- PWSID
- FL3350977
- State
- Florida
- System type
- community water system (CWS)
- Population served
- 7,090
- City
- Lady Lake
- Counties
- Lake County
- Primary source water
- groundwater
- UCMR 5 sampling
- 2025-01-06 to 2025-07-08 · 3 entry point(s) · water types: GW
- Service-area boundary
- authoritative
PFOS ≥ 3 × its limit highest single result
PFOS ≥ 3 × its limit worst entry-point average
Open on the Florida map · All Florida systems · All results
These are monitoring results collected under EPA's Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) at entry points, where treated water enters the distribution system; they are not tap-water samples. They are not compliance determinations: compliance with EPA's 2024 PFAS limits is judged on running annual averages of compliance monitoring, required from 2029, so a single UCMR 5 result at or above a limit is not a violation. “< MRL” means the compound was not quantified at EPA's minimum reporting level; it does not mean zero.
Compared with EPA's 2024 values
| Highest single result | Worst entry-point average* | Limit | |
|---|---|---|---|
| PFOA (ppt) | 4.8 | 2.4 | 4 |
| PFOS (ppt) | 32.4 | 16.2 | 4 |
| Hazard Index | 2.82 | 1.567 | 1.0† |
“<MRL” = every result for the compound was below its reporting limit. * Mean of all samples at each entry point with non-detects = 0 (EPA compliance convention; the Hazard Index also uses non-detects = 0); a screening comparison, not a formal running annual average. † Rescission proposed May 2026. PFOA/PFOS MCL 4 ppt (2024 NPDWR, in effect). PFHxS, PFNA, HFPO-DA (10 ppt each) and the Hazard Index (1.0) are 2024 NPDWR values; EPA proposed rescinding them on 18 May 2026 (comment period closed 20 Jul 2026).
No Florida PFAS drinking-water standard in effect or proposed as of 2026-10-17: No state PFAS drinking-water MCL. Ch. 2022-203 Laws of Fla. (s. 376.91) concerns contaminated-site cleanup target levels, not drinking water.
Sampling history
Sampled 2025-01-06 to 2025-07-08 · 3 entry point(s) · water types: GW · 8 sampling visits. PFAS in ppt (ng/L).
| Date | Entry point | Event | PFOA | PFOS | HI | Other detections |
|---|---|---|---|---|---|---|
| 2025-01-06 | LADY LAKE CENTRAL WTP #1 (GW) | SE1 | n/a | n/a | n/a | none |
| 2025-01-06 | LADY LAKE CENTRAL WTP #2 (GW) | SE1 | n/a | n/a | n/a | none |
| 2025-01-06 | LADY LAKE CENTRAL WTP #3 (GW) | SE1 | <4 | <4 | 0.003 | none |
| 2025-02-12 | LADY LAKE CENTRAL WTP #1 (GW) | SE1 | 4.8 | 32.4 | 2.82 | PFHpA 3.5, PFHxA 5.9, PFPeA 6.7 |
| 2025-02-12 | LADY LAKE CENTRAL WTP #2 (GW) | SE1 | <4 | <4 | 0 | none |
| 2025-07-08 | LADY LAKE CENTRAL WTP #1 (GW) | SE2 | <4 | <4 | 0.313 | none |
| 2025-07-08 | LADY LAKE CENTRAL WTP #2 (GW) | SE2 | <4 | <4 | 0 | none |
| 2025-07-08 | LADY LAKE CENTRAL WTP #3 (GW) | SE2 | <4 | <4 | 0.002 | none |
“<4” = not detected at the reporting limit shown; “n/a” = not analyzed in that sample. Highlighted = at or above the 4 ppt MCL. HI computed per sample with non-detects as 0. Other detections lists every other quantified compound (lithium in µg/L).
All results by entry point
180 results. Each column is one sampling visit (date and UCMR 5 sample event). A number is a measured concentration; “< 4” = below the minimum reporting level shown; “–” = not analyzed in that visit. PFAS in ppt (ng/L); lithium in µg/L.
LADY LAKE CENTRAL WTP #1 facility 1 · sample point WTP1 · groundwater
| Compound | MRL | 2025-01-06 SE1 | 2025-02-12 SE1 | 2025-07-08 SE2 |
|---|---|---|---|---|
| PFBS | 3 ppt | – | 20.6 | 6 |
| PFHpA | 3 ppt | – | 3.5 | < 3 |
| PFHxA | 3 ppt | – | 5.9 | < 3 |
| PFHxS | 3 ppt | – | 24.1 | 3.1 |
| PFNA | 4 ppt | – | 4 | < 4 |
| PFOA | 4 ppt | – | 4.8 | < 4 |
| PFOS | 4 ppt | – | 32.4 | < 4 |
| PFPeA | 3 ppt | – | 6.7 | < 3 |
| 11Cl-PF3OUdS | 5 ppt | – | < 5 | < 5 |
| 4:2 FTS | 3 ppt | – | < 3 | < 3 |
| 6:2 FTS | 5 ppt | – | < 5 | < 5 |
| 8:2 FTS | 5 ppt | – | < 5 | < 5 |
| 9Cl-PF3ONS | 2 ppt | – | < 2 | < 2 |
| ADONA | 3 ppt | – | < 3 | < 3 |
| HFPO-DA | 5 ppt | – | < 5 | < 5 |
| NEtFOSAA | 5 ppt | < 5 | – | < 5 |
| NFDHA | 20 ppt | – | < 20 | < 20 |
| NMeFOSAA | 6 ppt | < 6 | – | < 6 |
| PFBA | 5 ppt | – | < 5 | < 5 |
| PFDA | 3 ppt | – | < 3 | < 3 |
| PFDoA | 3 ppt | – | < 3 | < 3 |
| PFEESA | 3 ppt | – | < 3 | < 3 |
| PFHpS | 3 ppt | – | < 3 | < 3 |
| PFMBA | 3 ppt | – | < 3 | < 3 |
| PFMPA | 4 ppt | – | < 4 | < 4 |
| PFPeS | 4 ppt | – | < 4 | < 4 |
| PFTA | 8 ppt | < 8 | – | < 8 |
| PFTrDA | 7 ppt | < 7 | – | < 7 |
| PFUnA | 2 ppt | – | < 2 | < 2 |
| lithium | 9 µg/L | < 9 | – | < 9 |
LADY LAKE CENTRAL WTP #2 facility 2 · sample point WTP2 · groundwater
| Compound | MRL | 2025-01-06 SE1 | 2025-02-12 SE1 | 2025-07-08 SE2 |
|---|---|---|---|---|
| 11Cl-PF3OUdS | 5 ppt | – | < 5 | < 5 |
| 4:2 FTS | 3 ppt | – | < 3 | < 3 |
| 6:2 FTS | 5 ppt | – | < 5 | < 5 |
| 8:2 FTS | 5 ppt | – | < 5 | < 5 |
| 9Cl-PF3ONS | 2 ppt | – | < 2 | < 2 |
| ADONA | 3 ppt | – | < 3 | < 3 |
| HFPO-DA | 5 ppt | – | < 5 | < 5 |
| NEtFOSAA | 5 ppt | < 5 | – | < 5 |
| NFDHA | 20 ppt | – | < 20 | < 20 |
| NMeFOSAA | 6 ppt | < 6 | – | < 6 |
| PFBA | 5 ppt | – | < 5 | < 5 |
| PFBS | 3 ppt | – | < 3 | < 3 |
| PFDA | 3 ppt | – | < 3 | < 3 |
| PFDoA | 3 ppt | – | < 3 | < 3 |
| PFEESA | 3 ppt | – | < 3 | < 3 |
| PFHpA | 3 ppt | – | < 3 | < 3 |
| PFHpS | 3 ppt | – | < 3 | < 3 |
| PFHxA | 3 ppt | – | < 3 | < 3 |
| PFHxS | 3 ppt | – | < 3 | < 3 |
| PFMBA | 3 ppt | – | < 3 | < 3 |
| PFMPA | 4 ppt | – | < 4 | < 4 |
| PFNA | 4 ppt | – | < 4 | < 4 |
| PFOA | 4 ppt | – | < 4 | < 4 |
| PFOS | 4 ppt | – | < 4 | < 4 |
| PFPeA | 3 ppt | – | < 3 | < 3 |
| PFPeS | 4 ppt | – | < 4 | < 4 |
| PFTA | 8 ppt | < 8 | – | < 8 |
| PFTrDA | 7 ppt | < 7 | – | < 7 |
| PFUnA | 2 ppt | – | < 2 | < 2 |
| lithium | 9 µg/L | < 9 | – | < 9 |
LADY LAKE CENTRAL WTP #3 facility 3 · sample point WTP3 · groundwater
| Compound | MRL | 2025-01-06 SE1 | 2025-07-08 SE2 |
|---|---|---|---|
| PFBS | 3 ppt | 5.3 | 3 |
| 11Cl-PF3OUdS | 5 ppt | < 5 | < 5 |
| 4:2 FTS | 3 ppt | < 3 | < 3 |
| 6:2 FTS | 5 ppt | < 5 | < 5 |
| 8:2 FTS | 5 ppt | < 5 | < 5 |
| 9Cl-PF3ONS | 2 ppt | < 2 | < 2 |
| ADONA | 3 ppt | < 3 | < 3 |
| HFPO-DA | 5 ppt | < 5 | < 5 |
| NEtFOSAA | 5 ppt | < 5 | < 5 |
| NFDHA | 20 ppt | < 20 | < 20 |
| NMeFOSAA | 6 ppt | < 6 | < 6 |
| PFBA | 5 ppt | < 5 | < 5 |
| PFDA | 3 ppt | < 3 | < 3 |
| PFDoA | 3 ppt | < 3 | < 3 |
| PFEESA | 3 ppt | < 3 | < 3 |
| PFHpA | 3 ppt | < 3 | < 3 |
| PFHpS | 3 ppt | < 3 | < 3 |
| PFHxA | 3 ppt | < 3 | < 3 |
| PFHxS | 3 ppt | < 3 | < 3 |
| PFMBA | 3 ppt | < 3 | < 3 |
| PFMPA | 4 ppt | < 4 | < 4 |
| PFNA | 4 ppt | < 4 | < 4 |
| PFOA | 4 ppt | < 4 | < 4 |
| PFOS | 4 ppt | < 4 | < 4 |
| PFPeA | 3 ppt | < 3 | < 3 |
| PFPeS | 4 ppt | < 4 | < 4 |
| PFTA | 8 ppt | < 8 | < 8 |
| PFTrDA | 7 ppt | < 7 | < 7 |
| PFUnA | 2 ppt | < 2 | < 2 |
| lithium | 9 µg/L | < 9 | < 9 |
Statistics by compound
| Compound | Results | Detected | Highest (date) | Mean bounds | KM median | P75 | P90 | P95 |
|---|---|---|---|---|---|---|---|---|
| PFBS | 6 | 67% | 20.6 2025-02-12 | 5.82–6.82 | 3 | 6 | 20.6 | 20.6 |
| PFHxS | 6 | 33% | 24.1 2025-02-12 | 4.53–6.53 | <MRL | 3.1 | 24.1 | 24.1 |
| PFHpA | 6 | 17% | 3.5 2025-02-12 | 0.58–3.08 | <MRL | <MRL | 3.5 | 3.5 |
| PFHxA | 6 | 17% | 5.9 2025-02-12 | 0.98–3.48 | <MRL | <MRL | 5.9 | 5.9 |
| PFNA | 6 | 17% | 4 2025-02-12 | 0.67–4 | <MRL | <MRL | 4 | 4 |
| PFOA | 6 | 17% | 4.8 2025-02-12 | 0.8–4.13 | <MRL | <MRL | 4.8 | 4.8 |
| PFOS | 6 | 17% | 32.4 2025-02-12 | 5.4–8.73 | <MRL | <MRL | 32.4 | 32.4 |
| PFPeA | 6 | 17% | 6.7 2025-02-12 | 1.12–3.62 | <MRL | <MRL | 6.7 | 6.7 |
Never detected (22): 11Cl-PF3OUdS, 4:2 FTS, 6:2 FTS, 8:2 FTS, 9Cl-PF3ONS, ADONA, HFPO-DA, NEtFOSAA, NFDHA, NMeFOSAA, PFBA, PFDA, PFDoA, PFEESA, PFHpS, PFMBA, PFMPA, PFPeS, PFTA, PFTrDA, PFUnA, lithium.
Left-censored Kaplan–Meier statistics (Helsel 2005; Helsel & Lee 2006, NADA for R). Units: ppt; lithium µg/L. Each compound has one reporting limit, so the Kaplan–Meier mean equals the upper mean bound (non-detects at the MRL); the lower bound sets non-detects to 0. “<MRL” = the percentile falls below the reporting limit and cannot be estimated. These describe this system's UCMR 5 samples, not population estimates.
Sources
- EPA UCMR 5 occurrence data text files (UCMR5_All.txt; samples 2023-01-03 to 2026-06-09; data summary dated Jul 2026)
- EPA SDWIS via ECHO SDWA downloads, quarter 2026Q3
- EPA Public Water System Service Areas v3 (Mar 2026)
- US Census Bureau cartographic boundary counties 1:500k, 2024
- EPA/USGS NHDPlus V2 (medium resolution) flowlines, Strahler order 2+
Data build 77d99d3b80c8 · 2026-10-18T04:10Z · UCMR 5 release Jul2026 · SDWIS 2026Q3. Data and methods.