City Of Baytown

PFAS monitoring results for a public water system in Texas

TX1010003UCMR 5EPA monitoring data
<MRLHighest PFOA result, ppt
6Highest PFOS result, ppt
0.513Highest Hazard Index
240Results
PWSID
TX1010003
State
Texas
System type
community water system (CWS)
Population served
86,004
City
Baytown
Counties
Chambers County, Harris County
Primary source water
surface water (purchased)
UCMR 5 sampling
2023-04-19 to 2024-01-23 · 2 entry point(s) · water types: SW
Service-area boundary
authoritative

PFOS 1–3 × its limit highest single result
PFOS 1–3 × its limit worst entry-point average

These are monitoring results collected under EPA's Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) at entry points, where treated water enters the distribution system; they are not tap-water samples. They are not compliance determinations: compliance with EPA's 2024 PFAS limits is judged on running annual averages of compliance monitoring, required from 2029, so a single UCMR 5 result at or above a limit is not a violation. “< MRL” means the compound was not quantified at EPA's minimum reporting level; it does not mean zero.

Water purchased from

Seller results are the seller's own entry-point samples, not measurements of this system's water. This system's own samples (below) may reflect purchased water, its own sources, or both.

Compared with EPA's 2024 values

Highest single resultWorst entry-point average*Limit
PFOA (ppt)<MRL04
PFOS (ppt)65.554
Hazard Index0.5130.4571.0†

“<MRL” = every result for the compound was below its reporting limit. * Mean of all samples at each entry point with non-detects = 0 (EPA compliance convention; the Hazard Index also uses non-detects = 0); a screening comparison, not a formal running annual average. † Rescission proposed May 2026. PFOA/PFOS MCL 4 ppt (2024 NPDWR, in effect). PFHxS, PFNA, HFPO-DA (10 ppt each) and the Hazard Index (1.0) are 2024 NPDWR values; EPA proposed rescinding them on 18 May 2026 (comment period closed 20 Jul 2026).

No Texas PFAS drinking-water standard in effect or proposed as of 2026-10-17: No state PFAS drinking-water standard; TCEQ implementing federal NPDWR (BCLP state survey, Jan 2026).

Sampling history

Sampled 2023-04-19 to 2024-01-23 · 2 entry point(s) · water types: SW · 10 sampling visits. PFAS in ppt (ng/L).

DateEntry pointEventPFOAPFOSHIOther detections
2023-04-19Baytown Area Water Authority (SW)SE1<460.513PFBA 7.5, PFHxA 8.6, PFPeA 8
2023-04-19City of Baytown (SW)SE1<45.90.502PFBA 7.4, PFHpA 3, PFHxA 8, PFPeA 7.9
2023-07-20Baytown Area Water Authority (SW)SE2<44.80.36PFBA 13, PFHxA 5.8, PFPeA 6.8
2023-07-20City of Baytown (SW)SE2<44.10.361PFBA 11.1, PFHxA 5.3, PFPeA 6.6
2023-08-30Baytown Area Water Authority (SW)SE1n/an/an/anone
2023-08-30City of Baytown (SW)SE1n/an/an/anone
2023-10-23Baytown Area Water Authority (SW)SE3<45.50.503PFBA 14.6, PFHpA 3.7, PFHxA 9.8, PFPeA 8.9, lithium 13.4 µg/L
2023-10-23City of Baytown (SW)SE3<4<40lithium 13.8 µg/L
2024-01-23Baytown Area Water Authority (SW)SE4<45.90.453PFBA 10.1, PFHpA 3.2, PFHxA 9.5, PFPeA 10.2
2024-01-23City of Baytown (SW)SE4<45.80.442PFBA 11.8, PFHpA 3.1, PFHxA 9.4, PFPeA 10.1

“<4” = not detected at the reporting limit shown; “n/a” = not analyzed in that sample. Highlighted = at or above the 4 ppt MCL. HI computed per sample with non-detects as 0. Other detections lists every other quantified compound (lithium in µg/L).

All results by entry point

240 results. Each column is one sampling visit (date and UCMR 5 sample event). A number is a measured concentration; “< 4” = below the minimum reporting level shown; “–” = not analyzed in that visit. PFAS in ppt (ng/L); lithium in µg/L.

Baytown Area Water Authority facility 14858 · sample point EP001 · surface water

CompoundMRL2023-04-19
SE1
2023-07-20
SE2
2023-08-30
SE1
2023-10-23
SE3
2024-01-23
SE4
PFBA5 ppt7.513–14.610.1
PFBS3 ppt5.5< 3–5.75.1
PFHpA3 ppt< 3< 3–3.73.2
PFHxA3 ppt8.65.8–9.89.5
PFHxS3 ppt5.13.6–54.5
PFOS4 ppt64.8–5.55.9
PFPeA3 ppt86.8–8.910.2
11Cl-PF3OUdS5 ppt< 5< 5–< 5< 5
4:2 FTS3 ppt< 3< 3–< 3< 3
6:2 FTS5 ppt< 5< 5–< 5< 5
8:2 FTS5 ppt< 5< 5–< 5< 5
9Cl-PF3ONS2 ppt< 2< 2–< 2< 2
ADONA3 ppt< 3< 3–< 3< 3
HFPO-DA5 ppt< 5< 5–< 5< 5
NEtFOSAA5 ppt–< 5< 5< 5< 5
NFDHA20 ppt< 20< 20–< 20< 20
NMeFOSAA6 ppt–< 6< 6< 6< 6
PFDA3 ppt< 3< 3–< 3< 3
PFDoA3 ppt< 3< 3–< 3< 3
PFEESA3 ppt< 3< 3–< 3< 3
PFHpS3 ppt< 3< 3–< 3< 3
PFMBA3 ppt< 3< 3–< 3< 3
PFMPA4 ppt< 4< 4–< 4< 4
PFNA4 ppt< 4< 4–< 4< 4
PFOA4 ppt< 4< 4–< 4< 4
PFPeS4 ppt< 4< 4–< 4< 4
PFTA8 ppt–< 8< 8< 8< 8
PFTrDA7 ppt–< 7< 7< 7< 7
PFUnA2 ppt< 2< 2–< 2< 2
lithium9 µg/L< 9< 9–13.4< 9

City of Baytown facility 35001 · sample point EP001 · surface water

CompoundMRL2023-04-19
SE1
2023-07-20
SE2
2023-08-30
SE1
2023-10-23
SE3
2024-01-23
SE4
PFBA5 ppt7.411.1–< 511.8
PFBS3 ppt3.73.1–< 34.7
PFHpA3 ppt3< 3–< 33.1
PFHxA3 ppt85.3–< 39.4
PFHxS3 ppt53.6–< 34.4
PFOS4 ppt5.94.1–< 45.8
PFPeA3 ppt7.96.6–< 310.1
11Cl-PF3OUdS5 ppt< 5< 5–< 5< 5
4:2 FTS3 ppt< 3< 3–< 3< 3
6:2 FTS5 ppt< 5< 5–< 5< 5
8:2 FTS5 ppt< 5< 5–< 5< 5
9Cl-PF3ONS2 ppt< 2< 2–< 2< 2
ADONA3 ppt< 3< 3–< 3< 3
HFPO-DA5 ppt< 5< 5–< 5< 5
NEtFOSAA5 ppt–< 5< 5< 5< 5
NFDHA20 ppt< 20< 20–< 20< 20
NMeFOSAA6 ppt–< 6< 6< 6< 6
PFDA3 ppt< 3< 3–< 3< 3
PFDoA3 ppt< 3< 3–< 3< 3
PFEESA3 ppt< 3< 3–< 3< 3
PFHpS3 ppt< 3< 3–< 3< 3
PFMBA3 ppt< 3< 3–< 3< 3
PFMPA4 ppt< 4< 4–< 4< 4
PFNA4 ppt< 4< 4–< 4< 4
PFOA4 ppt< 4< 4–< 4< 4
PFPeS4 ppt< 4< 4–< 4< 4
PFTA8 ppt–< 8< 8< 8< 8
PFTrDA7 ppt–< 7< 7< 7< 7
PFUnA2 ppt< 2< 2–< 2< 2
lithium9 µg/L< 9< 9–13.8< 9

Statistics by compound

CompoundResultsDetectedHighest (date)Mean boundsKM medianP75P90P95
PFBA888%14.6
2023-10-23
9.44–10.0610.111.814.614.6
PFHxA888%9.8
2023-10-23
7.05–7.4289.49.89.8
PFHxS888%5.1
2023-04-19
3.9–4.284.455.15.1
PFOS888%6
2023-04-19
4.75–5.255.55.966
PFPeA888%10.2
2024-01-23
7.31–7.697.98.910.210.2
PFBS875%5.7
2023-10-23
3.48–4.223.75.15.75.7
PFHpA850%3.7
2023-10-23
1.62–3.12<MRL3.13.73.7
lithium825%13.8
2023-10-23
3.4–10.15<MRL<MRL13.813.8

Never detected (22): 11Cl-PF3OUdS, 4:2 FTS, 6:2 FTS, 8:2 FTS, 9Cl-PF3ONS, ADONA, HFPO-DA, NEtFOSAA, NFDHA, NMeFOSAA, PFDA, PFDoA, PFEESA, PFHpS, PFMBA, PFMPA, PFNA, PFOA, PFPeS, PFTA, PFTrDA, PFUnA.

Left-censored Kaplan–Meier statistics (Helsel 2005; Helsel & Lee 2006, NADA for R). Units: ppt; lithium µg/L. Each compound has one reporting limit, so the Kaplan–Meier mean equals the upper mean bound (non-detects at the MRL); the lower bound sets non-detects to 0. “<MRL” = the percentile falls below the reporting limit and cannot be estimated. These describe this system's UCMR 5 samples, not population estimates.

Sources

  • EPA UCMR 5 occurrence data text files (UCMR5_All.txt; samples 2023-01-09 to 2026-06-16; data summary dated Jul 2026)
  • EPA SDWIS via ECHO SDWA downloads, quarter 2026Q3
  • EPA Public Water System Service Areas v3 (Mar 2026)
  • US Census Bureau cartographic boundary counties 1:500k, 2024
  • EPA/USGS NHDPlus V2 (medium resolution) flowlines, Strahler order 2+

Data build a6f3d99247ed · 2026-10-18T04:13Z · UCMR 5 release Jul2026 · SDWIS 2026Q3. Data and methods.