Frusi Water Treatment Plant

PFAS monitoring results for a public water system in Kansas

KS2006114UCMR 5EPA monitoring data
21.1Highest PFOA result, ppt
8.8Highest PFOS result, ppt
2.014Highest Hazard Index
60Results
PWSID
KS2006114
State
Kansas
System type
community water system (CWS)
Population served
35,784
City
Fort Riley
Counties
Geary County, Riley County
Primary source water
groundwater
UCMR 5 sampling
2023-09-05 to 2024-03-18 · 1 entry point(s) · water types: GW
Service-area boundary
authoritative

PFOA ≥ 3 × its limit highest single result
PFOA ≥ 3 × its limit worst entry-point average

These are monitoring results collected under EPA's Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) at entry points, where treated water enters the distribution system; they are not tap-water samples. They are not compliance determinations: compliance with EPA's 2024 PFAS limits is judged on running annual averages of compliance monitoring, required from 2029, so a single UCMR 5 result at or above a limit is not a violation. “< MRL” means the compound was not quantified at EPA's minimum reporting level; it does not mean zero.

Compared with EPA's 2024 values

Highest single resultWorst entry-point average*Limit
PFOA (ppt)21.114.14
PFOS (ppt)8.84.44
Hazard Index2.0141.8831.0†

“<MRL” = every result for the compound was below its reporting limit. * Mean of all samples at each entry point with non-detects = 0 (EPA compliance convention; the Hazard Index also uses non-detects = 0); a screening comparison, not a formal running annual average. † Rescission proposed May 2026. PFOA/PFOS MCL 4 ppt (2024 NPDWR, in effect). PFHxS, PFNA, HFPO-DA (10 ppt each) and the Hazard Index (1.0) are 2024 NPDWR values; EPA proposed rescinding them on 18 May 2026 (comment period closed 20 Jul 2026).

No Kansas PFAS drinking-water standard in effect or proposed as of 2026-10-17: No state PFAS drinking-water standard; follows federal NPDWR (BCLP state survey, Jan 2026).

Sampling history

Sampled 2023-09-05 to 2024-03-18 · 1 entry point(s) · water types: GW · 3 sampling visits. PFAS in ppt (ng/L).

DateEntry pointEventPFOAPFOSHIOther detections
2023-09-05Main Post (8 Wells) (GW)SE1n/an/an/alithium 28 µg/L
2023-10-17Main Post (8 Wells) (GW)SE17.1<42.014PFHxA 9.2, PFPeA 16.5, PFPeS 4.4
2024-03-18Main Post (8 Wells) (GW)SE221.18.81.753PFHxA 5.1, PFPeA 6.2, PFPeS 4.2, lithium 30.9 µg/L

“<4” = not detected at the reporting limit shown; “n/a” = not analyzed in that sample. Highlighted = at or above the 4 ppt MCL. HI computed per sample with non-detects as 0. Other detections lists every other quantified compound (lithium in µg/L).

All results by entry point

60 results. Each column is one sampling visit (date and UCMR 5 sample event). A number is a measured concentration; “< 4” = below the minimum reporting level shown; “–” = not analyzed in that visit. PFAS in ppt (ng/L); lithium in µg/L.

Main Post (8 Wells) facility 00001 · sample point 00115759 · groundwater

CompoundMRL2023-09-05
SE1
2023-10-17
SE1
2024-03-18
SE2
PFBS3 ppt–6.96
PFHxA3 ppt–9.25.1
PFHxS3 ppt–20.117.5
PFOA4 ppt–7.121.1
PFOS4 ppt–< 48.8
PFPeA3 ppt–16.56.2
PFPeS4 ppt–4.44.2
11Cl-PF3OUdS5 ppt–< 5< 5
4:2 FTS3 ppt–< 3< 3
6:2 FTS5 ppt–< 5< 5
8:2 FTS5 ppt–< 5< 5
9Cl-PF3ONS2 ppt–< 2< 2
ADONA3 ppt–< 3< 3
HFPO-DA5 ppt–< 5< 5
NEtFOSAA5 ppt< 5–< 5
NFDHA20 ppt–< 20< 20
NMeFOSAA6 ppt< 6–< 6
PFBA5 ppt–< 5< 5
PFDA3 ppt–< 3< 3
PFDoA3 ppt–< 3< 3
PFEESA3 ppt–< 3< 3
PFHpA3 ppt–< 3< 3
PFHpS3 ppt–< 3< 3
PFMBA3 ppt–< 3< 3
PFMPA4 ppt–< 4< 4
PFNA4 ppt–< 4< 4
PFTA8 ppt< 8–< 8
PFTrDA7 ppt< 7–< 7
PFUnA2 ppt–< 2< 2
lithium9 µg/L28–30.9

Statistics by compound

CompoundResultsDetectedHighest (date)Mean boundsKM medianP75P90P95
PFBS2100%6.9
2023-10-17
6.45–6.45fewer than 4 results: raw values only
PFHxA2100%9.2
2023-10-17
7.15–7.15fewer than 4 results: raw values only
PFHxS2100%20.1
2023-10-17
18.8–18.8fewer than 4 results: raw values only
PFOA2100%21.1
2024-03-18
14.1–14.1fewer than 4 results: raw values only
PFPeA2100%16.5
2023-10-17
11.35–11.35fewer than 4 results: raw values only
PFPeS2100%4.4
2023-10-17
4.3–4.3fewer than 4 results: raw values only
lithium2100%30.9
2024-03-18
29.45–29.45fewer than 4 results: raw values only
PFOS250%8.8
2024-03-18
4.4–6.4fewer than 4 results: raw values only

Never detected (22): 11Cl-PF3OUdS, 4:2 FTS, 6:2 FTS, 8:2 FTS, 9Cl-PF3ONS, ADONA, HFPO-DA, NEtFOSAA, NFDHA, NMeFOSAA, PFBA, PFDA, PFDoA, PFEESA, PFHpA, PFHpS, PFMBA, PFMPA, PFNA, PFTA, PFTrDA, PFUnA.

Left-censored Kaplan–Meier statistics (Helsel 2005; Helsel & Lee 2006, NADA for R). Units: ppt; lithium µg/L. Each compound has one reporting limit, so the Kaplan–Meier mean equals the upper mean bound (non-detects at the MRL); the lower bound sets non-detects to 0. “<MRL” = the percentile falls below the reporting limit and cannot be estimated. These describe this system's UCMR 5 samples, not population estimates.

Sources

  • EPA UCMR 5 occurrence data text files (UCMR5_All.txt; samples 2023-01-06 to 2026-05-19; data summary dated Jul 2026)
  • EPA SDWIS via ECHO SDWA downloads, quarter 2026Q3
  • EPA Public Water System Service Areas v3 (Mar 2026)
  • US Census Bureau cartographic boundary counties 1:500k, 2024
  • EPA/USGS NHDPlus V2 (medium resolution) flowlines, Strahler order 2+

Data build e05f879c10ec · 2026-10-18T04:05Z · UCMR 5 release Jul2026 · SDWIS 2026Q3. Data and methods.