- PWSID
- FL4130970
- State
- Florida
- System type
- community water system (CWS)
- Population served
- 8,317
- City
- North Bay Village
- Counties
- Miami-Dade County
- Primary source water
- groundwater (purchased)
- UCMR 5 sampling
- 2023-05-08 to 2023-12-06 · 1 entry point(s) · water types: GW
- Service-area boundary
- authoritative
PFOS ≥ 3 × its limit highest single result
PFOS ≥ 3 × its limit worst entry-point average
Open on the Florida map · All Florida systems · All results
These are monitoring results collected under EPA's Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) at entry points, where treated water enters the distribution system; they are not tap-water samples. They are not compliance determinations: compliance with EPA's 2024 PFAS limits is judged on running annual averages of compliance monitoring, required from 2029, so a single UCMR 5 result at or above a limit is not a violation. “< MRL” means the compound was not quantified at EPA's minimum reporting level; it does not mean zero.
Water purchased from
- Mdwasa - Main System (FL4130871)
Seller's highest results: PFOA 14 ppt · PFOS 33 ppt · HI 1.592 · detected: 6:2 FTS;8:2 FTS;PFBA;PFBS;PFHpA;PFHxA;PFHxS;PFNA;PFOA;PFOS;PFPeA
Seller results are the seller's own entry-point samples, not measurements of this system's water. This system's own samples (below) may reflect purchased water, its own sources, or both.
Compared with EPA's 2024 values
| Highest single result | Worst entry-point average* | Limit | |
|---|---|---|---|
| PFOA (ppt) | 14.2 | 9.9 | 4 |
| PFOS (ppt) | 43.3 | 30.45 | 4 |
| Hazard Index | 1.473 | 0.953 | 1.0† |
“<MRL” = every result for the compound was below its reporting limit. * Mean of all samples at each entry point with non-detects = 0 (EPA compliance convention; the Hazard Index also uses non-detects = 0); a screening comparison, not a formal running annual average. † Rescission proposed May 2026. PFOA/PFOS MCL 4 ppt (2024 NPDWR, in effect). PFHxS, PFNA, HFPO-DA (10 ppt each) and the Hazard Index (1.0) are 2024 NPDWR values; EPA proposed rescinding them on 18 May 2026 (comment period closed 20 Jul 2026).
No Florida PFAS drinking-water standard in effect or proposed as of 2026-10-17: No state PFAS drinking-water MCL. Ch. 2022-203 Laws of Fla. (s. 376.91) concerns contaminated-site cleanup target levels, not drinking water.
Sampling history
Sampled 2023-05-08 to 2023-12-06 · 1 entry point(s) · water types: GW · 3 sampling visits. PFAS in ppt (ng/L).
| Date | Entry point | Event | PFOA | PFOS | HI | Other detections |
|---|---|---|---|---|---|---|
| 2023-05-08 | Entry Point Facility (GW) | SE1 | 5.6 | 17.6 | 0.432 | 6:2 FTS 56.8, PFBA 11.7, PFHpA 7.3, PFHxA 19.7, PFPeA 18.5 |
| 2023-11-13 | Entry Point Facility (GW) | SE2 | n/a | n/a | n/a | none |
| 2023-12-06 | Entry Point Facility (GW) | SE2 | 14.2 | 43.3 | 1.473 | 6:2 FTS 135.7, 8:2 FTS 10.7, PFBA 19.9, PFHpA 20.8, PFHxA 52.9, PFPeA 47.1 |
“<4” = not detected at the reporting limit shown; “n/a” = not analyzed in that sample. Highlighted = at or above the 4 ppt MCL. HI computed per sample with non-detects as 0. Other detections lists every other quantified compound (lithium in µg/L).
All results by entry point
60 results. Each column is one sampling visit (date and UCMR 5 sample event). A number is a measured concentration; “< 4” = below the minimum reporting level shown; “–” = not analyzed in that visit. PFAS in ppt (ng/L); lithium in µg/L.
Entry Point Facility facility 1 · sample point DIS · groundwater
| Compound | MRL | 2023-05-08 SE1 | 2023-11-13 SE2 | 2023-12-06 SE2 |
|---|---|---|---|---|
| 6:2 FTS | 5 ppt | 56.8 | – | 135.7 |
| 8:2 FTS | 5 ppt | < 5 | – | 10.7 |
| PFBA | 5 ppt | 11.7 | – | 19.9 |
| PFBS | 3 ppt | 3.4 | – | 6.5 |
| PFHpA | 3 ppt | 7.3 | – | 20.8 |
| PFHxA | 3 ppt | 19.7 | – | 52.9 |
| PFHxS | 3 ppt | 4.3 | – | 9.1 |
| PFNA | 4 ppt | < 4 | – | 5.6 |
| PFOA | 4 ppt | 5.6 | – | 14.2 |
| PFOS | 4 ppt | 17.6 | – | 43.3 |
| PFPeA | 3 ppt | 18.5 | – | 47.1 |
| 11Cl-PF3OUdS | 5 ppt | < 5 | – | < 5 |
| 4:2 FTS | 3 ppt | < 3 | – | < 3 |
| 9Cl-PF3ONS | 2 ppt | < 2 | – | < 2 |
| ADONA | 3 ppt | < 3 | – | < 3 |
| HFPO-DA | 5 ppt | < 5 | – | < 5 |
| NEtFOSAA | 5 ppt | < 5 | – | < 5 |
| NFDHA | 20 ppt | < 20 | – | < 20 |
| NMeFOSAA | 6 ppt | < 6 | – | < 6 |
| PFDA | 3 ppt | < 3 | – | < 3 |
| PFDoA | 3 ppt | < 3 | – | < 3 |
| PFEESA | 3 ppt | < 3 | – | < 3 |
| PFHpS | 3 ppt | < 3 | – | < 3 |
| PFMBA | 3 ppt | < 3 | – | < 3 |
| PFMPA | 4 ppt | < 4 | – | < 4 |
| PFPeS | 4 ppt | < 4 | – | < 4 |
| PFTA | 8 ppt | < 8 | – | < 8 |
| PFTrDA | 7 ppt | < 7 | – | < 7 |
| PFUnA | 2 ppt | < 2 | – | < 2 |
| lithium | 9 µg/L | < 9 | < 9 | – |
Statistics by compound
| Compound | Results | Detected | Highest (date) | Mean bounds | KM median | P75 | P90 | P95 |
|---|---|---|---|---|---|---|---|---|
| 6:2 FTS | 2 | 100% | 135.7 2023-12-06 | 96.25–96.25 | fewer than 4 results: raw values only | |||
| PFBA | 2 | 100% | 19.9 2023-12-06 | 15.8–15.8 | fewer than 4 results: raw values only | |||
| PFBS | 2 | 100% | 6.5 2023-12-06 | 4.95–4.95 | fewer than 4 results: raw values only | |||
| PFHpA | 2 | 100% | 20.8 2023-12-06 | 14.05–14.05 | fewer than 4 results: raw values only | |||
| PFHxA | 2 | 100% | 52.9 2023-12-06 | 36.3–36.3 | fewer than 4 results: raw values only | |||
| PFHxS | 2 | 100% | 9.1 2023-12-06 | 6.7–6.7 | fewer than 4 results: raw values only | |||
| PFOA | 2 | 100% | 14.2 2023-12-06 | 9.9–9.9 | fewer than 4 results: raw values only | |||
| PFOS | 2 | 100% | 43.3 2023-12-06 | 30.45–30.45 | fewer than 4 results: raw values only | |||
| PFPeA | 2 | 100% | 47.1 2023-12-06 | 32.8–32.8 | fewer than 4 results: raw values only | |||
| 8:2 FTS | 2 | 50% | 10.7 2023-12-06 | 5.35–7.85 | fewer than 4 results: raw values only | |||
| PFNA | 2 | 50% | 5.6 2023-12-06 | 2.8–4.8 | fewer than 4 results: raw values only | |||
Never detected (19): 11Cl-PF3OUdS, 4:2 FTS, 9Cl-PF3ONS, ADONA, HFPO-DA, NEtFOSAA, NFDHA, NMeFOSAA, PFDA, PFDoA, PFEESA, PFHpS, PFMBA, PFMPA, PFPeS, PFTA, PFTrDA, PFUnA, lithium.
Left-censored Kaplan–Meier statistics (Helsel 2005; Helsel & Lee 2006, NADA for R). Units: ppt; lithium µg/L. Each compound has one reporting limit, so the Kaplan–Meier mean equals the upper mean bound (non-detects at the MRL); the lower bound sets non-detects to 0. “<MRL” = the percentile falls below the reporting limit and cannot be estimated. These describe this system's UCMR 5 samples, not population estimates.
Sources
- EPA UCMR 5 occurrence data text files (UCMR5_All.txt; samples 2023-01-03 to 2026-06-09; data summary dated Jul 2026)
- EPA SDWIS via ECHO SDWA downloads, quarter 2026Q3
- EPA Public Water System Service Areas v3 (Mar 2026)
- US Census Bureau cartographic boundary counties 1:500k, 2024
- EPA/USGS NHDPlus V2 (medium resolution) flowlines, Strahler order 2+
Data build 77d99d3b80c8 · 2026-10-18T04:10Z · UCMR 5 release Jul2026 · SDWIS 2026Q3. Data and methods.