Citizens Water - Indianapolis

PFAS monitoring results for a public water system in Indiana

IN5249004UCMR 5EPA monitoring data
<MRLHighest PFOA result, ppt
<MRLHighest PFOS result, ppt
0.002Highest Hazard Index
780Results
PWSID
IN5249004
State
Indiana
System type
community water system (CWS)
Population served
880,345
City
Indianapolis
Counties
Boone County, Hamilton County, Hancock County, Hendricks County, Johnson County, Marion County, Morgan County, Shelby County
Primary source water
surface water
UCMR 5 sampling
2023-08-22 to 2024-08-23 · 9 entry point(s) · water types: GW;MX;SW
Service-area boundary
authoritative

Hazard Index below its limit highest single result
Hazard Index below its limit worst entry-point average

These are monitoring results collected under EPA's Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) at entry points, where treated water enters the distribution system; they are not tap-water samples. They are not compliance determinations: compliance with EPA's 2024 PFAS limits is judged on running annual averages of compliance monitoring, required from 2029, so a single UCMR 5 result at or above a limit is not a violation. “< MRL” means the compound was not quantified at EPA's minimum reporting level; it does not mean zero.

Water purchased from

Seller results are the seller's own entry-point samples, not measurements of this system's water. This system's own samples (below) may reflect purchased water, its own sources, or both.

Compared with EPA's 2024 values

Highest single resultWorst entry-point average*Limit
PFOA (ppt)<MRL04
PFOS (ppt)<MRL04
Hazard Index0.0020.0021.0†

“<MRL” = every result for the compound was below its reporting limit. * Mean of all samples at each entry point with non-detects = 0 (EPA compliance convention; the Hazard Index also uses non-detects = 0); a screening comparison, not a formal running annual average. † Rescission proposed May 2026. PFOA/PFOS MCL 4 ppt (2024 NPDWR, in effect). PFHxS, PFNA, HFPO-DA (10 ppt each) and the Hazard Index (1.0) are 2024 NPDWR values; EPA proposed rescinding them on 18 May 2026 (comment period closed 20 Jul 2026).

No Indiana PFAS drinking-water standard in effect or proposed as of 2026-10-17: No Indiana-specific PFAS drinking-water MCL; IDEM R2 PFAS levels are cleanup values, not drinking-water standards.

Sampling history

Sampled 2023-08-22 to 2024-08-23 · 9 entry point(s) · water types: GW;MX;SW · 27 sampling visits. PFAS in ppt (ng/L).

DateEntry pointEventPFOAPFOSHIOther detections
2023-08-22Treatment Plant #2 (SW)SE1<4<40none
2023-08-22Treatment Plant #5 (GW)SE1<4<40none
2023-08-22Treatment Plant #9 (GW)SE1<4<40none
2023-08-23Treatment Plant #1 (SW)SE1<4<40PFHxA 4.4, PFPeA 5.2
2023-08-23Treatment Plant #3 (SW)SE1<4<40PFBA 5, PFHxA 4.9, PFPeA 6.7
2023-08-23Treatment Plant #6 (GW)SE1<4<40none
2023-08-23Treatment Plant #7 (GW)SE1<4<40none
2023-08-23White River North Reservoir (MX)SE1<4<40PFPeA 3.9
2023-08-30Treatment Plant #8 (GW)SE1<4<40.002PFHxA 4, PFPeA 7.4
2023-11-07White River North Reservoir (MX)SE2<4<40PFPeA 4.5
2023-11-08Treatment Plant #1 (SW)SE2<4<40PFHxA 5, PFPeA 6.2
2023-11-08Treatment Plant #2 (SW)SE2<4<40PFHxA 3.2
2023-11-08Treatment Plant #3 (SW)SE2<4<40.002PFHxA 5.1, PFPeA 7.6
2024-02-19Treatment Plant #1 (SW)SE3<4<40none
2024-02-19Treatment Plant #2 (SW)SE3<4<40none
2024-02-19Treatment Plant #3 (SW)SE3<4<40PFBA 5.7, PFHxA 4.7, PFPeA 6.1
2024-02-20Treatment Plant #7 (GW)SE2<4<40none
2024-02-21Treatment Plant #5 (GW)SE2<4<40none
2024-02-21Treatment Plant #9 (GW)SE2<4<40none
2024-02-21White River North Reservoir (MX)SE3<4<40none
2024-02-28Treatment Plant #6 (GW)SE2<4<40none
2024-05-02Treatment Plant #1 (SW)SE4<4<40PFHxA 3.6, PFPeA 3
2024-05-03Treatment Plant #2 (SW)SE4<4<40PFHxA 3.5, PFPeA 4.2
2024-05-03Treatment Plant #3 (SW)SE4<4<40none
2024-05-03White River North Reservoir (MX)SE4<4<40none
2024-07-12Treatment Plant #8 (GW)SE2<4<40.002PFPeA 5.3
2024-08-23Treatment Plant #8 (GW)SE2n/an/an/anone

“<4” = not detected at the reporting limit shown; “n/a” = not analyzed in that sample. Highlighted = at or above the 4 ppt MCL. HI computed per sample with non-detects as 0. Other detections lists every other quantified compound (lithium in µg/L).

All results by entry point

780 results. Each column is one sampling visit (date and UCMR 5 sample event). A number is a measured concentration; “< 4” = below the minimum reporting level shown; “–” = not analyzed in that visit. PFAS in ppt (ng/L); lithium in µg/L.

Treatment Plant #1 facility 07427 · sample point EP001 · surface water

CompoundMRL2023-08-23
SE1
2023-11-08
SE2
2024-02-19
SE3
2024-05-02
SE4
PFHxA3 ppt4.45< 33.6
PFPeA3 ppt5.26.2< 33
11Cl-PF3OUdS5 ppt< 5< 5< 5< 5
4:2 FTS3 ppt< 3< 3< 3< 3
6:2 FTS5 ppt< 5< 5< 5< 5
8:2 FTS5 ppt< 5< 5< 5< 5
9Cl-PF3ONS2 ppt< 2< 2< 2< 2
ADONA3 ppt< 3< 3< 3< 3
HFPO-DA5 ppt< 5< 5< 5< 5
NEtFOSAA5 ppt< 5< 5< 5< 5
NFDHA20 ppt< 20< 20< 20< 20
NMeFOSAA6 ppt< 6< 6< 6< 6
PFBA5 ppt< 5< 5< 5< 5
PFBS3 ppt< 3< 3< 3< 3
PFDA3 ppt< 3< 3< 3< 3
PFDoA3 ppt< 3< 3< 3< 3
PFEESA3 ppt< 3< 3< 3< 3
PFHpA3 ppt< 3< 3< 3< 3
PFHpS3 ppt< 3< 3< 3< 3
PFHxS3 ppt< 3< 3< 3< 3
PFMBA3 ppt< 3< 3< 3< 3
PFMPA4 ppt< 4< 4< 4< 4
PFNA4 ppt< 4< 4< 4< 4
PFOA4 ppt< 4< 4< 4< 4
PFOS4 ppt< 4< 4< 4< 4
PFPeS4 ppt< 4< 4< 4< 4
PFTA8 ppt< 8< 8< 8< 8
PFTrDA7 ppt< 7< 7< 7< 7
PFUnA2 ppt< 2< 2< 2< 2
lithium9 µg/L< 9< 9< 9< 9

Treatment Plant #2 facility 17702 · sample point EP002 · surface water

CompoundMRL2023-08-22
SE1
2023-11-08
SE2
2024-02-19
SE3
2024-05-03
SE4
PFHxA3 ppt< 33.2< 33.5
PFPeA3 ppt< 3< 3< 34.2
11Cl-PF3OUdS5 ppt< 5< 5< 5< 5
4:2 FTS3 ppt< 3< 3< 3< 3
6:2 FTS5 ppt< 5< 5< 5< 5
8:2 FTS5 ppt< 5< 5< 5< 5
9Cl-PF3ONS2 ppt< 2< 2< 2< 2
ADONA3 ppt< 3< 3< 3< 3
HFPO-DA5 ppt< 5< 5< 5< 5
NEtFOSAA5 ppt< 5< 5< 5< 5
NFDHA20 ppt< 20< 20< 20< 20
NMeFOSAA6 ppt< 6< 6< 6< 6
PFBA5 ppt< 5< 5< 5< 5
PFBS3 ppt< 3< 3< 3< 3
PFDA3 ppt< 3< 3< 3< 3
PFDoA3 ppt< 3< 3< 3< 3
PFEESA3 ppt< 3< 3< 3< 3
PFHpA3 ppt< 3< 3< 3< 3
PFHpS3 ppt< 3< 3< 3< 3
PFHxS3 ppt< 3< 3< 3< 3
PFMBA3 ppt< 3< 3< 3< 3
PFMPA4 ppt< 4< 4< 4< 4
PFNA4 ppt< 4< 4< 4< 4
PFOA4 ppt< 4< 4< 4< 4
PFOS4 ppt< 4< 4< 4< 4
PFPeS4 ppt< 4< 4< 4< 4
PFTA8 ppt< 8< 8< 8< 8
PFTrDA7 ppt< 7< 7< 7< 7
PFUnA2 ppt< 2< 2< 2< 2
lithium9 µg/L< 9< 9< 9< 9

Treatment Plant #3 facility 17703 · sample point EP003 · surface water

CompoundMRL2023-08-23
SE1
2023-11-08
SE2
2024-02-19
SE3
2024-05-03
SE4
PFBA5 ppt5< 55.7< 5
PFBS3 ppt< 33.1< 3< 3
PFHxA3 ppt4.95.14.7< 3
PFPeA3 ppt6.77.66.1< 3
11Cl-PF3OUdS5 ppt< 5< 5< 5< 5
4:2 FTS3 ppt< 3< 3< 3< 3
6:2 FTS5 ppt< 5< 5< 5< 5
8:2 FTS5 ppt< 5< 5< 5< 5
9Cl-PF3ONS2 ppt< 2< 2< 2< 2
ADONA3 ppt< 3< 3< 3< 3
HFPO-DA5 ppt< 5< 5< 5< 5
NEtFOSAA5 ppt< 5< 5< 5< 5
NFDHA20 ppt< 20< 20< 20< 20
NMeFOSAA6 ppt< 6< 6< 6< 6
PFDA3 ppt< 3< 3< 3< 3
PFDoA3 ppt< 3< 3< 3< 3
PFEESA3 ppt< 3< 3< 3< 3
PFHpA3 ppt< 3< 3< 3< 3
PFHpS3 ppt< 3< 3< 3< 3
PFHxS3 ppt< 3< 3< 3< 3
PFMBA3 ppt< 3< 3< 3< 3
PFMPA4 ppt< 4< 4< 4< 4
PFNA4 ppt< 4< 4< 4< 4
PFOA4 ppt< 4< 4< 4< 4
PFOS4 ppt< 4< 4< 4< 4
PFPeS4 ppt< 4< 4< 4< 4
PFTA8 ppt< 8< 8< 8< 8
PFTrDA7 ppt< 7< 7< 7< 7
PFUnA2 ppt< 2< 2< 2< 2
lithium9 µg/L< 9< 9< 9< 9

Treatment Plant #5 facility 17705 · sample point EP005 · groundwater

CompoundMRL2023-08-22
SE1
2024-02-21
SE2
11Cl-PF3OUdS5 ppt< 5< 5
4:2 FTS3 ppt< 3< 3
6:2 FTS5 ppt< 5< 5
8:2 FTS5 ppt< 5< 5
9Cl-PF3ONS2 ppt< 2< 2
ADONA3 ppt< 3< 3
HFPO-DA5 ppt< 5< 5
NEtFOSAA5 ppt< 5< 5
NFDHA20 ppt< 20< 20
NMeFOSAA6 ppt< 6< 6
PFBA5 ppt< 5< 5
PFBS3 ppt< 3< 3
PFDA3 ppt< 3< 3
PFDoA3 ppt< 3< 3
PFEESA3 ppt< 3< 3
PFHpA3 ppt< 3< 3
PFHpS3 ppt< 3< 3
PFHxA3 ppt< 3< 3
PFHxS3 ppt< 3< 3
PFMBA3 ppt< 3< 3
PFMPA4 ppt< 4< 4
PFNA4 ppt< 4< 4
PFOA4 ppt< 4< 4
PFOS4 ppt< 4< 4
PFPeA3 ppt< 3< 3
PFPeS4 ppt< 4< 4
PFTA8 ppt< 8< 8
PFTrDA7 ppt< 7< 7
PFUnA2 ppt< 2< 2
lithium9 µg/L< 9< 9

Treatment Plant #6 facility 17706 · sample point EP006 · groundwater

CompoundMRL2023-08-23
SE1
2024-02-28
SE2
11Cl-PF3OUdS5 ppt< 5< 5
4:2 FTS3 ppt< 3< 3
6:2 FTS5 ppt< 5< 5
8:2 FTS5 ppt< 5< 5
9Cl-PF3ONS2 ppt< 2< 2
ADONA3 ppt< 3< 3
HFPO-DA5 ppt< 5< 5
NEtFOSAA5 ppt< 5< 5
NFDHA20 ppt< 20< 20
NMeFOSAA6 ppt< 6< 6
PFBA5 ppt< 5< 5
PFBS3 ppt< 3< 3
PFDA3 ppt< 3< 3
PFDoA3 ppt< 3< 3
PFEESA3 ppt< 3< 3
PFHpA3 ppt< 3< 3
PFHpS3 ppt< 3< 3
PFHxA3 ppt< 3< 3
PFHxS3 ppt< 3< 3
PFMBA3 ppt< 3< 3
PFMPA4 ppt< 4< 4
PFNA4 ppt< 4< 4
PFOA4 ppt< 4< 4
PFOS4 ppt< 4< 4
PFPeA3 ppt< 3< 3
PFPeS4 ppt< 4< 4
PFTA8 ppt< 8< 8
PFTrDA7 ppt< 7< 7
PFUnA2 ppt< 2< 2
lithium9 µg/L< 9< 9

Treatment Plant #7 facility 17707 · sample point EP007 · groundwater

CompoundMRL2023-08-23
SE1
2024-02-20
SE2
11Cl-PF3OUdS5 ppt< 5< 5
4:2 FTS3 ppt< 3< 3
6:2 FTS5 ppt< 5< 5
8:2 FTS5 ppt< 5< 5
9Cl-PF3ONS2 ppt< 2< 2
ADONA3 ppt< 3< 3
HFPO-DA5 ppt< 5< 5
NEtFOSAA5 ppt< 5< 5
NFDHA20 ppt< 20< 20
NMeFOSAA6 ppt< 6< 6
PFBA5 ppt< 5< 5
PFBS3 ppt< 3< 3
PFDA3 ppt< 3< 3
PFDoA3 ppt< 3< 3
PFEESA3 ppt< 3< 3
PFHpA3 ppt< 3< 3
PFHpS3 ppt< 3< 3
PFHxA3 ppt< 3< 3
PFHxS3 ppt< 3< 3
PFMBA3 ppt< 3< 3
PFMPA4 ppt< 4< 4
PFNA4 ppt< 4< 4
PFOA4 ppt< 4< 4
PFOS4 ppt< 4< 4
PFPeA3 ppt< 3< 3
PFPeS4 ppt< 4< 4
PFTA8 ppt< 8< 8
PFTrDA7 ppt< 7< 7
PFUnA2 ppt< 2< 2
lithium9 µg/L< 9< 9

Treatment Plant #8 facility 17708 · sample point EP008 · groundwater

CompoundMRL2023-08-30
SE1
2024-07-12
SE2
2024-08-23
SE2
PFBS3 ppt43.8–
PFHxA3 ppt4< 3–
PFPeA3 ppt7.45.3–
11Cl-PF3OUdS5 ppt< 5< 5–
4:2 FTS3 ppt< 3< 3–
6:2 FTS5 ppt< 5< 5–
8:2 FTS5 ppt< 5< 5–
9Cl-PF3ONS2 ppt< 2< 2–
ADONA3 ppt< 3< 3–
HFPO-DA5 ppt< 5< 5–
NEtFOSAA5 ppt< 5–< 5
NFDHA20 ppt< 20< 20–
NMeFOSAA6 ppt< 6–< 6
PFBA5 ppt< 5< 5–
PFDA3 ppt< 3< 3–
PFDoA3 ppt< 3< 3–
PFEESA3 ppt< 3< 3–
PFHpA3 ppt< 3< 3–
PFHpS3 ppt< 3< 3–
PFHxS3 ppt< 3< 3–
PFMBA3 ppt< 3< 3–
PFMPA4 ppt< 4< 4–
PFNA4 ppt< 4< 4–
PFOA4 ppt< 4< 4–
PFOS4 ppt< 4< 4–
PFPeS4 ppt< 4< 4–
PFTA8 ppt< 8–< 8
PFTrDA7 ppt< 7–< 7
PFUnA2 ppt< 2< 2–
lithium9 µg/L< 9< 9–

Treatment Plant #9 facility 31958 · sample point EP009 · groundwater

CompoundMRL2023-08-22
SE1
2024-02-21
SE2
11Cl-PF3OUdS5 ppt< 5< 5
4:2 FTS3 ppt< 3< 3
6:2 FTS5 ppt< 5< 5
8:2 FTS5 ppt< 5< 5
9Cl-PF3ONS2 ppt< 2< 2
ADONA3 ppt< 3< 3
HFPO-DA5 ppt< 5< 5
NEtFOSAA5 ppt< 5< 5
NFDHA20 ppt< 20< 20
NMeFOSAA6 ppt< 6< 6
PFBA5 ppt< 5< 5
PFBS3 ppt< 3< 3
PFDA3 ppt< 3< 3
PFDoA3 ppt< 3< 3
PFEESA3 ppt< 3< 3
PFHpA3 ppt< 3< 3
PFHpS3 ppt< 3< 3
PFHxA3 ppt< 3< 3
PFHxS3 ppt< 3< 3
PFMBA3 ppt< 3< 3
PFMPA4 ppt< 4< 4
PFNA4 ppt< 4< 4
PFOA4 ppt< 4< 4
PFOS4 ppt< 4< 4
PFPeA3 ppt< 3< 3
PFPeS4 ppt< 4< 4
PFTA8 ppt< 8< 8
PFTrDA7 ppt< 7< 7
PFUnA2 ppt< 2< 2
lithium9 µg/L< 9< 9

White River North Reservoir facility 17704 · sample point EP004 · MX

CompoundMRL2023-08-23
SE1
2023-11-07
SE2
2024-02-21
SE3
2024-05-03
SE4
PFPeA3 ppt3.94.5< 3< 3
11Cl-PF3OUdS5 ppt< 5< 5< 5< 5
4:2 FTS3 ppt< 3< 3< 3< 3
6:2 FTS5 ppt< 5< 5< 5< 5
8:2 FTS5 ppt< 5< 5< 5< 5
9Cl-PF3ONS2 ppt< 2< 2< 2< 2
ADONA3 ppt< 3< 3< 3< 3
HFPO-DA5 ppt< 5< 5< 5< 5
NEtFOSAA5 ppt< 5< 5< 5< 5
NFDHA20 ppt< 20< 20< 20< 20
NMeFOSAA6 ppt< 6< 6< 6< 6
PFBA5 ppt< 5< 5< 5< 5
PFBS3 ppt< 3< 3< 3< 3
PFDA3 ppt< 3< 3< 3< 3
PFDoA3 ppt< 3< 3< 3< 3
PFEESA3 ppt< 3< 3< 3< 3
PFHpA3 ppt< 3< 3< 3< 3
PFHpS3 ppt< 3< 3< 3< 3
PFHxA3 ppt< 3< 3< 3< 3
PFHxS3 ppt< 3< 3< 3< 3
PFMBA3 ppt< 3< 3< 3< 3
PFMPA4 ppt< 4< 4< 4< 4
PFNA4 ppt< 4< 4< 4< 4
PFOA4 ppt< 4< 4< 4< 4
PFOS4 ppt< 4< 4< 4< 4
PFPeS4 ppt< 4< 4< 4< 4
PFTA8 ppt< 8< 8< 8< 8
PFTrDA7 ppt< 7< 7< 7< 7
PFUnA2 ppt< 2< 2< 2< 2
lithium9 µg/L< 9< 9< 9< 9

Statistics by compound

CompoundResultsDetectedHighest (date)Mean boundsKM medianP75P90P95
PFPeA2642%7.6
2023-11-08
2.31–4.04<MRL5.26.77.4
PFHxA2635%5.1
2023-11-08
1.48–3.44<MRL3.64.95
PFBS2612%4
2023-08-30
0.42–3.07<MRL<MRL3.13.8
PFBA268%5.7
2024-02-19
0.41–5.03<MRL<MRL<MRL5

Never detected (26): 11Cl-PF3OUdS, 4:2 FTS, 6:2 FTS, 8:2 FTS, 9Cl-PF3ONS, ADONA, HFPO-DA, NEtFOSAA, NFDHA, NMeFOSAA, PFDA, PFDoA, PFEESA, PFHpA, PFHpS, PFHxS, PFMBA, PFMPA, PFNA, PFOA, PFOS, PFPeS, PFTA, PFTrDA, PFUnA, lithium.

Left-censored Kaplan–Meier statistics (Helsel 2005; Helsel & Lee 2006, NADA for R). Units: ppt; lithium µg/L. Each compound has one reporting limit, so the Kaplan–Meier mean equals the upper mean bound (non-detects at the MRL); the lower bound sets non-detects to 0. “<MRL” = the percentile falls below the reporting limit and cannot be estimated. These describe this system's UCMR 5 samples, not population estimates.

Sources

  • EPA UCMR 5 occurrence data text files (UCMR5_All.txt; samples 2023-01-09 to 2026-01-13; data summary dated Jul 2026)
  • EPA SDWIS via ECHO SDWA downloads, quarter 2026Q3
  • EPA Public Water System Service Areas v3 (Mar 2026)
  • US Census Bureau cartographic boundary counties 1:500k, 2024
  • EPA/USGS NHDPlus V2 (medium resolution) flowlines, Strahler order 2+

Data build 04d76455c196 · 2026-10-18T04:06Z · UCMR 5 release Jul2026 · SDWIS 2026Q3. Data and methods.