North Port Utilities

PFAS monitoring results for a public water system in Florida

FL6580651UCMR 5EPA monitoring data
5.5Highest PFOA result, ppt
4.1Highest PFOS result, ppt
0.003Highest Hazard Index
395Results
PWSID
FL6580651
State
Florida
System type
community water system (CWS)
Population served
61,163
City
North Port
Counties
Sarasota County
Primary source water
surface water
UCMR 5 sampling
2024-01-23 to 2024-12-17 · 4 entry point(s) · water types: GW;MX;SW
Service-area boundary
authoritative

PFOA 1–3 × its limit highest single result
PFOA below its limit worst entry-point average

These are monitoring results collected under EPA's Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) at entry points, where treated water enters the distribution system; they are not tap-water samples. They are not compliance determinations: compliance with EPA's 2024 PFAS limits is judged on running annual averages of compliance monitoring, required from 2029, so a single UCMR 5 result at or above a limit is not a violation. “< MRL” means the compound was not quantified at EPA's minimum reporting level; it does not mean zero.

Water purchased from

Seller results are the seller's own entry-point samples, not measurements of this system's water. This system's own samples (below) may reflect purchased water, its own sources, or both.

Compared with EPA's 2024 values

Highest single resultWorst entry-point average*Limit
PFOA (ppt)5.53.94
PFOS (ppt)4.11.024
Hazard Index0.0030.0031.0†

“<MRL” = every result for the compound was below its reporting limit. * Mean of all samples at each entry point with non-detects = 0 (EPA compliance convention; the Hazard Index also uses non-detects = 0); a screening comparison, not a formal running annual average. † Rescission proposed May 2026. PFOA/PFOS MCL 4 ppt (2024 NPDWR, in effect). PFHxS, PFNA, HFPO-DA (10 ppt each) and the Hazard Index (1.0) are 2024 NPDWR values; EPA proposed rescinding them on 18 May 2026 (comment period closed 20 Jul 2026).

No Florida PFAS drinking-water standard in effect or proposed as of 2026-10-17: No state PFAS drinking-water MCL. Ch. 2022-203 Laws of Fla. (s. 376.91) concerns contaminated-site cleanup target levels, not drinking water.

Sampling history

Sampled 2024-01-23 to 2024-12-17 · 4 entry point(s) · water types: GW;MX;SW · 15 sampling visits. PFAS in ppt (ng/L).

DateEntry pointEventPFOAPFOSHIOther detections
2024-01-23Myakkahatchee Creek Water Treatment Plant (MX)SE1<4<40none
2024-01-23Peace River Interconnect (Price) (SW)SE15<40.003PFBA 6, PFHxA 3.6, PFPeA 4.5
2024-01-23Sarasota Interconnect (MX)SE1<4<40none
2024-01-23Wellen Park Water Treatment Plant (GW)SE1<4<40none
2024-04-09Myakkahatchee Creek Water Treatment Plant (MX)SE2<4<40.002PFBA 6, PFPeA 3.7
2024-04-09Peace River Interconnect (Price) (SW)SE25.54.10.003PFBA 7.7, PFHxA 3.2, PFPeA 5.4
2024-04-09Sarasota Interconnect (MX)SE2<4<40none
2024-07-10Myakkahatchee Creek Water Treatment Plant (MX)SE3n/an/an/anone
2024-07-10Peace River Interconnect (Price) (SW)SE3<4<40.003PFBA 6, PFHxA 3, PFPeA 4.6
2024-07-10Sarasota Interconnect (MX)SE3<4<40none
2024-07-10Wellen Park Water Treatment Plant (GW)SE2<4<40none
2024-10-15Myakkahatchee Creek Water Treatment Plant (MX)SE4<4<40none
2024-10-15Peace River Interconnect (Price) (SW)SE4n/an/an/anone
2024-10-15Sarasota Interconnect (MX)SE4<4<40none
2024-12-17Peace River Interconnect (Price) (SW)SE45.1<40.003PFBA 7.4, PFHxA 4.1, PFPeA 6.4

“<4” = not detected at the reporting limit shown; “n/a” = not analyzed in that sample. Highlighted = at or above the 4 ppt MCL. HI computed per sample with non-detects as 0. Other detections lists every other quantified compound (lithium in µg/L).

All results by entry point

395 results. Each column is one sampling visit (date and UCMR 5 sample event). A number is a measured concentration; “< 4” = below the minimum reporting level shown; “–” = not analyzed in that visit. PFAS in ppt (ng/L); lithium in µg/L.

Myakkahatchee Creek Water Treatment Plant facility 1 · sample point POE · MX

CompoundMRL2024-01-23
SE1
2024-04-09
SE2
2024-07-10
SE3
2024-10-15
SE4
PFBA5 ppt< 56–< 5
PFBS3 ppt< 34.2–< 3
PFPeA3 ppt< 33.7–< 3
11Cl-PF3OUdS5 ppt< 5< 5–< 5
4:2 FTS3 ppt< 3< 3–< 3
6:2 FTS5 ppt< 5< 5–< 5
8:2 FTS5 ppt< 5< 5–< 5
9Cl-PF3ONS2 ppt< 2< 2–< 2
ADONA3 ppt< 3< 3–< 3
HFPO-DA5 ppt< 5< 5–< 5
NEtFOSAA5 ppt< 5< 5< 5< 5
NFDHA20 ppt< 20< 20–< 20
NMeFOSAA6 ppt< 6< 6< 6< 6
PFDA3 ppt< 3< 3–< 3
PFDoA3 ppt< 3< 3–< 3
PFEESA3 ppt< 3< 3–< 3
PFHpA3 ppt< 3< 3–< 3
PFHpS3 ppt< 3< 3–< 3
PFHxA3 ppt< 3< 3–< 3
PFHxS3 ppt< 3< 3–< 3
PFMBA3 ppt< 3< 3–< 3
PFMPA4 ppt< 4< 4–< 4
PFNA4 ppt< 4< 4–< 4
PFOA4 ppt< 4< 4–< 4
PFOS4 ppt< 4< 4–< 4
PFPeS4 ppt< 4< 4–< 4
PFTA8 ppt< 8< 8< 8< 8
PFTrDA7 ppt< 7< 7< 7< 7
PFUnA2 ppt< 2< 2–< 2
lithium9 µg/L< 9< 9< 9< 9

Peace River Interconnect (Price) facility 4 · sample point PRINTER · surface water

CompoundMRL2024-01-23
SE1
2024-04-09
SE2
2024-07-10
SE3
2024-10-15
SE4
2024-12-17
SE4
PFBA5 ppt67.76–7.4
PFBS3 ppt66.75.5–6.2
PFHxA3 ppt3.63.23–4.1
PFOA4 ppt55.5< 4–5.1
PFOS4 ppt< 44.1< 4–< 4
PFPeA3 ppt4.55.44.6–6.4
11Cl-PF3OUdS5 ppt< 5< 5< 5–< 5
4:2 FTS3 ppt< 3< 3< 3–< 3
6:2 FTS5 ppt< 5< 5< 5–< 5
8:2 FTS5 ppt< 5< 5< 5–< 5
9Cl-PF3ONS2 ppt< 2< 2< 2–< 2
ADONA3 ppt< 3< 3< 3–< 3
HFPO-DA5 ppt< 5< 5< 5–< 5
NEtFOSAA5 ppt< 5< 5< 5< 5–
NFDHA20 ppt< 20< 20< 20–< 20
NMeFOSAA6 ppt< 6< 6< 6< 6–
PFDA3 ppt< 3< 3< 3–< 3
PFDoA3 ppt< 3< 3< 3–< 3
PFEESA3 ppt< 3< 3< 3–< 3
PFHpA3 ppt< 3< 3< 3–< 3
PFHpS3 ppt< 3< 3< 3–< 3
PFHxS3 ppt< 3< 3< 3–< 3
PFMBA3 ppt< 3< 3< 3–< 3
PFMPA4 ppt< 4< 4< 4–< 4
PFNA4 ppt< 4< 4< 4–< 4
PFPeS4 ppt< 4< 4< 4–< 4
PFTA8 ppt< 8< 8< 8< 8–
PFTrDA7 ppt< 7< 7< 7< 7–
PFUnA2 ppt< 2< 2< 2–< 2
lithium9 µg/L< 9< 9< 9< 9–

Sarasota Interconnect facility 3 · sample point SARAINTER · MX

CompoundMRL2024-01-23
SE1
2024-04-09
SE2
2024-07-10
SE3
2024-10-15
SE4
11Cl-PF3OUdS5 ppt< 5< 5< 5< 5
4:2 FTS3 ppt< 3< 3< 3< 3
6:2 FTS5 ppt< 5< 5< 5< 5
8:2 FTS5 ppt< 5< 5< 5< 5
9Cl-PF3ONS2 ppt< 2< 2< 2< 2
ADONA3 ppt< 3< 3< 3< 3
HFPO-DA5 ppt< 5< 5< 5< 5
NEtFOSAA5 ppt< 5< 5< 5< 5
NFDHA20 ppt< 20< 20< 20< 20
NMeFOSAA6 ppt< 6< 6< 6< 6
PFBA5 ppt< 5< 5< 5< 5
PFBS3 ppt< 3< 3< 3< 3
PFDA3 ppt< 3< 3< 3< 3
PFDoA3 ppt< 3< 3< 3< 3
PFEESA3 ppt< 3< 3< 3< 3
PFHpA3 ppt< 3< 3< 3< 3
PFHpS3 ppt< 3< 3< 3< 3
PFHxA3 ppt< 3< 3< 3< 3
PFHxS3 ppt< 3< 3< 3< 3
PFMBA3 ppt< 3< 3< 3< 3
PFMPA4 ppt< 4< 4< 4< 4
PFNA4 ppt< 4< 4< 4< 4
PFOA4 ppt< 4< 4< 4< 4
PFOS4 ppt< 4< 4< 4< 4
PFPeA3 ppt< 3< 3< 3< 3
PFPeS4 ppt< 4< 4< 4< 4
PFTA8 ppt< 8< 8< 8< 8
PFTrDA7 ppt< 7< 7< 7< 7
PFUnA2 ppt< 2< 2< 2< 2
lithium9 µg/L< 9< 9< 9< 9

Wellen Park Water Treatment Plant facility 2 · sample point POE · groundwater

CompoundMRL2024-01-23
SE1
2024-07-10
SE2
11Cl-PF3OUdS5 ppt< 5< 5
4:2 FTS3 ppt< 3< 3
6:2 FTS5 ppt< 5< 5
8:2 FTS5 ppt< 5< 5
9Cl-PF3ONS2 ppt< 2< 2
ADONA3 ppt< 3< 3
HFPO-DA5 ppt< 5< 5
NEtFOSAA5 ppt< 5< 5
NFDHA20 ppt< 20< 20
NMeFOSAA6 ppt< 6< 6
PFBA5 ppt< 5< 5
PFBS3 ppt< 3< 3
PFDA3 ppt< 3< 3
PFDoA3 ppt< 3< 3
PFEESA3 ppt< 3< 3
PFHpA3 ppt< 3< 3
PFHpS3 ppt< 3< 3
PFHxA3 ppt< 3< 3
PFHxS3 ppt< 3< 3
PFMBA3 ppt< 3< 3
PFMPA4 ppt< 4< 4
PFNA4 ppt< 4< 4
PFOA4 ppt< 4< 4
PFOS4 ppt< 4< 4
PFPeA3 ppt< 3< 3
PFPeS4 ppt< 4< 4
PFTA8 ppt< 8< 8
PFTrDA7 ppt< 7< 7
PFUnA2 ppt< 2< 2
lithium9 µg/L< 9< 9

Statistics by compound

CompoundResultsDetectedHighest (date)Mean boundsKM medianP75P90P95
PFBA1338%7.7
2024-04-09
2.55–5.62<MRL67.47.7
PFBS1338%6.7
2024-04-09
2.2–4.05<MRL5.56.26.7
PFPeA1338%6.4
2024-12-17
1.89–3.74<MRL4.55.46.4
PFHxA1331%4.1
2024-12-17
1.07–3.15<MRL33.64.1
PFOA1323%5.5
2024-04-09
1.2–4.28<MRL<MRL5.15.5
PFOS138%4.1
2024-04-09
0.32–4.01<MRL<MRL<MRL4.1

Never detected (24): 11Cl-PF3OUdS, 4:2 FTS, 6:2 FTS, 8:2 FTS, 9Cl-PF3ONS, ADONA, HFPO-DA, NEtFOSAA, NFDHA, NMeFOSAA, PFDA, PFDoA, PFEESA, PFHpA, PFHpS, PFHxS, PFMBA, PFMPA, PFNA, PFPeS, PFTA, PFTrDA, PFUnA, lithium.

Left-censored Kaplan–Meier statistics (Helsel 2005; Helsel & Lee 2006, NADA for R). Units: ppt; lithium µg/L. Each compound has one reporting limit, so the Kaplan–Meier mean equals the upper mean bound (non-detects at the MRL); the lower bound sets non-detects to 0. “<MRL” = the percentile falls below the reporting limit and cannot be estimated. These describe this system's UCMR 5 samples, not population estimates.

Sources

  • EPA UCMR 5 occurrence data text files (UCMR5_All.txt; samples 2023-01-03 to 2026-06-09; data summary dated Jul 2026)
  • EPA SDWIS via ECHO SDWA downloads, quarter 2026Q3
  • EPA Public Water System Service Areas v3 (Mar 2026)
  • US Census Bureau cartographic boundary counties 1:500k, 2024
  • EPA/USGS NHDPlus V2 (medium resolution) flowlines, Strahler order 2+

Data build 77d99d3b80c8 · 2026-10-18T04:10Z · UCMR 5 release Jul2026 · SDWIS 2026Q3. Data and methods.