Savannah Valley U.D.

PFAS monitoring results for a public water system in Tennessee

TN0000613UCMR 5EPA monitoring data
35Highest PFOA result, ppt
18Highest PFOS result, ppt
0.494Highest Hazard Index
300Results
PWSID
TN0000613
State
Tennessee
System type
community water system (CWS)
Population served
30,571
City
Georgetown
Counties
Bradley County, Hamilton County, Meigs County
Primary source water
groundwater under the influence of surface water
UCMR 5 sampling
2024-03-18 to 2024-12-03 · 3 entry point(s) · water types: GU;GW;SW
Service-area boundary
authoritative

PFOA ≥ 3 × its limit highest single result
PFOA ≥ 3 × its limit worst entry-point average

These are monitoring results collected under EPA's Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) at entry points, where treated water enters the distribution system; they are not tap-water samples. They are not compliance determinations: compliance with EPA's 2024 PFAS limits is judged on running annual averages of compliance monitoring, required from 2029, so a single UCMR 5 result at or above a limit is not a violation. “< MRL” means the compound was not quantified at EPA's minimum reporting level; it does not mean zero.

Water purchased from

  • Cleveland Utilities (TN0000117)
    Seller's highest results: PFOA <MRL · PFOS <MRL · HI 0.016 · detected: PFBA;PFBS;PFPeA

Seller results are the seller's own entry-point samples, not measurements of this system's water. This system's own samples (below) may reflect purchased water, its own sources, or both.

Compared with EPA's 2024 values

Highest single resultWorst entry-point average*Limit
PFOA (ppt)35324
PFOS (ppt)1816.54
Hazard Index0.4940.4671.0†

“<MRL” = every result for the compound was below its reporting limit. * Mean of all samples at each entry point with non-detects = 0 (EPA compliance convention; the Hazard Index also uses non-detects = 0); a screening comparison, not a formal running annual average. † Rescission proposed May 2026. PFOA/PFOS MCL 4 ppt (2024 NPDWR, in effect). PFHxS, PFNA, HFPO-DA (10 ppt each) and the Hazard Index (1.0) are 2024 NPDWR values; EPA proposed rescinding them on 18 May 2026 (comment period closed 20 Jul 2026).

No Tennessee PFAS drinking-water standard in effect or proposed as of 2026-10-17: No state PFAS drinking-water standard; follows federal NPDWR (BCLP state survey, Jan 2026).

Sampling history

Sampled 2024-03-18 to 2024-12-03 · 3 entry point(s) · water types: GU;GW;SW · 11 sampling visits. PFAS in ppt (ng/L).

DateEntry pointEventPFOAPFOSHIOther detections
2024-03-18Carson Spring Well Water Plant (GW)SE135180.494PFBA 13, PFHpA 14, PFHxA 28, PFPeA 30
2024-03-18Eastside UD Connection (SW)SE1<4<40PFBA 9.7
2024-03-18Smith Rd. Plant (GU)SE1<4<40.004none
2024-06-11Smith Rd. Plant (GU)SE2n/an/an/anone
2024-06-12Eastside UD Connection (SW)SE2<4<40PFBA 8.4
2024-06-28Smith Rd. Plant (GU)SE2<4<40.003none
2024-09-09Carson Spring Well Water Plant (GW)SE229150.44PFBA 12, PFHpA 11, PFHxA 24, PFPeA 25
2024-09-09Eastside UD Connection (SW)SE3<4<40none
2024-09-09Smith Rd. Plant (GU)SE3<4<40.005none
2024-12-03Eastside UD Connection (SW)SE4<4<40none
2024-12-03Smith Rd. Plant (GU)SE4<4<40.005none

“<4” = not detected at the reporting limit shown; “n/a” = not analyzed in that sample. Highlighted = at or above the 4 ppt MCL. HI computed per sample with non-detects as 0. Other detections lists every other quantified compound (lithium in µg/L).

All results by entry point

300 results. Each column is one sampling visit (date and UCMR 5 sample event). A number is a measured concentration; “< 4” = below the minimum reporting level shown; “–” = not analyzed in that visit. PFAS in ppt (ng/L); lithium in µg/L.

Carson Spring Well Water Plant facility 90003 · sample point TP003 · groundwater

CompoundMRL2024-03-18
SE1
2024-09-09
SE2
PFBA5 ppt1312
PFBS3 ppt4940
PFHpA3 ppt1411
PFHxA3 ppt2824
PFHxS3 ppt4.74.2
PFOA4 ppt3529
PFOS4 ppt1815
PFPeA3 ppt3025
11Cl-PF3OUdS5 ppt< 5< 5
4:2 FTS3 ppt< 3< 3
6:2 FTS5 ppt< 5< 5
8:2 FTS5 ppt< 5< 5
9Cl-PF3ONS2 ppt< 2< 2
ADONA3 ppt< 3< 3
HFPO-DA5 ppt< 5< 5
NEtFOSAA5 ppt< 5< 5
NFDHA20 ppt< 20< 20
NMeFOSAA6 ppt< 6< 6
PFDA3 ppt< 3< 3
PFDoA3 ppt< 3< 3
PFEESA3 ppt< 3< 3
PFHpS3 ppt< 3< 3
PFMBA3 ppt< 3< 3
PFMPA4 ppt< 4< 4
PFNA4 ppt< 4< 4
PFPeS4 ppt< 4< 4
PFTA8 ppt< 8< 8
PFTrDA7 ppt< 7< 7
PFUnA2 ppt< 2< 2
lithium9 µg/L< 9< 9

Eastside UD Connection facility 95002 · sample point CC04 · surface water

CompoundMRL2024-03-18
SE1
2024-06-12
SE2
2024-09-09
SE3
2024-12-03
SE4
PFBA5 ppt9.78.4< 5< 5
11Cl-PF3OUdS5 ppt< 5< 5< 5< 5
4:2 FTS3 ppt< 3< 3< 3< 3
6:2 FTS5 ppt< 5< 5< 5< 5
8:2 FTS5 ppt< 5< 5< 5< 5
9Cl-PF3ONS2 ppt< 2< 2< 2< 2
ADONA3 ppt< 3< 3< 3< 3
HFPO-DA5 ppt< 5< 5< 5< 5
NEtFOSAA5 ppt< 5< 5< 5< 5
NFDHA20 ppt< 20< 20< 20< 20
NMeFOSAA6 ppt< 6< 6< 6< 6
PFBS3 ppt< 3< 3< 3< 3
PFDA3 ppt< 3< 3< 3< 3
PFDoA3 ppt< 3< 3< 3< 3
PFEESA3 ppt< 3< 3< 3< 3
PFHpA3 ppt< 3< 3< 3< 3
PFHpS3 ppt< 3< 3< 3< 3
PFHxA3 ppt< 3< 3< 3< 3
PFHxS3 ppt< 3< 3< 3< 3
PFMBA3 ppt< 3< 3< 3< 3
PFMPA4 ppt< 4< 4< 4< 4
PFNA4 ppt< 4< 4< 4< 4
PFOA4 ppt< 4< 4< 4< 4
PFOS4 ppt< 4< 4< 4< 4
PFPeA3 ppt< 3< 3< 3< 3
PFPeS4 ppt< 4< 4< 4< 4
PFTA8 ppt< 8< 8< 8< 8
PFTrDA7 ppt< 7< 7< 7< 7
PFUnA2 ppt< 2< 2< 2< 2
lithium9 µg/L< 9< 9< 9< 9

Smith Rd. Plant facility 95001 · sample point TP001 · groundwater under the influence of surface water

CompoundMRL2024-03-18
SE1
2024-06-11
SE2
2024-06-28
SE2
2024-09-09
SE3
2024-12-03
SE4
PFBS3 ppt7.2–6.79.211
11Cl-PF3OUdS5 ppt< 5–< 5< 5< 5
4:2 FTS3 ppt< 3–< 3< 3< 3
6:2 FTS5 ppt< 5–< 5< 5< 5
8:2 FTS5 ppt< 5–< 5< 5< 5
9Cl-PF3ONS2 ppt< 2–< 2< 2< 2
ADONA3 ppt< 3–< 3< 3< 3
HFPO-DA5 ppt< 5–< 5< 5< 5
NEtFOSAA5 ppt< 5< 5–< 5< 5
NFDHA20 ppt< 20–< 20< 20< 20
NMeFOSAA6 ppt< 6< 6–< 6< 6
PFBA5 ppt< 5–< 5< 5< 5
PFDA3 ppt< 3–< 3< 3< 3
PFDoA3 ppt< 3–< 3< 3< 3
PFEESA3 ppt< 3–< 3< 3< 3
PFHpA3 ppt< 3–< 3< 3< 3
PFHpS3 ppt< 3–< 3< 3< 3
PFHxA3 ppt< 3–< 3< 3< 3
PFHxS3 ppt< 3–< 3< 3< 3
PFMBA3 ppt< 3–< 3< 3< 3
PFMPA4 ppt< 4–< 4< 4< 4
PFNA4 ppt< 4–< 4< 4< 4
PFOA4 ppt< 4–< 4< 4< 4
PFOS4 ppt< 4–< 4< 4< 4
PFPeA3 ppt< 3–< 3< 3< 3
PFPeS4 ppt< 4–< 4< 4< 4
PFTA8 ppt< 8< 8–< 8< 8
PFTrDA7 ppt< 7< 7–< 7< 7
PFUnA2 ppt< 2–< 2< 2< 2
lithium9 µg/L< 9< 9–< 9< 9

Statistics by compound

CompoundResultsDetectedHighest (date)Mean boundsKM medianP75P90P95
PFBS1060%49
2024-03-18
12.31–13.516.7114049
PFBA1040%13
2024-03-18
4.31–7.31<MRL9.71213
PFHpA1020%14
2024-03-18
2.5–4.9<MRL<MRL1114
PFHxA1020%28
2024-03-18
5.2–7.6<MRL<MRL2428
PFHxS1020%4.7
2024-03-18
0.89–3.29<MRL<MRL4.24.7
PFOA1020%35
2024-03-18
6.4–9.6<MRL<MRL2935
PFOS1020%18
2024-03-18
3.3–6.5<MRL<MRL1518
PFPeA1020%30
2024-03-18
5.5–7.9<MRL<MRL2530

Never detected (22): 11Cl-PF3OUdS, 4:2 FTS, 6:2 FTS, 8:2 FTS, 9Cl-PF3ONS, ADONA, HFPO-DA, NEtFOSAA, NFDHA, NMeFOSAA, PFDA, PFDoA, PFEESA, PFHpS, PFMBA, PFMPA, PFNA, PFPeS, PFTA, PFTrDA, PFUnA, lithium.

Left-censored Kaplan–Meier statistics (Helsel 2005; Helsel & Lee 2006, NADA for R). Units: ppt; lithium µg/L. Each compound has one reporting limit, so the Kaplan–Meier mean equals the upper mean bound (non-detects at the MRL); the lower bound sets non-detects to 0. “<MRL” = the percentile falls below the reporting limit and cannot be estimated. These describe this system's UCMR 5 samples, not population estimates.

Sources

  • EPA UCMR 5 occurrence data text files (UCMR5_All.txt; samples 2023-01-09 to 2026-05-12; data summary dated Jul 2026)
  • EPA SDWIS via ECHO SDWA downloads, quarter 2026Q3
  • EPA Public Water System Service Areas v3 (Mar 2026)
  • US Census Bureau cartographic boundary counties 1:500k, 2024
  • EPA/USGS NHDPlus V2 (medium resolution) flowlines, Strahler order 2+

Data build e2816911520e · 2026-10-18T04:08Z · UCMR 5 release Jul2026 · SDWIS 2026Q3. Data and methods.