/L1113.9

Statistics by compound

CompoundResultsDetectedHighest (date)Mean boundsKM medianP75P90P95
PFHxS8100%7.2
2025-09-23
5.01–5.013.86.57.27.2
PFBA888%8.1
2025-05-12
6.39–7.017.188.18.1
PFHxA888%9.3
2025-09-23
5.56–5.943.28.49.39.3
PFPeA888%13.3
2025-09-23
7.41–7.793.911.813.313.3
PFBS875%9.7
2025-03-17
5.66–6.413.79.59.79.7
PFOS862%14.4
2025-09-23
7.5–95.513.514.414.4
PFHpA850%4.9
2025-09-23
2.36–3.86<MRL4.74.94.9
PFNA850%25.2
2025-03-17
12.34–14.34<MRL24.425.225.2
PFOA850%6.3
2025-03-17
3.1–5.1<MRL6.16.36.3
PFUnA850%2.7
2025-05-12
1.29–2.29<MRL2.62.72.7
lithium850%13.9
2025-09-23
5.54–10.04<MRL10.313.913.9

Never detected (19): 11Cl-PF3OUdS, 4:2 FTS, 6:2 FTS, 8:2 FTS, 9Cl-PF3ONS, ADONA, HFPO-DA, NEtFOSAA, NFDHA, NMeFOSAA, PFDA, PFDoA, PFEESA, PFHpS, PFMBA, PFMPA, PFPeS, PFTA, PFTrDA.

Left-censored Kaplan–Meier statistics (Helsel 2005; Helsel & Lee 2006, NADA for R). Units: ppt; lithium µg/L. Each compound has one reporting limit, so the Kaplan–Meier mean equals the upper mean bound (non-detects at the MRL); the lower bound sets non-detects to 0. “<MRL” = the percentile falls below the reporting limit and cannot be estimated. These describe this system's UCMR 5 samples, not population estimates.

Sources

  • EPA UCMR 5 occurrence data text files (UCMR5_All.txt; samples 2023-01-09 to 2026-06-16; data summary dated Jul 2026)
  • EPA SDWIS via ECHO SDWA downloads, quarter 2026Q3
  • EPA Public Water System Service Areas v3 (Mar 2026)
  • US Census Bureau cartographic boundary counties 1:500k, 2024
  • EPA/USGS NHDPlus V2 (medium resolution) flowlines, Strahler order 2+

Data build a6f3d99247ed · 2026-10-18T04:13Z · UCMR 5 release Jul2026 · SDWIS 2026Q3. Data and methods.