- PWSID
- NJ1611002
- State
- New Jersey
- System type
- community water system (CWS)
- Population served
- 9,327
- City
- Ringwood
- Counties
- Passaic County
- Primary source water
- surface water (purchased)
- UCMR 5 sampling
- 2025-01-15 to 2025-10-14 · 4 entry point(s) · water types: GW;SW
- Service-area boundary
- authoritative
PFOA ≥ 3 × its limit highest single result
PFOA 1–3 × its limit worst entry-point average
Open on the New Jersey map · All New Jersey systems · All results
These are monitoring results collected under EPA's Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) at entry points, where treated water enters the distribution system; they are not tap-water samples. They are not compliance determinations: compliance with EPA's 2024 PFAS limits is judged on running annual averages of compliance monitoring, required from 2029, so a single UCMR 5 result at or above a limit is not a violation. “< MRL” means the compound was not quantified at EPA's minimum reporting level; it does not mean zero.
Water purchased from
- Passaic Valley Water Commission (NJ1605002)
Seller's highest results: PFOA 11.5 ppt · PFOS 7.7 ppt · HI 0.322 · detected: PFBA;PFBS;PFHpA;PFHxA;PFHxS;PFOA;PFOS;PFPeA
Seller results are the seller's own entry-point samples, not measurements of this system's water. This system's own samples (below) may reflect purchased water, its own sources, or both.
Compared with EPA's 2024 values
| Highest single result | Worst entry-point average* | Limit | |
|---|---|---|---|
| PFOA (ppt) | 12.3 | 11.5 | 4 |
| PFOS (ppt) | 8.8 | 8.4 | 4 |
| Hazard Index | 0.312 | 0.307 | 1.0† |
“<MRL” = every result for the compound was below its reporting limit. * Mean of all samples at each entry point with non-detects = 0 (EPA compliance convention; the Hazard Index also uses non-detects = 0); a screening comparison, not a formal running annual average. † Rescission proposed May 2026. PFOA/PFOS MCL 4 ppt (2024 NPDWR, in effect). PFHxS, PFNA, HFPO-DA (10 ppt each) and the Hazard Index (1.0) are 2024 NPDWR values; EPA proposed rescinding them on 18 May 2026 (comment period closed 20 Jul 2026).
Compared with New Jersey standards
| Highest single result | Worst entry-point average* | New Jersey | |
|---|---|---|---|
| PFNA (ppt) | 0 | 0 | 13 |
| PFOA (ppt) | 12.3 | 11.5 | 14 |
| PFOS (ppt) | 8.8 | 8.4 | 13 |
Sum standards add the listed compounds within each sample (non-detects = 0). State compliance is normally judged on averages over time; these are screening comparisons.
Sampling history
Sampled 2025-01-15 to 2025-10-14 · 4 entry point(s) · water types: GW;SW · 11 sampling visits. PFAS in ppt (ng/L).
| Date | Entry point | Event | PFOA | PFOS | HI | Other detections |
|---|---|---|---|---|---|---|
| 2025-01-15 | Connection to Passaic Water (SW) | SE1 | 10.8 | 6.8 | 0.002 | PFBA 5.2, PFHpA 3.6, PFHxA 8.6, PFPeA 9.4 |
| 2025-01-15 | RINGWOOD WATER DEPARTMENT Beattie Lane (GW) | SE1 | 10.6 | 6.7 | 0.002 | PFBA 5.2, PFHpA 3.6, PFHxA 8.7, PFPeA 9.7 |
| 2025-01-15 | RINGWOOD WATER DEPARTMENT Brooksyde (GW) | SE1 | 12.3 | 8.8 | 0.303 | PFHpA 3.2, PFHxA 6.8, PFPeA 6.9 |
| 2025-01-15 | RINGWOOD WATER DEPARTMENT Valley Road (GW) | SE1 | 5.8 | 5 | 0.002 | none |
| 2025-04-14 | Connection to Passaic Water (SW) | SE2 | n/a | n/a | 0 | none |
| 2025-07-14 | Connection to Passaic Water (SW) | SE3 | 5.4 | 5.2 | 0 | none |
| 2025-07-14 | RINGWOOD WATER DEPARTMENT Beattie Lane (GW) | SE2 | 5.9 | 6.2 | 0 | none |
| 2025-07-14 | RINGWOOD WATER DEPARTMENT Brooksyde (GW) | SE2 | 10.7 | 8 | 0.312 | PFHxA 7.1, PFPeA 7.6 |
| 2025-08-26 | RINGWOOD WATER DEPARTMENT Valley Road (GW) | SE2 | 7 | 5.9 | 0.002 | none |
| 2025-09-09 | Connection to Passaic Water (SW) | SE2 | 5.5 | 6.4 | 0 | none |
| 2025-10-14 | Connection to Passaic Water (SW) | SE4 | 5.6 | 6.1 | 0 | none |
“<4” = not detected at the reporting limit shown; “n/a” = not analyzed in that sample. Highlighted = at or above the 4 ppt MCL. HI computed per sample with non-detects as 0. Other detections lists every other quantified compound (lithium in µg/L).
All results by entry point
300 results. Each column is one sampling visit (date and UCMR 5 sample event). A number is a measured concentration; “< 4” = below the minimum reporting level shown; “–” = not analyzed in that visit. PFAS in ppt (ng/L); lithium in µg/L.
Connection to Passaic Water facility CC001001 · sample point CC001001 · surface water
| Compound | MRL | 2025-01-15 SE1 | 2025-04-14 SE2 | 2025-07-14 SE3 | 2025-09-09 SE2 | 2025-10-14 SE4 |
|---|---|---|---|---|---|---|
| PFBA | 5 ppt | 5.2 | < 5 | < 5 | – | < 5 |
| PFBS | 3 ppt | 4.1 | – | < 3 | < 3 | < 3 |
| PFHpA | 3 ppt | 3.6 | < 3 | < 3 | – | < 3 |
| PFHxA | 3 ppt | 8.6 | – | < 3 | < 3 | < 3 |
| PFOA | 4 ppt | 10.8 | – | 5.4 | 5.5 | 5.6 |
| PFOS | 4 ppt | 6.8 | – | 5.2 | 6.4 | 6.1 |
| PFPeA | 3 ppt | 9.4 | – | < 3 | < 3 | < 3 |
| 11Cl-PF3OUdS | 5 ppt | < 5 | < 5 | < 5 | – | < 5 |
| 4:2 FTS | 3 ppt | < 3 | < 3 | < 3 | – | < 3 |
| 6:2 FTS | 5 ppt | < 5 | < 5 | < 5 | – | < 5 |
| 8:2 FTS | 5 ppt | < 5 | < 5 | < 5 | – | < 5 |
| 9Cl-PF3ONS | 2 ppt | < 2 | < 2 | < 2 | – | < 2 |
| ADONA | 3 ppt | < 3 | < 3 | < 3 | – | < 3 |
| HFPO-DA | 5 ppt | < 5 | < 5 | < 5 | – | < 5 |
| NEtFOSAA | 5 ppt | < 5 | < 5 | < 5 | – | < 5 |
| NFDHA | 20 ppt | < 20 | < 20 | < 20 | – | < 20 |
| NMeFOSAA | 6 ppt | < 6 | < 6 | < 6 | – | < 6 |
| PFDA | 3 ppt | < 3 | < 3 | < 3 | – | < 3 |
| PFDoA | 3 ppt | < 3 | < 3 | < 3 | – | < 3 |
| PFEESA | 3 ppt | < 3 | < 3 | < 3 | – | < 3 |
| PFHpS | 3 ppt | < 3 | < 3 | < 3 | – | < 3 |
| PFHxS | 3 ppt | < 3 | < 3 | < 3 | – | < 3 |
| PFMBA | 3 ppt | < 3 | < 3 | < 3 | – | < 3 |
| PFMPA | 4 ppt | < 4 | < 4 | < 4 | – | < 4 |
| PFNA | 4 ppt | < 4 | < 4 | < 4 | – | < 4 |
| PFPeS | 4 ppt | < 4 | < 4 | < 4 | – | < 4 |
| PFTA | 8 ppt | < 8 | < 8 | < 8 | – | < 8 |
| PFTrDA | 7 ppt | < 7 | < 7 | < 7 | – | < 7 |
| PFUnA | 2 ppt | < 2 | < 2 | < 2 | – | < 2 |
| lithium | 9 µg/L | < 9 | < 9 | < 9 | – | < 9 |
RINGWOOD WATER DEPARTMENT Beattie Lane facility TP002003 · sample point TP002003 · groundwater
| Compound | MRL | 2025-01-15 SE1 | 2025-07-14 SE2 |
|---|---|---|---|
| PFBA | 5 ppt | 5.2 | < 5 |
| PFBS | 3 ppt | 4 | < 3 |
| PFHpA | 3 ppt | 3.6 | < 3 |
| PFHxA | 3 ppt | 8.7 | < 3 |
| PFOA | 4 ppt | 10.6 | 5.9 |
| PFOS | 4 ppt | 6.7 | 6.2 |
| PFPeA | 3 ppt | 9.7 | < 3 |
| 11Cl-PF3OUdS | 5 ppt | < 5 | < 5 |
| 4:2 FTS | 3 ppt | < 3 | < 3 |
| 6:2 FTS | 5 ppt | < 5 | < 5 |
| 8:2 FTS | 5 ppt | < 5 | < 5 |
| 9Cl-PF3ONS | 2 ppt | < 2 | < 2 |
| ADONA | 3 ppt | < 3 | < 3 |
| HFPO-DA | 5 ppt | < 5 | < 5 |
| NEtFOSAA | 5 ppt | < 5 | < 5 |
| NFDHA | 20 ppt | < 20 | < 20 |
| NMeFOSAA | 6 ppt | < 6 | < 6 |
| PFDA | 3 ppt | < 3 | < 3 |
| PFDoA | 3 ppt | < 3 | < 3 |
| PFEESA | 3 ppt | < 3 | < 3 |
| PFHpS | 3 ppt | < 3 | < 3 |
| PFHxS | 3 ppt | < 3 | < 3 |
| PFMBA | 3 ppt | < 3 | < 3 |
| PFMPA | 4 ppt | < 4 | < 4 |
| PFNA | 4 ppt | < 4 | < 4 |
| PFPeS | 4 ppt | < 4 | < 4 |
| PFTA | 8 ppt | < 8 | < 8 |
| PFTrDA | 7 ppt | < 7 | < 7 |
| PFUnA | 2 ppt | < 2 | < 2 |
| lithium | 9 µg/L | < 9 | < 9 |
RINGWOOD WATER DEPARTMENT Brooksyde facility TP001001 · sample point TP001001 · groundwater
| Compound | MRL | 2025-01-15 SE1 | 2025-07-14 SE2 |
|---|---|---|---|
| PFBS | 3 ppt | 5.2 | 4 |
| PFHpA | 3 ppt | 3.2 | < 3 |
| PFHxA | 3 ppt | 6.8 | 7.1 |
| PFHxS | 3 ppt | 3 | 3.1 |
| PFOA | 4 ppt | 12.3 | 10.7 |
| PFOS | 4 ppt | 8.8 | 8 |
| PFPeA | 3 ppt | 6.9 | 7.6 |
| 11Cl-PF3OUdS | 5 ppt | < 5 | < 5 |
| 4:2 FTS | 3 ppt | < 3 | < 3 |
| 6:2 FTS | 5 ppt | < 5 | < 5 |
| 8:2 FTS | 5 ppt | < 5 | < 5 |
| 9Cl-PF3ONS | 2 ppt | < 2 | < 2 |
| ADONA | 3 ppt | < 3 | < 3 |
| HFPO-DA | 5 ppt | < 5 | < 5 |
| NEtFOSAA | 5 ppt | < 5 | < 5 |
| NFDHA | 20 ppt | < 20 | < 20 |
| NMeFOSAA | 6 ppt | < 6 | < 6 |
| PFBA | 5 ppt | < 5 | < 5 |
| PFDA | 3 ppt | < 3 | < 3 |
| PFDoA | 3 ppt | < 3 | < 3 |
| PFEESA | 3 ppt | < 3 | < 3 |
| PFHpS | 3 ppt | < 3 | < 3 |
| PFMBA | 3 ppt | < 3 | < 3 |
| PFMPA | 4 ppt | < 4 | < 4 |
| PFNA | 4 ppt | < 4 | < 4 |
| PFPeS | 4 ppt | < 4 | < 4 |
| PFTA | 8 ppt | < 8 | < 8 |
| PFTrDA | 7 ppt | < 7 | < 7 |
| PFUnA | 2 ppt | < 2 | < 2 |
| lithium | 9 µg/L | < 9 | < 9 |
RINGWOOD WATER DEPARTMENT Valley Road facility TP003022 · sample point TP003022 · groundwater
| Compound | MRL | 2025-01-15 SE1 | 2025-08-26 SE2 |
|---|---|---|---|
| PFBS | 3 ppt | 3 | 3.3 |
| PFOA | 4 ppt | 5.8 | 7 |
| PFOS | 4 ppt | 5 | 5.9 |
| 11Cl-PF3OUdS | 5 ppt | < 5 | < 5 |
| 4:2 FTS | 3 ppt | < 3 | < 3 |
| 6:2 FTS | 5 ppt | < 5 | < 5 |
| 8:2 FTS | 5 ppt | < 5 | < 5 |
| 9Cl-PF3ONS | 2 ppt | < 2 | < 2 |
| ADONA | 3 ppt | < 3 | < 3 |
| HFPO-DA | 5 ppt | < 5 | < 5 |
| NEtFOSAA | 5 ppt | < 5 | < 5 |
| NFDHA | 20 ppt | < 20 | < 20 |
| NMeFOSAA | 6 ppt | < 6 | < 6 |
| PFBA | 5 ppt | < 5 | < 5 |
| PFDA | 3 ppt | < 3 | < 3 |
| PFDoA | 3 ppt | < 3 | < 3 |
| PFEESA | 3 ppt | < 3 | < 3 |
| PFHpA | 3 ppt | < 3 | < 3 |
| PFHpS | 3 ppt | < 3 | < 3 |
| PFHxA | 3 ppt | < 3 | < 3 |
| PFHxS | 3 ppt | < 3 | < 3 |
| PFMBA | 3 ppt | < 3 | < 3 |
| PFMPA | 4 ppt | < 4 | < 4 |
| PFNA | 4 ppt | < 4 | < 4 |
| PFPeA | 3 ppt | < 3 | < 3 |
| PFPeS | 4 ppt | < 4 | < 4 |
| PFTA | 8 ppt | < 8 | < 8 |
| PFTrDA | 7 ppt | < 7 | < 7 |
| PFUnA | 2 ppt | < 2 | < 2 |
| lithium | 9 µg/L | < 9 | < 9 |
Statistics by compound
| Compound | Results | Detected | Highest (date) | Mean bounds | KM median | P75 | P90 | P95 |
|---|---|---|---|---|---|---|---|---|
| PFOA | 10 | 100% | 12.3 2025-01-15 | 7.96–7.96 | 5.9 | 10.7 | 10.8 | 12.3 |
| PFOS | 10 | 100% | 8.8 2025-01-15 | 6.51–6.51 | 6.2 | 6.8 | 8 | 8.8 |
| PFBS | 10 | 60% | 5.2 2025-01-15 | 2.36–3.56 | 3 | 4 | 4.1 | 5.2 |
| PFHxA | 10 | 40% | 8.7 2025-01-15 | 3.12–4.92 | <MRL | 7.1 | 8.6 | 8.7 |
| PFPeA | 10 | 40% | 9.7 2025-01-15 | 3.36–5.16 | <MRL | 7.6 | 9.4 | 9.7 |
| PFHpA | 10 | 30% | 3.6 2025-01-15 | 1.04–3.14 | <MRL | 3.2 | 3.6 | 3.6 |
| PFBA | 10 | 20% | 5.2 2025-01-15 | 1.04–5.04 | <MRL | <MRL | 5.2 | 5.2 |
| PFHxS | 10 | 20% | 3.1 2025-07-14 | 0.61–3.01 | <MRL | <MRL | 3 | 3.1 |
Never detected (22): 11Cl-PF3OUdS, 4:2 FTS, 6:2 FTS, 8:2 FTS, 9Cl-PF3ONS, ADONA, HFPO-DA, NEtFOSAA, NFDHA, NMeFOSAA, PFDA, PFDoA, PFEESA, PFHpS, PFMBA, PFMPA, PFNA, PFPeS, PFTA, PFTrDA, PFUnA, lithium.
Left-censored Kaplan–Meier statistics (Helsel 2005; Helsel & Lee 2006, NADA for R). Units: ppt; lithium µg/L. Each compound has one reporting limit, so the Kaplan–Meier mean equals the upper mean bound (non-detects at the MRL); the lower bound sets non-detects to 0. “<MRL” = the percentile falls below the reporting limit and cannot be estimated. These describe this system's UCMR 5 samples, not population estimates.
Sources
- EPA UCMR 5 occurrence data text files (UCMR5_All.txt; samples 2023-01-09 to 2026-05-29; data summary dated Jul 2026)
- EPA SDWIS via ECHO SDWA downloads, quarter 2026Q3
- EPA Public Water System Service Areas v3 (Mar 2026)
- US Census Bureau cartographic boundary counties 1:500k, 2024
- EPA/USGS NHDPlus V2 (medium resolution) flowlines, Strahler order 2+
Data build 0c4398dd12d6 · 2026-10-18T04:09Z · UCMR 5 release Jul2026 · SDWIS 2026Q3. Data and methods.