Laurens County W&S Comm (Sc3020001)

PFAS monitoring results for a public water system in South Carolina

SC3020001UCMR 5EPA monitoring data
7.5Highest PFOA result, ppt
8.7Highest PFOS result, ppt
9.582Highest Hazard Index
360Results
PWSID
SC3020001
State
South Carolina
System type
community water system (CWS)
Population served
44,866
City
Laurens
Counties
Greenville County, Laurens County
Primary source water
surface water
UCMR 5 sampling
2023-12-17 to 2025-08-26 · 3 entry point(s) · water types: SW
Service-area boundary
EPA-modeled (Random Forest) — approximate: estimated by EPA with a statistical model, not a surveyed service area

Hazard Index ≥ 3 × its limit highest single result
Hazard Index ≥ 3 × its limit worst entry-point average

These are monitoring results collected under EPA's Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) at entry points, where treated water enters the distribution system; they are not tap-water samples. They are not compliance determinations: compliance with EPA's 2024 PFAS limits is judged on running annual averages of compliance monitoring, required from 2029, so a single UCMR 5 result at or above a limit is not a violation. “< MRL” means the compound was not quantified at EPA's minimum reporting level; it does not mean zero.

Water purchased from

Seller results are the seller's own entry-point samples, not measurements of this system's water. This system's own samples (below) may reflect purchased water, its own sources, or both.

Compared with EPA's 2024 values

Highest single resultWorst entry-point average*Limit
PFOA (ppt)7.54.974
PFOS (ppt)8.78.054
Hazard Index9.5823.5141.0†

“<MRL” = every result for the compound was below its reporting limit. * Mean of all samples at each entry point with non-detects = 0 (EPA compliance convention; the Hazard Index also uses non-detects = 0); a screening comparison, not a formal running annual average. † Rescission proposed May 2026. PFOA/PFOS MCL 4 ppt (2024 NPDWR, in effect). PFHxS, PFNA, HFPO-DA (10 ppt each) and the Hazard Index (1.0) are 2024 NPDWR values; EPA proposed rescinding them on 18 May 2026 (comment period closed 20 Jul 2026).

No South Carolina PFAS drinking-water standard in effect or proposed as of 2026-10-17: No state PFAS drinking-water standard; H. 3116 and H. 5572 (2025-26) pending, not enacted.

Sampling history

Sampled 2023-12-17 to 2025-08-26 · 3 entry point(s) · water types: SW · 13 sampling visits. PFAS in ppt (ng/L).

DateEntry pointEventPFOAPFOSHIOther detections
2023-12-17Clinton - Connection (SW)SE176.10.317PFBA 7.2, PFHpA 3.4, PFHxA 19.3, PFPeA 23.7
2023-12-18Greenville - Connection (SW)SE1<4<40none
2023-12-18Lake Greenwood WTF (SW)SE167.81.252PFHpA 3.2, PFHxA 5.8, PFPeA 7.3
2024-03-19Clinton - Connection (SW)SE2<4<40.003PFHxA 3.3, PFPeA 3.9
2024-03-19Greenville - Connection (SW)SE2<4<40none
2024-03-19Lake Greenwood WTF (SW)SE247.12.27none
2024-05-30Clinton - Connection (SW)SE3<44.10.504PFHxA 4.1, PFPeA 5.6
2024-05-30Greenville - Connection (SW)SE3<4<40none
2024-05-30Lake Greenwood WTF (SW)SE34.88.70.952PFHxA 4, PFPeA 3.8
2024-06-26Clinton - Connection (SW)SE3n/an/an/anone
2025-08-26Clinton - Connection (SW)SE47.570.317PFHpA 3.3, PFHxA 7.6, PFPeA 8.9
2025-08-26Greenville - Connection (SW)SE4<4<40none
2025-08-26Lake Greenwood WTF (SW)SE45.18.69.582PFHxA 6.4, PFPeA 6.8

“<4” = not detected at the reporting limit shown; “n/a” = not analyzed in that sample. Highlighted = at or above the 4 ppt MCL. HI computed per sample with non-detects as 0. Other detections lists every other quantified compound (lithium in µg/L).

All results by entry point

360 results. Each column is one sampling visit (date and UCMR 5 sample event). A number is a measured concentration; “< 4” = below the minimum reporting level shown; “–” = not analyzed in that visit. PFAS in ppt (ng/L); lithium in µg/L.

Clinton - Connection facility 30103 · sample point P30103 · surface water

CompoundMRL2023-12-17
SE1
2024-03-19
SE2
2024-05-30
SE3
2024-06-26
SE3
2025-08-26
SE4
HFPO-DA5 ppt< 5< 55–< 5
PFBA5 ppt7.2< 5< 5–< 5
PFBS3 ppt146.37.4–14.3
PFHpA3 ppt3.4< 3< 3–3.3
PFHxA3 ppt19.33.34.1–7.6
PFHxS3 ppt3.1< 3< 3–3.1
PFOA4 ppt7< 4< 4–7.5
PFOS4 ppt6.1< 44.1–7
PFPeA3 ppt23.73.95.6–8.9
11Cl-PF3OUdS5 ppt< 5< 5< 5–< 5
4:2 FTS3 ppt< 3< 3< 3–< 3
6:2 FTS5 ppt< 5< 5< 5–< 5
8:2 FTS5 ppt< 5< 5< 5–< 5
9Cl-PF3ONS2 ppt< 2< 2< 2–< 2
ADONA3 ppt< 3< 3< 3–< 3
NEtFOSAA5 ppt< 5< 5–< 5< 5
NFDHA20 ppt< 20< 20< 20–< 20
NMeFOSAA6 ppt< 6< 6–< 6< 6
PFDA3 ppt< 3< 3< 3–< 3
PFDoA3 ppt< 3< 3< 3–< 3
PFEESA3 ppt< 3< 3< 3–< 3
PFHpS3 ppt< 3< 3< 3–< 3
PFMBA3 ppt< 3< 3< 3–< 3
PFMPA4 ppt< 4< 4< 4–< 4
PFNA4 ppt< 4< 4< 4–< 4
PFPeS4 ppt< 4< 4< 4–< 4
PFTA8 ppt< 8< 8–< 8< 8
PFTrDA7 ppt< 7< 7–< 7< 7
PFUnA2 ppt< 2< 2< 2–< 2
lithium9 µg/L< 9< 9< 9–< 9

Greenville - Connection facility 30104 · sample point P30104 · surface water

CompoundMRL2023-12-18
SE1
2024-03-19
SE2
2024-05-30
SE3
2025-08-26
SE4
11Cl-PF3OUdS5 ppt< 5< 5< 5< 5
4:2 FTS3 ppt< 3< 3< 3< 3
6:2 FTS5 ppt< 5< 5< 5< 5
8:2 FTS5 ppt< 5< 5< 5< 5
9Cl-PF3ONS2 ppt< 2< 2< 2< 2
ADONA3 ppt< 3< 3< 3< 3
HFPO-DA5 ppt< 5< 5< 5< 5
NEtFOSAA5 ppt< 5< 5< 5< 5
NFDHA20 ppt< 20< 20< 20< 20
NMeFOSAA6 ppt< 6< 6< 6< 6
PFBA5 ppt< 5< 5< 5< 5
PFBS3 ppt< 3< 3< 3< 3
PFDA3 ppt< 3< 3< 3< 3
PFDoA3 ppt< 3< 3< 3< 3
PFEESA3 ppt< 3< 3< 3< 3
PFHpA3 ppt< 3< 3< 3< 3
PFHpS3 ppt< 3< 3< 3< 3
PFHxA3 ppt< 3< 3< 3< 3
PFHxS3 ppt< 3< 3< 3< 3
PFMBA3 ppt< 3< 3< 3< 3
PFMPA4 ppt< 4< 4< 4< 4
PFNA4 ppt< 4< 4< 4< 4
PFOA4 ppt< 4< 4< 4< 4
PFOS4 ppt< 4< 4< 4< 4
PFPeA3 ppt< 3< 3< 3< 3
PFPeS4 ppt< 4< 4< 4< 4
PFTA8 ppt< 8< 8< 8< 8
PFTrDA7 ppt< 7< 7< 7< 7
PFUnA2 ppt< 2< 2< 2< 2
lithium9 µg/L< 9< 9< 9< 9

Lake Greenwood WTF facility 30105 · sample point 30105 · surface water

CompoundMRL2023-12-18
SE1
2024-03-19
SE2
2024-05-30
SE3
2025-08-26
SE4
HFPO-DA5 ppt12.522.79.595.8
PFBS3 ppt5< 33.14
PFHpA3 ppt3.2< 3< 3< 3
PFHxA3 ppt5.8< 346.4
PFOA4 ppt644.85.1
PFOS4 ppt7.87.18.78.6
PFPeA3 ppt7.3< 33.86.8
11Cl-PF3OUdS5 ppt< 5< 5< 5< 5
4:2 FTS3 ppt< 3< 3< 3< 3
6:2 FTS5 ppt< 5< 5< 5< 5
8:2 FTS5 ppt< 5< 5< 5< 5
9Cl-PF3ONS2 ppt< 2< 2< 2< 2
ADONA3 ppt< 3< 3< 3< 3
NEtFOSAA5 ppt< 5< 5< 5< 5
NFDHA20 ppt< 20< 20< 20< 20
NMeFOSAA6 ppt< 6< 6< 6< 6
PFBA5 ppt< 5< 5< 5< 5
PFDA3 ppt< 3< 3< 3< 3
PFDoA3 ppt< 3< 3< 3< 3
PFEESA3 ppt< 3< 3< 3< 3
PFHpS3 ppt< 3< 3< 3< 3
PFHxS3 ppt< 3< 3< 3< 3
PFMBA3 ppt< 3< 3< 3< 3
PFMPA4 ppt< 4< 4< 4< 4
PFNA4 ppt< 4< 4< 4< 4
PFPeS4 ppt< 4< 4< 4< 4
PFTA8 ppt< 8< 8< 8< 8
PFTrDA7 ppt< 7< 7< 7< 7
PFUnA2 ppt< 2< 2< 2< 2
lithium9 µg/L< 9< 9< 9< 9

Statistics by compound

CompoundResultsDetectedHighest (date)Mean boundsKM medianP75P90P95
PFBS1258%14.3
2025-08-26
4.51–5.763.16.31414.3
PFHxA1258%19.3
2023-12-17
4.21–5.463.35.87.619.3
PFOS1258%8.7
2024-05-30
4.12–5.784.17.18.68.7
PFPeA1258%23.7
2023-12-17
5–6.253.86.88.923.7
PFOA1250%7.5
2025-08-26
2.87–4.87<MRL5.177.5
HFPO-DA1242%95.8
2025-08-26
12.12–15.04<MRL9.522.795.8
PFHpA1225%3.4
2023-12-17
0.82–3.08<MRL<MRL3.33.4
PFHxS1217%3.1
2023-12-17
0.52–3.02<MRL<MRL3.13.1
PFBA128%7.2
2023-12-17
0.6–5.18<MRL<MRL<MRL7.2

Never detected (21): 11Cl-PF3OUdS, 4:2 FTS, 6:2 FTS, 8:2 FTS, 9Cl-PF3ONS, ADONA, NEtFOSAA, NFDHA, NMeFOSAA, PFDA, PFDoA, PFEESA, PFHpS, PFMBA, PFMPA, PFNA, PFPeS, PFTA, PFTrDA, PFUnA, lithium.

Left-censored Kaplan–Meier statistics (Helsel 2005; Helsel & Lee 2006, NADA for R). Units: ppt; lithium µg/L. Each compound has one reporting limit, so the Kaplan–Meier mean equals the upper mean bound (non-detects at the MRL); the lower bound sets non-detects to 0. “<MRL” = the percentile falls below the reporting limit and cannot be estimated. These describe this system's UCMR 5 samples, not population estimates.

Sources

  • EPA UCMR 5 occurrence data text files (UCMR5_All.txt; samples 2023-01-09 to 2026-06-15; data summary dated Jul 2026)
  • EPA SDWIS via ECHO SDWA downloads, quarter 2026Q3
  • EPA Public Water System Service Areas v3 (Mar 2026)
  • US Census Bureau cartographic boundary counties 1:500k, 2024
  • EPA/USGS NHDPlus V2 (medium resolution) flowlines, Strahler order 2+

Data build 04c4b5704fe9 · 2026-10-18T04:07Z · UCMR 5 release Jul2026 · SDWIS 2026Q3. Data and methods.