- PWSID
- CA4210024
- State
- California
- System type
- community water system (CWS)
- Population served
- 4,861
- City
- Santa Barbara
- Counties
- Santa Barbara County
- Primary source water
- surface water (purchased)
- UCMR 5 sampling
- 2023-03-06 to 2024-06-04 · 3 entry point(s) · water types: GW;SW
- Service-area boundary
- authoritative
No PFAS detected highest single result
No PFAS detected worst entry-point average
Open on the California map · All California systems · All results
These are monitoring results collected under EPA's Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) at entry points, where treated water enters the distribution system; they are not tap-water samples. They are not compliance determinations: compliance with EPA's 2024 PFAS limits is judged on running annual averages of compliance monitoring, required from 2029, so a single UCMR 5 result at or above a limit is not a violation. “< MRL” means the compound was not quantified at EPA's minimum reporting level; it does not mean zero.
Water purchased from
- Goleta Water District (CA4210004)
Seller's highest results: PFOA <MRL · PFOS <MRL · HI 0 · detected: PFHxA;PFPeA - Central Coast Water Authority (CA4210030)
Seller not monitored under UCMR 5.
Seller results are the seller's own entry-point samples, not measurements of this system's water. This system's own samples (below) may reflect purchased water, its own sources, or both.
Compared with EPA's 2024 values
| Highest single result | Worst entry-point average* | Limit | |
|---|---|---|---|
| PFOA (ppt) | <MRL | 0 | 4 |
| PFOS (ppt) | <MRL | 0 | 4 |
| Hazard Index | 0 | 0 | 1.0† |
“<MRL” = every result for the compound was below its reporting limit. * Mean of all samples at each entry point with non-detects = 0 (EPA compliance convention; the Hazard Index also uses non-detects = 0); a screening comparison, not a formal running annual average. † Rescission proposed May 2026. PFOA/PFOS MCL 4 ppt (2024 NPDWR, in effect). PFHxS, PFNA, HFPO-DA (10 ppt each) and the Hazard Index (1.0) are 2024 NPDWR values; EPA proposed rescinding them on 18 May 2026 (comment period closed 20 Jul 2026).
Compared with California guidance levels
| Highest single result | Worst entry-point average* | California | |
|---|---|---|---|
| PFHxS (ppt) | 0 | 0 | 3 (guidance) |
| PFOA (ppt) | 0 | 0 | 4 (guidance) |
| PFOS (ppt) | 0 | 0 | 4 (guidance) |
| PFBS (ppt) | 0 | 0 | 500 (guidance) |
| PFHxA (ppt) | 0 | 0 | 1,000 (guidance) |
Sum standards add the listed compounds within each sample (non-detects = 0). State compliance is normally judged on averages over time; these are screening comparisons.
Sampling history
Sampled 2023-03-06 to 2024-06-04 · 3 entry point(s) · water types: GW;SW · 8 sampling visits. PFAS in ppt (ng/L).
| Date | Entry point | Event | PFOA | PFOS | HI | Other detections |
|---|---|---|---|---|---|---|
| 2023-03-06 | Nogal WTP (GW) | SE1 | <4 | <4 | 0 | lithium 51 µg/L |
| 2023-03-08 | Reservoir 1 Effluent (GW) | SE1 | <4 | <4 | 0 | lithium 45 µg/L |
| 2023-09-11 | Connection to Santa Barbara (SW) | SE1 | <4 | <4 | 0 | lithium 41.6 µg/L |
| 2023-09-11 | Nogal WTP (GW) | SE2 | <4 | <4 | 0 | lithium 66.9 µg/L |
| 2023-09-11 | Reservoir 1 Effluent (GW) | SE2 | <4 | <4 | 0 | lithium 67.9 µg/L |
| 2023-12-04 | Connection to Santa Barbara (SW) | SE2 | <4 | <4 | 0 | lithium 38.1 µg/L |
| 2024-03-11 | Connection to Santa Barbara (SW) | SE3 | <4 | <4 | 0 | lithium 33 µg/L |
| 2024-06-04 | Connection to Santa Barbara (SW) | SE4 | <4 | <4 | 0 | lithium 40.2 µg/L |
“<4” = not detected at the reporting limit shown; “n/a” = not analyzed in that sample. Highlighted = at or above the 4 ppt MCL. HI computed per sample with non-detects as 0. Other detections lists every other quantified compound (lithium in µg/L).
All results by entry point
240 results. Each column is one sampling visit (date and UCMR 5 sample event). A number is a measured concentration; “< 4” = below the minimum reporting level shown; “–” = not analyzed in that visit. PFAS in ppt (ng/L); lithium in µg/L.
Connection to Santa Barbara facility 10009 · sample point EP009 · surface water
| Compound | MRL | 2023-09-11 SE1 | 2023-12-04 SE2 | 2024-03-11 SE3 | 2024-06-04 SE4 |
|---|---|---|---|---|---|
| 11Cl-PF3OUdS | 5 ppt | < 5 | < 5 | < 5 | < 5 |
| 4:2 FTS | 3 ppt | < 3 | < 3 | < 3 | < 3 |
| 6:2 FTS | 5 ppt | < 5 | < 5 | < 5 | < 5 |
| 8:2 FTS | 5 ppt | < 5 | < 5 | < 5 | < 5 |
| 9Cl-PF3ONS | 2 ppt | < 2 | < 2 | < 2 | < 2 |
| ADONA | 3 ppt | < 3 | < 3 | < 3 | < 3 |
| HFPO-DA | 5 ppt | < 5 | < 5 | < 5 | < 5 |
| NEtFOSAA | 5 ppt | < 5 | < 5 | < 5 | < 5 |
| NFDHA | 20 ppt | < 20 | < 20 | < 20 | < 20 |
| NMeFOSAA | 6 ppt | < 6 | < 6 | < 6 | < 6 |
| PFBA | 5 ppt | < 5 | < 5 | < 5 | < 5 |
| PFBS | 3 ppt | < 3 | < 3 | < 3 | < 3 |
| PFDA | 3 ppt | < 3 | < 3 | < 3 | < 3 |
| PFDoA | 3 ppt | < 3 | < 3 | < 3 | < 3 |
| PFEESA | 3 ppt | < 3 | < 3 | < 3 | < 3 |
| PFHpA | 3 ppt | < 3 | < 3 | < 3 | < 3 |
| PFHpS | 3 ppt | < 3 | < 3 | < 3 | < 3 |
| PFHxA | 3 ppt | < 3 | < 3 | < 3 | < 3 |
| PFHxS | 3 ppt | < 3 | < 3 | < 3 | < 3 |
| PFMBA | 3 ppt | < 3 | < 3 | < 3 | < 3 |
| PFMPA | 4 ppt | < 4 | < 4 | < 4 | < 4 |
| PFNA | 4 ppt | < 4 | < 4 | < 4 | < 4 |
| PFOA | 4 ppt | < 4 | < 4 | < 4 | < 4 |
| PFOS | 4 ppt | < 4 | < 4 | < 4 | < 4 |
| PFPeA | 3 ppt | < 3 | < 3 | < 3 | < 3 |
| PFPeS | 4 ppt | < 4 | < 4 | < 4 | < 4 |
| PFTA | 8 ppt | < 8 | < 8 | < 8 | < 8 |
| PFTrDA | 7 ppt | < 7 | < 7 | < 7 | < 7 |
| PFUnA | 2 ppt | < 2 | < 2 | < 2 | < 2 |
| lithium | 9 µg/L | 41.6 | 38.1 | 33 | 40.2 |
Nogal WTP facility 10018 · sample point TP018 · groundwater
| Compound | MRL | 2023-03-06 SE1 | 2023-09-11 SE2 |
|---|---|---|---|
| 11Cl-PF3OUdS | 5 ppt | < 5 | < 5 |
| 4:2 FTS | 3 ppt | < 3 | < 3 |
| 6:2 FTS | 5 ppt | < 5 | < 5 |
| 8:2 FTS | 5 ppt | < 5 | < 5 |
| 9Cl-PF3ONS | 2 ppt | < 2 | < 2 |
| ADONA | 3 ppt | < 3 | < 3 |
| HFPO-DA | 5 ppt | < 5 | < 5 |
| NEtFOSAA | 5 ppt | < 5 | < 5 |
| NFDHA | 20 ppt | < 20 | < 20 |
| NMeFOSAA | 6 ppt | < 6 | < 6 |
| PFBA | 5 ppt | < 5 | < 5 |
| PFBS | 3 ppt | < 3 | < 3 |
| PFDA | 3 ppt | < 3 | < 3 |
| PFDoA | 3 ppt | < 3 | < 3 |
| PFEESA | 3 ppt | < 3 | < 3 |
| PFHpA | 3 ppt | < 3 | < 3 |
| PFHpS | 3 ppt | < 3 | < 3 |
| PFHxA | 3 ppt | < 3 | < 3 |
| PFHxS | 3 ppt | < 3 | < 3 |
| PFMBA | 3 ppt | < 3 | < 3 |
| PFMPA | 4 ppt | < 4 | < 4 |
| PFNA | 4 ppt | < 4 | < 4 |
| PFOA | 4 ppt | < 4 | < 4 |
| PFOS | 4 ppt | < 4 | < 4 |
| PFPeA | 3 ppt | < 3 | < 3 |
| PFPeS | 4 ppt | < 4 | < 4 |
| PFTA | 8 ppt | < 8 | < 8 |
| PFTrDA | 7 ppt | < 7 | < 7 |
| PFUnA | 2 ppt | < 2 | < 2 |
| lithium | 9 µg/L | 51 | 66.9 |
Reservoir 1 Effluent facility 10016 · sample point SS016 · groundwater
| Compound | MRL | 2023-03-08 SE1 | 2023-09-11 SE2 |
|---|---|---|---|
| 11Cl-PF3OUdS | 5 ppt | < 5 | < 5 |
| 4:2 FTS | 3 ppt | < 3 | < 3 |
| 6:2 FTS | 5 ppt | < 5 | < 5 |
| 8:2 FTS | 5 ppt | < 5 | < 5 |
| 9Cl-PF3ONS | 2 ppt | < 2 | < 2 |
| ADONA | 3 ppt | < 3 | < 3 |
| HFPO-DA | 5 ppt | < 5 | < 5 |
| NEtFOSAA | 5 ppt | < 5 | < 5 |
| NFDHA | 20 ppt | < 20 | < 20 |
| NMeFOSAA | 6 ppt | < 6 | < 6 |
| PFBA | 5 ppt | < 5 | < 5 |
| PFBS | 3 ppt | < 3 | < 3 |
| PFDA | 3 ppt | < 3 | < 3 |
| PFDoA | 3 ppt | < 3 | < 3 |
| PFEESA | 3 ppt | < 3 | < 3 |
| PFHpA | 3 ppt | < 3 | < 3 |
| PFHpS | 3 ppt | < 3 | < 3 |
| PFHxA | 3 ppt | < 3 | < 3 |
| PFHxS | 3 ppt | < 3 | < 3 |
| PFMBA | 3 ppt | < 3 | < 3 |
| PFMPA | 4 ppt | < 4 | < 4 |
| PFNA | 4 ppt | < 4 | < 4 |
| PFOA | 4 ppt | < 4 | < 4 |
| PFOS | 4 ppt | < 4 | < 4 |
| PFPeA | 3 ppt | < 3 | < 3 |
| PFPeS | 4 ppt | < 4 | < 4 |
| PFTA | 8 ppt | < 8 | < 8 |
| PFTrDA | 7 ppt | < 7 | < 7 |
| PFUnA | 2 ppt | < 2 | < 2 |
| lithium | 9 µg/L | 45 | 67.9 |
Statistics by compound
| Compound | Results | Detected | Highest (date) | Mean bounds | KM median | P75 | P90 | P95 |
|---|---|---|---|---|---|---|---|---|
| lithium | 8 | 100% | 67.9 2023-09-11 | 47.96–47.96 | 41.6 | 51 | 67.9 | 67.9 |
Never detected (29): 11Cl-PF3OUdS, 4:2 FTS, 6:2 FTS, 8:2 FTS, 9Cl-PF3ONS, ADONA, HFPO-DA, NEtFOSAA, NFDHA, NMeFOSAA, PFBA, PFBS, PFDA, PFDoA, PFEESA, PFHpA, PFHpS, PFHxA, PFHxS, PFMBA, PFMPA, PFNA, PFOA, PFOS, PFPeA, PFPeS, PFTA, PFTrDA, PFUnA.
Left-censored Kaplan–Meier statistics (Helsel 2005; Helsel & Lee 2006, NADA for R). Units: ppt; lithium µg/L. Each compound has one reporting limit, so the Kaplan–Meier mean equals the upper mean bound (non-detects at the MRL); the lower bound sets non-detects to 0. “<MRL” = the percentile falls below the reporting limit and cannot be estimated. These describe this system's UCMR 5 samples, not population estimates.
Sources
- EPA UCMR 5 occurrence data text files (UCMR5_All.txt; samples 2023-01-09 to 2026-06-17; data summary dated Jul 2026)
- EPA SDWIS via ECHO SDWA downloads, quarter 2026Q3
- EPA Public Water System Service Areas v3 (Mar 2026)
- US Census Bureau cartographic boundary counties 1:500k, 2024
- EPA/USGS NHDPlus V2 (medium resolution) flowlines, Strahler order 2+
Data build 90f0922cd84f · 2026-10-18T04:12Z · UCMR 5 release Jul2026 · SDWIS 2026Q3. Data and methods.