Benson, Town Of

PFAS monitoring results for a public water system in North Carolina

NC0351025UCMR 5EPA monitoring data
8.9Highest PFOA result, ppt
15Highest PFOS result, ppt
0.47Highest Hazard Index
240Results
PWSID
NC0351025
State
North Carolina
System type
community water system (CWS)
Population served
4,802
City
Benson
Counties
Johnston County
Primary source water
surface water (purchased)
UCMR 5 sampling
2024-03-12 to 2024-12-10 · 2 entry point(s) · water types: SW
Service-area boundary
authoritative

PFOS ≥ 3 × its limit highest single result
PFOS 1–3 × its limit worst entry-point average

These are monitoring results collected under EPA's Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) at entry points, where treated water enters the distribution system; they are not tap-water samples. They are not compliance determinations: compliance with EPA's 2024 PFAS limits is judged on running annual averages of compliance monitoring, required from 2029, so a single UCMR 5 result at or above a limit is not a violation. “< MRL” means the compound was not quantified at EPA's minimum reporting level; it does not mean zero.

Water purchased from

  • Dunn, City Of (NC0343010)
    Seller's highest results: PFOA 12 ppt · PFOS 14.4 ppt · HI 0.527 · detected: PFBA;PFBS;PFHpA;PFHxA;PFHxS;PFOA;PFOS;PFPeA
  • Johnston Co-West (NC0351070)
    Seller's highest results: PFOA 7.6 ppt · PFOS 14.1 ppt · HI 0.532 · detected: PFBA;PFBS;PFHpA;PFHxA;PFHxS;PFOA;PFOS;PFPeA
  • Johnston Co-East (NC4051018)
    Seller's highest results: PFOA 7.7 ppt · PFOS 9.7 ppt · HI 0.383 · detected: PFBA;PFBS;PFHpA;PFHxA;PFHxS;PFOA;PFOS;PFPeA

Seller results are the seller's own entry-point samples, not measurements of this system's water. This system's own samples (below) may reflect purchased water, its own sources, or both.

Compared with EPA's 2024 values

Highest single resultWorst entry-point average*Limit
PFOA (ppt)8.97.424
PFOS (ppt)1511.94
Hazard Index0.470.2451.0†

“<MRL” = every result for the compound was below its reporting limit. * Mean of all samples at each entry point with non-detects = 0 (EPA compliance convention; the Hazard Index also uses non-detects = 0); a screening comparison, not a formal running annual average. † Rescission proposed May 2026. PFOA/PFOS MCL 4 ppt (2024 NPDWR, in effect). PFHxS, PFNA, HFPO-DA (10 ppt each) and the Hazard Index (1.0) are 2024 NPDWR values; EPA proposed rescinding them on 18 May 2026 (comment period closed 20 Jul 2026).

No North Carolina PFAS drinking-water standard in effect or proposed as of 2026-10-17: No state PFAS drinking-water MCL in effect; S.B. 384 (2025) filed, not enacted; DEQ implementing federal NPDWR.

Sampling history

Sampled 2024-03-12 to 2024-12-10 · 2 entry point(s) · water types: SW · 14 sampling visits. PFAS in ppt (ng/L).

DateEntry pointEventPFOAPFOSHIOther detections
2024-03-12Connection to Dunn (SW)SE1n/an/an/anone
2024-03-12Connection to Johnson Co. (SW)SE1n/an/an/anone
2024-04-22Connection to Dunn (SW)SE1n/an/an/anone
2024-07-08Connection to Dunn (SW)SE18.9150.334PFBA 7.3, PFHpA 4.8, PFHxA 12, PFPeA 11
2024-07-08Connection to Johnson Co. (SW)SE18.3120.303PFBA 7.8, PFHpA 4.8, PFHxA 11, PFPeA 12
2024-07-09Connection to Dunn (SW)SE2n/an/an/anone
2024-07-09Connection to Johnson Co. (SW)SE2n/an/an/anone
2024-08-14Connection to Johnson Co. (SW)SE2n/an/an/anone
2024-09-17Connection to Dunn (SW)SE36110.002PFBA 6.4, PFHpA 3.6, PFHxA 7.4, PFPeA 10
2024-09-17Connection to Johnson Co. (SW)SE37.4110.302PFBA 6.7, PFHpA 4.1, PFHxA 8.1, PFPeA 10
2024-09-23Connection to Dunn (SW)SE25.910.60PFBA 5.4, PFHxA 5.5, PFPeA 5.7
2024-10-22Connection to Johnson Co. (SW)SE26.19.10.002PFHpA 3, PFHxA 5.5, PFPeA 5.5
2024-12-10Connection to Dunn (SW)SE47.3110.47PFHpA 4.9, PFHxA 9.3, PFPeA 9.2
2024-12-10Connection to Johnson Co. (SW)SE47.9120.373PFBA 6.3, PFHpA 4.6, PFHxA 9.4, PFPeA 9.1

“<4” = not detected at the reporting limit shown; “n/a” = not analyzed in that sample. Highlighted = at or above the 4 ppt MCL. HI computed per sample with non-detects as 0. Other detections lists every other quantified compound (lithium in µg/L).

All results by entry point

240 results. Each column is one sampling visit (date and UCMR 5 sample event). A number is a measured concentration; “< 4” = below the minimum reporting level shown; “–” = not analyzed in that visit. PFAS in ppt (ng/L); lithium in µg/L.

Connection to Dunn facility S01 · sample point EP1 · surface water

CompoundMRL2024-03-12
SE1
2024-04-22
SE1
2024-07-08
SE1
2024-07-09
SE2
2024-09-17
SE3
2024-09-23
SE2
2024-12-10
SE4
PFBA5 ppt––7.3–6.45.4< 5
PFBS3 ppt––7.2–3.6< 3< 3
PFHpA3 ppt––4.8–3.6< 34.9
PFHxA3 ppt––12–7.45.59.3
PFHxS3 ppt––3.3–< 3< 34.7
PFOA4 ppt––8.9–65.97.3
PFOS4 ppt––15–1110.611
PFPeA3 ppt––11–105.79.2
11Cl-PF3OUdS5 ppt––< 5–< 5< 5< 5
4:2 FTS3 ppt––< 3–< 3< 3< 3
6:2 FTS5 ppt––< 5–< 5< 5< 5
8:2 FTS5 ppt––< 5–< 5< 5< 5
9Cl-PF3ONS2 ppt––< 2–< 2< 2< 2
ADONA3 ppt––< 3–< 3< 3< 3
HFPO-DA5 ppt––< 5–< 5< 5< 5
NEtFOSAA5 ppt–< 5–< 5< 5–< 5
NFDHA20 ppt––< 20–< 20< 20< 20
NMeFOSAA6 ppt–< 6–< 6< 6–< 6
PFDA3 ppt––< 3–< 3< 3< 3
PFDoA3 ppt––< 3–< 3< 3< 3
PFEESA3 ppt––< 3–< 3< 3< 3
PFHpS3 ppt––< 3–< 3< 3< 3
PFMBA3 ppt––< 3–< 3< 3< 3
PFMPA4 ppt––< 4–< 4< 4< 4
PFNA4 ppt––< 4–< 4< 4< 4
PFPeS4 ppt––< 4–< 4< 4< 4
PFTA8 ppt–< 8–< 8< 8–< 8
PFTrDA7 ppt–< 7–< 7< 7–< 7
PFUnA2 ppt––< 2–< 2< 2< 2
lithium9 µg/L< 9––< 9< 9–< 9

Connection to Johnson Co. facility S02 · sample point EP2 · surface water

CompoundMRL2024-03-12
SE1
2024-07-08
SE1
2024-07-09
SE2
2024-08-14
SE2
2024-09-17
SE3
2024-10-22
SE2
2024-12-10
SE4
PFBA5 ppt–7.8––6.7< 56.3
PFBS3 ppt–6.8––3.74.35.6
PFHpA3 ppt–4.8––4.134.6
PFHxA3 ppt–11––8.15.59.4
PFHxS3 ppt–3––3< 33.7
PFOA4 ppt–8.3––7.46.17.9
PFOS4 ppt–12––119.112
PFPeA3 ppt–12––105.59.1
11Cl-PF3OUdS5 ppt–< 5––< 5< 5< 5
4:2 FTS3 ppt–< 3––< 3< 3< 3
6:2 FTS5 ppt–< 5––< 5< 5< 5
8:2 FTS5 ppt–< 5––< 5< 5< 5
9Cl-PF3ONS2 ppt–< 2––< 2< 2< 2
ADONA3 ppt–< 3––< 3< 3< 3
HFPO-DA5 ppt–< 5––< 5< 5< 5
NEtFOSAA5 ppt< 5––< 5< 5–< 5
NFDHA20 ppt–< 20––< 20< 20< 20
NMeFOSAA6 ppt< 6––< 6< 6–< 6
PFDA3 ppt–< 3––< 3< 3< 3
PFDoA3 ppt–< 3––< 3< 3< 3
PFEESA3 ppt–< 3––< 3< 3< 3
PFHpS3 ppt–< 3––< 3< 3< 3
PFMBA3 ppt–< 3––< 3< 3< 3
PFMPA4 ppt–< 4––< 4< 4< 4
PFNA4 ppt–< 4––< 4< 4< 4
PFPeS4 ppt–< 4––< 4< 4< 4
PFTA8 ppt< 8––< 8< 8–< 8
PFTrDA7 ppt< 7––< 7< 7–< 7
PFUnA2 ppt–< 2––< 2< 2< 2
lithium9 µg/L< 9–< 9–< 9–< 9

Statistics by compound

CompoundResultsDetectedHighest (date)Mean boundsKM medianP75P90P95
PFHxA8100%12
2024-07-08
8.53–8.538.19.41212
PFOA8100%8.9
2024-07-08
7.22–7.227.37.98.98.9
PFOS8100%15
2024-07-08
11.46–11.4611121515
PFPeA8100%12
2024-07-08
9.06–9.069.2101212
PFHpA888%4.9
2024-12-10
3.73–4.14.14.84.94.9
PFBA875%7.8
2024-07-08
4.99–6.246.36.77.87.8
PFBS875%7.2
2024-07-08
3.9–4.653.75.67.27.2
PFHxS862%4.7
2024-12-10
2.21–3.3433.34.74.7

Never detected (22): 11Cl-PF3OUdS, 4:2 FTS, 6:2 FTS, 8:2 FTS, 9Cl-PF3ONS, ADONA, HFPO-DA, NEtFOSAA, NFDHA, NMeFOSAA, PFDA, PFDoA, PFEESA, PFHpS, PFMBA, PFMPA, PFNA, PFPeS, PFTA, PFTrDA, PFUnA, lithium.

Left-censored Kaplan–Meier statistics (Helsel 2005; Helsel & Lee 2006, NADA for R). Units: ppt; lithium µg/L. Each compound has one reporting limit, so the Kaplan–Meier mean equals the upper mean bound (non-detects at the MRL); the lower bound sets non-detects to 0. “<MRL” = the percentile falls below the reporting limit and cannot be estimated. These describe this system's UCMR 5 samples, not population estimates.

Sources

  • EPA UCMR 5 occurrence data text files (UCMR5_All.txt; samples 2023-01-09 to 2026-06-03; data summary dated Jul 2026)
  • EPA SDWIS via ECHO SDWA downloads, quarter 2026Q3
  • EPA Public Water System Service Areas v3 (Mar 2026)
  • US Census Bureau cartographic boundary counties 1:500k, 2024
  • EPA/USGS NHDPlus V2 (medium resolution) flowlines, Strahler order 2+

Data build 06b855374275 · 2026-10-18T04:10Z · UCMR 5 release Jul2026 · SDWIS 2026Q3. Data and methods.