Mountain Home Air Force Base

PFAS monitoring results for a public water system in Idaho

ID4200054UCMR 5EPA monitoring data
<MRLHighest PFOA result, ppt
<MRLHighest PFOS result, ppt
1.002Highest Hazard Index
180Results
PWSID
ID4200054
State
Idaho
System type
community water system (CWS)
Population served
7,500
City
Mountain Home Afb
Counties
Elmore County
Primary source water
groundwater
UCMR 5 sampling
2023-04-18 to 2023-12-06 · 3 entry point(s) · water types: GW
Service-area boundary
EPA-modeled (Random Forest) — approximate: estimated by EPA with a statistical model, not a surveyed service area

Hazard Index 1–3 × its limit highest single result
Hazard Index below its limit worst entry-point average

These are monitoring results collected under EPA's Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) at entry points, where treated water enters the distribution system; they are not tap-water samples. They are not compliance determinations: compliance with EPA's 2024 PFAS limits is judged on running annual averages of compliance monitoring, required from 2029, so a single UCMR 5 result at or above a limit is not a violation. “< MRL” means the compound was not quantified at EPA's minimum reporting level; it does not mean zero.

Compared with EPA's 2024 values

Highest single resultWorst entry-point average*Limit
PFOA (ppt)<MRL04
PFOS (ppt)<MRL04
Hazard Index1.0020.8061.0†

“<MRL” = every result for the compound was below its reporting limit. * Mean of all samples at each entry point with non-detects = 0 (EPA compliance convention; the Hazard Index also uses non-detects = 0); a screening comparison, not a formal running annual average. † Rescission proposed May 2026. PFOA/PFOS MCL 4 ppt (2024 NPDWR, in effect). PFHxS, PFNA, HFPO-DA (10 ppt each) and the Hazard Index (1.0) are 2024 NPDWR values; EPA proposed rescinding them on 18 May 2026 (comment period closed 20 Jul 2026).

No Idaho PFAS drinking-water standard in effect or proposed as of 2026-10-17: No Idaho-specific PFAS drinking-water standard; Idaho adopts only final national primary drinking water standards (DEQ PFAS and Idaho Drinking Water page, updated 2026-09-29).

Sampling history

Sampled 2023-04-18 to 2023-12-06 · 3 entry point(s) · water types: GW · 9 sampling visits. PFAS in ppt (ng/L).

DateEntry pointEventPFOAPFOSHIOther detections
2023-04-18MOUNTAIN HOME AIR FORCE BASE (GW)SE1<4<40.61PFHxA 6.3, PFPeA 4.2
2023-04-18MOUNTAIN HOME AIR FORCE BASE (GW)SE1<4<40.62PFHxA 6.1, PFPeA 4
2023-04-18MOUNTAIN HOME AIR FORCE BASE (GW)SE1<4<40none
2023-10-25MOUNTAIN HOME AIR FORCE BASE (GW)SE2<4<41.002PFHxA 13, PFPeA 6.7
2023-10-25MOUNTAIN HOME AIR FORCE BASE (GW)SE2<4<40none
2023-10-25MOUNTAIN HOME AIR FORCE BASE (GW)SE2<4<40none
2023-12-06MOUNTAIN HOME AIR FORCE BASE (GW)SE2n/an/an/anone
2023-12-06MOUNTAIN HOME AIR FORCE BASE (GW)SE2n/an/an/anone
2023-12-06MOUNTAIN HOME AIR FORCE BASE (GW)SE2n/an/an/anone

“<4” = not detected at the reporting limit shown; “n/a” = not analyzed in that sample. Highlighted = at or above the 4 ppt MCL. HI computed per sample with non-detects as 0. Other detections lists every other quantified compound (lithium in µg/L).

All results by entry point

180 results. Each column is one sampling visit (date and UCMR 5 sample event). A number is a measured concentration; “< 4” = below the minimum reporting level shown; “–” = not analyzed in that visit. PFAS in ppt (ng/L); lithium in µg/L.

MOUNTAIN HOME AIR FORCE BASE facility A0003864 · sample point WELL2 · groundwater

CompoundMRL2023-04-18
SE1
2023-10-25
SE2
2023-12-06
SE2
PFBS3 ppt< 34.8–
PFHxA3 ppt6.313–
PFHxS3 ppt6.110–
PFPeA3 ppt4.26.7–
11Cl-PF3OUdS5 ppt< 5< 5–
4:2 FTS3 ppt< 3< 3–
6:2 FTS5 ppt< 5< 5–
8:2 FTS5 ppt< 5< 5–
9Cl-PF3ONS2 ppt< 2< 2–
ADONA3 ppt< 3< 3–
HFPO-DA5 ppt< 5< 5–
NEtFOSAA5 ppt< 5–< 5
NFDHA20 ppt< 20< 20–
NMeFOSAA6 ppt< 6–< 6
PFBA5 ppt< 5< 5–
PFDA3 ppt< 3< 3–
PFDoA3 ppt< 3< 3–
PFEESA3 ppt< 3< 3–
PFHpA3 ppt< 3< 3–
PFHpS3 ppt< 3< 3–
PFMBA3 ppt< 3< 3–
PFMPA4 ppt< 4< 4–
PFNA4 ppt< 4< 4–
PFOA4 ppt< 4< 4–
PFOS4 ppt< 4< 4–
PFPeS4 ppt< 4< 4–
PFTA8 ppt< 8–< 8
PFTrDA7 ppt< 7–< 7
PFUnA2 ppt< 2< 2–
lithium9 µg/L< 9< 9–

MOUNTAIN HOME AIR FORCE BASE facility D0077509 · sample point WELL14 · groundwater

CompoundMRL2023-04-18
SE1
2023-10-25
SE2
2023-12-06
SE2
PFHxA3 ppt6.1< 3–
PFHxS3 ppt6.2< 3–
PFPeA3 ppt4< 3–
11Cl-PF3OUdS5 ppt< 5< 5–
4:2 FTS3 ppt< 3< 3–
6:2 FTS5 ppt< 5< 5–
8:2 FTS5 ppt< 5< 5–
9Cl-PF3ONS2 ppt< 2< 2–
ADONA3 ppt< 3< 3–
HFPO-DA5 ppt< 5< 5–
NEtFOSAA5 ppt< 5–< 5
NFDHA20 ppt< 20< 20–
NMeFOSAA6 ppt< 6–< 6
PFBA5 ppt< 5< 5–
PFBS3 ppt< 3< 3–
PFDA3 ppt< 3< 3–
PFDoA3 ppt< 3< 3–
PFEESA3 ppt< 3< 3–
PFHpA3 ppt< 3< 3–
PFHpS3 ppt< 3< 3–
PFMBA3 ppt< 3< 3–
PFMPA4 ppt< 4< 4–
PFNA4 ppt< 4< 4–
PFOA4 ppt< 4< 4–
PFOS4 ppt< 4< 4–
PFPeS4 ppt< 4< 4–
PFTA8 ppt< 8–< 8
PFTrDA7 ppt< 7–< 7
PFUnA2 ppt< 2< 2–
lithium9 µg/L< 9< 9–

MOUNTAIN HOME AIR FORCE BASE facility E0008877 · sample point WELL13 · groundwater

CompoundMRL2023-04-18
SE1
2023-10-25
SE2
2023-12-06
SE2
11Cl-PF3OUdS5 ppt< 5< 5–
4:2 FTS3 ppt< 3< 3–
6:2 FTS5 ppt< 5< 5–
8:2 FTS5 ppt< 5< 5–
9Cl-PF3ONS2 ppt< 2< 2–
ADONA3 ppt< 3< 3–
HFPO-DA5 ppt< 5< 5–
NEtFOSAA5 ppt< 5–< 5
NFDHA20 ppt< 20< 20–
NMeFOSAA6 ppt< 6–< 6
PFBA5 ppt< 5< 5–
PFBS3 ppt< 3< 3–
PFDA3 ppt< 3< 3–
PFDoA3 ppt< 3< 3–
PFEESA3 ppt< 3< 3–
PFHpA3 ppt< 3< 3–
PFHpS3 ppt< 3< 3–
PFHxA3 ppt< 3< 3–
PFHxS3 ppt< 3< 3–
PFMBA3 ppt< 3< 3–
PFMPA4 ppt< 4< 4–
PFNA4 ppt< 4< 4–
PFOA4 ppt< 4< 4–
PFOS4 ppt< 4< 4–
PFPeA3 ppt< 3< 3–
PFPeS4 ppt< 4< 4–
PFTA8 ppt< 8–< 8
PFTrDA7 ppt< 7–< 7
PFUnA2 ppt< 2< 2–
lithium9 µg/L< 9< 9–

Statistics by compound

CompoundResultsDetectedHighest (date)Mean boundsKM medianP75P90P95
PFHxA650%13
2023-10-25
4.23–5.73<MRL6.31313
PFHxS650%10
2023-10-25
3.72–5.22<MRL6.21010
PFPeA650%6.7
2023-10-25
2.48–3.98<MRL4.26.76.7
PFBS617%4.8
2023-10-25
0.8–3.3<MRL<MRL4.84.8

Never detected (26): 11Cl-PF3OUdS, 4:2 FTS, 6:2 FTS, 8:2 FTS, 9Cl-PF3ONS, ADONA, HFPO-DA, NEtFOSAA, NFDHA, NMeFOSAA, PFBA, PFDA, PFDoA, PFEESA, PFHpA, PFHpS, PFMBA, PFMPA, PFNA, PFOA, PFOS, PFPeS, PFTA, PFTrDA, PFUnA, lithium.

Left-censored Kaplan–Meier statistics (Helsel 2005; Helsel & Lee 2006, NADA for R). Units: ppt; lithium µg/L. Each compound has one reporting limit, so the Kaplan–Meier mean equals the upper mean bound (non-detects at the MRL); the lower bound sets non-detects to 0. “<MRL” = the percentile falls below the reporting limit and cannot be estimated. These describe this system's UCMR 5 samples, not population estimates.

Sources

  • EPA UCMR 5 occurrence data text files (UCMR5_All.txt; samples 2023-01-17 to 2026-03-03; data summary dated Jul 2026)
  • EPA SDWIS via ECHO SDWA downloads, quarter 2026Q3
  • EPA Public Water System Service Areas v3 (Mar 2026)
  • US Census Bureau cartographic boundary counties 1:500k, 2024
  • EPA/USGS NHDPlus V2 (medium resolution) flowlines, Strahler order 2+

Data build cfc4eb4a204c · 2026-10-18T04:05Z · UCMR 5 release Jul2026 · SDWIS 2026Q3. Data and methods.