Upland, City Of

PFAS monitoring results for a public water system in California

CA3610050UCMR 5EPA monitoring data
<MRLHighest PFOA result, ppt
<MRLHighest PFOS result, ppt
0.002Highest Hazard Index
990Results
PWSID
CA3610050
State
California
System type
community water system (CWS)
Population served
78,376
City
Upland
Counties
San Bernardino County
Primary source water
surface water
UCMR 5 sampling
2024-04-01 to 2025-01-14 · 10 entry point(s) · water types: GW;MX;SW
Service-area boundary
authoritative

Hazard Index below its limit highest single result
Hazard Index below its limit worst entry-point average

These are monitoring results collected under EPA's Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) at entry points, where treated water enters the distribution system; they are not tap-water samples. They are not compliance determinations: compliance with EPA's 2024 PFAS limits is judged on running annual averages of compliance monitoring, required from 2029, so a single UCMR 5 result at or above a limit is not a violation. “< MRL” means the compound was not quantified at EPA's minimum reporting level; it does not mean zero.

Water purchased from

Seller results are the seller's own entry-point samples, not measurements of this system's water. This system's own samples (below) may reflect purchased water, its own sources, or both.

Compared with EPA's 2024 values

Highest single resultWorst entry-point average*Limit
PFOA (ppt)<MRL04
PFOS (ppt)<MRL04
Hazard Index0.0020.0011.0†

“<MRL” = every result for the compound was below its reporting limit. * Mean of all samples at each entry point with non-detects = 0 (EPA compliance convention; the Hazard Index also uses non-detects = 0); a screening comparison, not a formal running annual average. † Rescission proposed May 2026. PFOA/PFOS MCL 4 ppt (2024 NPDWR, in effect). PFHxS, PFNA, HFPO-DA (10 ppt each) and the Hazard Index (1.0) are 2024 NPDWR values; EPA proposed rescinding them on 18 May 2026 (comment period closed 20 Jul 2026).

Compared with California guidance levels

Highest single resultWorst entry-point average*California
PFHxS (ppt)003 (guidance)
PFOA (ppt)004 (guidance)
PFOS (ppt)004 (guidance)
PFBS (ppt)31.5500 (guidance)
PFHxA (ppt)5.55.351,000 (guidance)

Sum standards add the listed compounds within each sample (non-detects = 0). State compliance is normally judged on averages over time; these are screening comparisons.

Sampling history

Sampled 2024-04-01 to 2025-01-14 · 10 entry point(s) · water types: GW;MX;SW · 35 sampling visits. PFAS in ppt (ng/L).

DateEntry pointEventPFOAPFOSHIOther detections
2024-04-01City Well 20 (GW)SE1n/an/an/anone
2024-04-01City Well 7A (GW)SE1<4<40none
2024-04-01Cucamonga Valley Water District (MX)SE1<4<40none
2024-04-01Plant 13 (GW)SE1<4<40none
2024-04-01Plant 3 (MX)SE1<4<40none
2024-04-01Plant 4 (MX)SE1<4<40none
2024-04-01Plant 6 (MX)SE1<4<40none
2024-04-01Plant 7 (MX)SE1<4<40none
2024-04-01SAWCO 24th & Campus (MX)SE1n/an/an/anone
2024-04-01San Antonio Canyon Water Treament Plant (SW)SE1<4<40none
2024-04-17City Well 20 (GW)SE1<4<40PFHxA 5.5, PFPeA 5.7
2024-04-17SAWCO 24th & Campus (MX)SE1<4<40none
2024-07-11Cucamonga Valley Water District (MX)SE2<4<40none
2024-07-11Plant 3 (MX)SE2<4<40none
2024-07-11Plant 4 (MX)SE2<4<40none
2024-07-11Plant 6 (MX)SE2<4<40none
2024-07-11Plant 7 (MX)SE2<4<40none
2024-07-11SAWCO 24th & Campus (MX)SE2<4<40none
2024-07-11San Antonio Canyon Water Treament Plant (SW)SE2<4<40none
2024-10-07City Well 20 (GW)SE2<4<40.002PFHxA 5.2, PFPeA 5.4
2024-10-07City Well 7A (GW)SE2<4<40none
2024-10-07Cucamonga Valley Water District (MX)SE3<4<40none
2024-10-07Plant 13 (GW)SE2<4<40none
2024-10-07Plant 3 (MX)SE3<4<40none
2024-10-07Plant 4 (MX)SE3<4<40none
2024-10-07Plant 6 (MX)SE3<4<40none
2024-10-07Plant 7 (MX)SE3<4<40none
2024-10-07SAWCO 24th & Campus (MX)SE3<4<40none
2024-10-07San Antonio Canyon Water Treament Plant (SW)SE3<4<40none
2025-01-14Cucamonga Valley Water District (MX)SE4<4<40none
2025-01-14Plant 3 (MX)SE4<4<40none
2025-01-14Plant 4 (MX)SE4<4<40none
2025-01-14Plant 6 (MX)SE4<4<40none
2025-01-14Plant 7 (MX)SE4<4<40none
2025-01-14SAWCO 24th & Campus (MX)SE4<4<40none

“<4” = not detected at the reporting limit shown; “n/a” = not analyzed in that sample. Highlighted = at or above the 4 ppt MCL. HI computed per sample with non-detects as 0. Other detections lists every other quantified compound (lithium in µg/L).

All results by entry point

990 results. Each column is one sampling visit (date and UCMR 5 sample event). A number is a measured concentration; “< 4” = below the minimum reporting level shown; “–” = not analyzed in that visit. PFAS in ppt (ng/L); lithium in µg/L.

City Well 20 facility 91803 · sample point 3610050803 · groundwater

CompoundMRL2024-04-01
SE1
2024-04-17
SE1
2024-10-07
SE2
PFBS3 ppt–< 33
PFHxA3 ppt–5.55.2
PFPeA3 ppt–5.75.4
11Cl-PF3OUdS5 ppt–< 5< 5
4:2 FTS3 ppt–< 3< 3
6:2 FTS5 ppt–< 5< 5
8:2 FTS5 ppt–< 5< 5
9Cl-PF3ONS2 ppt–< 2< 2
ADONA3 ppt–< 3< 3
HFPO-DA5 ppt–< 5< 5
NEtFOSAA5 ppt< 5–< 5
NFDHA20 ppt–< 20< 20
NMeFOSAA6 ppt< 6–< 6
PFBA5 ppt–< 5< 5
PFDA3 ppt–< 3< 3
PFDoA3 ppt–< 3< 3
PFEESA3 ppt–< 3< 3
PFHpA3 ppt–< 3< 3
PFHpS3 ppt–< 3< 3
PFHxS3 ppt–< 3< 3
PFMBA3 ppt–< 3< 3
PFMPA4 ppt–< 4< 4
PFNA4 ppt–< 4< 4
PFOA4 ppt–< 4< 4
PFOS4 ppt–< 4< 4
PFPeS4 ppt–< 4< 4
PFTA8 ppt< 8–< 8
PFTrDA7 ppt< 7–< 7
PFUnA2 ppt–< 2< 2
lithium9 µg/L< 9–< 9

City Well 7A facility 91802 · sample point 3610050802 · groundwater

CompoundMRL2024-04-01
SE1
2024-10-07
SE2
11Cl-PF3OUdS5 ppt< 5< 5
4:2 FTS3 ppt< 3< 3
6:2 FTS5 ppt< 5< 5
8:2 FTS5 ppt< 5< 5
9Cl-PF3ONS2 ppt< 2< 2
ADONA3 ppt< 3< 3
HFPO-DA5 ppt< 5< 5
NEtFOSAA5 ppt< 5< 5
NFDHA20 ppt< 20< 20
NMeFOSAA6 ppt< 6< 6
PFBA5 ppt< 5< 5
PFBS3 ppt< 3< 3
PFDA3 ppt< 3< 3
PFDoA3 ppt< 3< 3
PFEESA3 ppt< 3< 3
PFHpA3 ppt< 3< 3
PFHpS3 ppt< 3< 3
PFHxA3 ppt< 3< 3
PFHxS3 ppt< 3< 3
PFMBA3 ppt< 3< 3
PFMPA4 ppt< 4< 4
PFNA4 ppt< 4< 4
PFOA4 ppt< 4< 4
PFOS4 ppt< 4< 4
PFPeA3 ppt< 3< 3
PFPeS4 ppt< 4< 4
PFTA8 ppt< 8< 8
PFTrDA7 ppt< 7< 7
PFUnA2 ppt< 2< 2
lithium9 µg/L< 9< 9

Cucamonga Valley Water District facility 50050 · sample point 3610050050 · MX

CompoundMRL2024-04-01
SE1
2024-07-11
SE2
2024-10-07
SE3
2025-01-14
SE4
11Cl-PF3OUdS5 ppt< 5< 5< 5< 5
4:2 FTS3 ppt< 3< 3< 3< 3
6:2 FTS5 ppt< 5< 5< 5< 5
8:2 FTS5 ppt< 5< 5< 5< 5
9Cl-PF3ONS2 ppt< 2< 2< 2< 2
ADONA3 ppt< 3< 3< 3< 3
HFPO-DA5 ppt< 5< 5< 5< 5
NEtFOSAA5 ppt< 5< 5< 5< 5
NFDHA20 ppt< 20< 20< 20< 20
NMeFOSAA6 ppt< 6< 6< 6< 6
PFBA5 ppt< 5< 5< 5< 5
PFBS3 ppt< 3< 3< 3< 3
PFDA3 ppt< 3< 3< 3< 3
PFDoA3 ppt< 3< 3< 3< 3
PFEESA3 ppt< 3< 3< 3< 3
PFHpA3 ppt< 3< 3< 3< 3
PFHpS3 ppt< 3< 3< 3< 3
PFHxA3 ppt< 3< 3< 3< 3
PFHxS3 ppt< 3< 3< 3< 3
PFMBA3 ppt< 3< 3< 3< 3
PFMPA4 ppt< 4< 4< 4< 4
PFNA4 ppt< 4< 4< 4< 4
PFOA4 ppt< 4< 4< 4< 4
PFOS4 ppt< 4< 4< 4< 4
PFPeA3 ppt< 3< 3< 3< 3
PFPeS4 ppt< 4< 4< 4< 4
PFTA8 ppt< 8< 8< 8< 8
PFTrDA7 ppt< 7< 7< 7< 7
PFUnA2 ppt< 2< 2< 2< 2
lithium9 µg/L< 9< 9< 9< 9

Plant 13 facility 50051 · sample point 3610050051 · groundwater

CompoundMRL2024-04-01
SE1
2024-10-07
SE2
11Cl-PF3OUdS5 ppt< 5< 5
4:2 FTS3 ppt< 3< 3
6:2 FTS5 ppt< 5< 5
8:2 FTS5 ppt< 5< 5
9Cl-PF3ONS2 ppt< 2< 2
ADONA3 ppt< 3< 3
HFPO-DA5 ppt< 5< 5
NEtFOSAA5 ppt< 5< 5
NFDHA20 ppt< 20< 20
NMeFOSAA6 ppt< 6< 6
PFBA5 ppt< 5< 5
PFBS3 ppt< 3< 3
PFDA3 ppt< 3< 3
PFDoA3 ppt< 3< 3
PFEESA3 ppt< 3< 3
PFHpA3 ppt< 3< 3
PFHpS3 ppt< 3< 3
PFHxA3 ppt< 3< 3
PFHxS3 ppt< 3< 3
PFMBA3 ppt< 3< 3
PFMPA4 ppt< 4< 4
PFNA4 ppt< 4< 4
PFOA4 ppt< 4< 4
PFOS4 ppt< 4< 4
PFPeA3 ppt< 3< 3
PFPeS4 ppt< 4< 4
PFTA8 ppt< 8< 8
PFTrDA7 ppt< 7< 7
PFUnA2 ppt< 2< 2
lithium9 µg/L< 9< 9

Plant 3 facility 50053 · sample point 3610050053 · MX

CompoundMRL2024-04-01
SE1
2024-07-11
SE2
2024-10-07
SE3
2025-01-14
SE4
11Cl-PF3OUdS5 ppt< 5< 5< 5< 5
4:2 FTS3 ppt< 3< 3< 3< 3
6:2 FTS5 ppt< 5< 5< 5< 5
8:2 FTS5 ppt< 5< 5< 5< 5
9Cl-PF3ONS2 ppt< 2< 2< 2< 2
ADONA3 ppt< 3< 3< 3< 3
HFPO-DA5 ppt< 5< 5< 5< 5
NEtFOSAA5 ppt< 5< 5< 5< 5
NFDHA20 ppt< 20< 20< 20< 20
NMeFOSAA6 ppt< 6< 6< 6< 6
PFBA5 ppt< 5< 5< 5< 5
PFBS3 ppt< 3< 3< 3< 3
PFDA3 ppt< 3< 3< 3< 3
PFDoA3 ppt< 3< 3< 3< 3
PFEESA3 ppt< 3< 3< 3< 3
PFHpA3 ppt< 3< 3< 3< 3
PFHpS3 ppt< 3< 3< 3< 3
PFHxA3 ppt< 3< 3< 3< 3
PFHxS3 ppt< 3< 3< 3< 3
PFMBA3 ppt< 3< 3< 3< 3
PFMPA4 ppt< 4< 4< 4< 4
PFNA4 ppt< 4< 4< 4< 4
PFOA4 ppt< 4< 4< 4< 4
PFOS4 ppt< 4< 4< 4< 4
PFPeA3 ppt< 3< 3< 3< 3
PFPeS4 ppt< 4< 4< 4< 4
PFTA8 ppt< 8< 8< 8< 8
PFTrDA7 ppt< 7< 7< 7< 7
PFUnA2 ppt< 2< 2< 2< 2
lithium9 µg/L< 9< 9< 9< 9

Plant 4 facility 50054 · sample point 3610050054 · MX

CompoundMRL2024-04-01
SE1
2024-07-11
SE2
2024-10-07
SE3
2025-01-14
SE4
11Cl-PF3OUdS5 ppt< 5< 5< 5< 5
4:2 FTS3 ppt< 3< 3< 3< 3
6:2 FTS5 ppt< 5< 5< 5< 5
8:2 FTS5 ppt< 5< 5< 5< 5
9Cl-PF3ONS2 ppt< 2< 2< 2< 2
ADONA3 ppt< 3< 3< 3< 3
HFPO-DA5 ppt< 5< 5< 5< 5
NEtFOSAA5 ppt< 5< 5< 5< 5
NFDHA20 ppt< 20< 20< 20< 20
NMeFOSAA6 ppt< 6< 6< 6< 6
PFBA5 ppt< 5< 5< 5< 5
PFBS3 ppt< 3< 3< 3< 3
PFDA3 ppt< 3< 3< 3< 3
PFDoA3 ppt< 3< 3< 3< 3
PFEESA3 ppt< 3< 3< 3< 3
PFHpA3 ppt< 3< 3< 3< 3
PFHpS3 ppt< 3< 3< 3< 3
PFHxA3 ppt< 3< 3< 3< 3
PFHxS3 ppt< 3< 3< 3< 3
PFMBA3 ppt< 3< 3< 3< 3
PFMPA4 ppt< 4< 4< 4< 4
PFNA4 ppt< 4< 4< 4< 4
PFOA4 ppt< 4< 4< 4< 4
PFOS4 ppt< 4< 4< 4< 4
PFPeA3 ppt< 3< 3< 3< 3
PFPeS4 ppt< 4< 4< 4< 4
PFTA8 ppt< 8< 8< 8< 8
PFTrDA7 ppt< 7< 7< 7< 7
PFUnA2 ppt< 2< 2< 2< 2
lithium9 µg/L< 9< 9< 9< 9

Plant 6 facility 50049 · sample point 3610050049 · MX

CompoundMRL2024-04-01
SE1
2024-07-11
SE2
2024-10-07
SE3
2025-01-14
SE4
11Cl-PF3OUdS5 ppt< 5< 5< 5< 5
4:2 FTS3 ppt< 3< 3< 3< 3
6:2 FTS5 ppt< 5< 5< 5< 5
8:2 FTS5 ppt< 5< 5< 5< 5
9Cl-PF3ONS2 ppt< 2< 2< 2< 2
ADONA3 ppt< 3< 3< 3< 3
HFPO-DA5 ppt< 5< 5< 5< 5
NEtFOSAA5 ppt< 5< 5< 5< 5
NFDHA20 ppt< 20< 20< 20< 20
NMeFOSAA6 ppt< 6< 6< 6< 6
PFBA5 ppt< 5< 5< 5< 5
PFBS3 ppt< 3< 3< 3< 3
PFDA3 ppt< 3< 3< 3< 3
PFDoA3 ppt< 3< 3< 3< 3
PFEESA3 ppt< 3< 3< 3< 3
PFHpA3 ppt< 3< 3< 3< 3
PFHpS3 ppt< 3< 3< 3< 3
PFHxA3 ppt< 3< 3< 3< 3
PFHxS3 ppt< 3< 3< 3< 3
PFMBA3 ppt< 3< 3< 3< 3
PFMPA4 ppt< 4< 4< 4< 4
PFNA4 ppt< 4< 4< 4< 4
PFOA4 ppt< 4< 4< 4< 4
PFOS4 ppt< 4< 4< 4< 4
PFPeA3 ppt< 3< 3< 3< 3
PFPeS4 ppt< 4< 4< 4< 4
PFTA8 ppt< 8< 8< 8< 8
PFTrDA7 ppt< 7< 7< 7< 7
PFUnA2 ppt< 2< 2< 2< 2
lithium9 µg/L< 9< 9< 9< 9

Plant 7 facility 50052 · sample point 3610050052 · MX

CompoundMRL2024-04-01
SE1
2024-07-11
SE2
2024-10-07
SE3
2025-01-14
SE4
11Cl-PF3OUdS5 ppt< 5< 5< 5< 5
4:2 FTS3 ppt< 3< 3< 3< 3
6:2 FTS5 ppt< 5< 5< 5< 5
8:2 FTS5 ppt< 5< 5< 5< 5
9Cl-PF3ONS2 ppt< 2< 2< 2< 2
ADONA3 ppt< 3< 3< 3< 3
HFPO-DA5 ppt< 5< 5< 5< 5
NEtFOSAA5 ppt< 5< 5< 5< 5
NFDHA20 ppt< 20< 20< 20< 20
NMeFOSAA6 ppt< 6< 6< 6< 6
PFBA5 ppt< 5< 5< 5< 5
PFBS3 ppt< 3< 3< 3< 3
PFDA3 ppt< 3< 3< 3< 3
PFDoA3 ppt< 3< 3< 3< 3
PFEESA3 ppt< 3< 3< 3< 3
PFHpA3 ppt< 3< 3< 3< 3
PFHpS3 ppt< 3< 3< 3< 3
PFHxA3 ppt< 3< 3< 3< 3
PFHxS3 ppt< 3< 3< 3< 3
PFMBA3 ppt< 3< 3< 3< 3
PFMPA4 ppt< 4< 4< 4< 4
PFNA4 ppt< 4< 4< 4< 4
PFOA4 ppt< 4< 4< 4< 4
PFOS4 ppt< 4< 4< 4< 4
PFPeA3 ppt< 3< 3< 3< 3
PFPeS4 ppt< 4< 4< 4< 4
PFTA8 ppt< 8< 8< 8< 8
PFTrDA7 ppt< 7< 7< 7< 7
PFUnA2 ppt< 2< 2< 2< 2
lithium9 µg/L< 9< 9< 9< 9

SAWCO 24th & Campus facility 50047 · sample point 3610050047 · MX

CompoundMRL2024-04-01
SE1
2024-04-17
SE1
2024-07-11
SE2
2024-10-07
SE3
2025-01-14
SE4
11Cl-PF3OUdS5 ppt–< 5< 5< 5< 5
4:2 FTS3 ppt–< 3< 3< 3< 3
6:2 FTS5 ppt–< 5< 5< 5< 5
8:2 FTS5 ppt–< 5< 5< 5< 5
9Cl-PF3ONS2 ppt–< 2< 2< 2< 2
ADONA3 ppt–< 3< 3< 3< 3
HFPO-DA5 ppt–< 5< 5< 5< 5
NEtFOSAA5 ppt< 5–< 5< 5< 5
NFDHA20 ppt–< 20< 20< 20< 20
NMeFOSAA6 ppt< 6–< 6< 6< 6
PFBA5 ppt–< 5< 5< 5< 5
PFBS3 ppt–< 3< 3< 3< 3
PFDA3 ppt–< 3< 3< 3< 3
PFDoA3 ppt–< 3< 3< 3< 3
PFEESA3 ppt–< 3< 3< 3< 3
PFHpA3 ppt–< 3< 3< 3< 3
PFHpS3 ppt–< 3< 3< 3< 3
PFHxA3 ppt–< 3< 3< 3< 3
PFHxS3 ppt–< 3< 3< 3< 3
PFMBA3 ppt–< 3< 3< 3< 3
PFMPA4 ppt–< 4< 4< 4< 4
PFNA4 ppt–< 4< 4< 4< 4
PFOA4 ppt–< 4< 4< 4< 4
PFOS4 ppt–< 4< 4< 4< 4
PFPeA3 ppt–< 3< 3< 3< 3
PFPeS4 ppt–< 4< 4< 4< 4
PFTA8 ppt< 8–< 8< 8< 8
PFTrDA7 ppt< 7–< 7< 7< 7
PFUnA2 ppt–< 2< 2< 2< 2
lithium9 µg/L< 9–< 9< 9< 9

San Antonio Canyon Water Treament Plant facility 50004 · sample point 3610050004 · surface water

CompoundMRL2024-04-01
SE1
2024-07-11
SE2
2024-10-07
SE3
11Cl-PF3OUdS5 ppt< 5< 5< 5
4:2 FTS3 ppt< 3< 3< 3
6:2 FTS5 ppt< 5< 5< 5
8:2 FTS5 ppt< 5< 5< 5
9Cl-PF3ONS2 ppt< 2< 2< 2
ADONA3 ppt< 3< 3< 3
HFPO-DA5 ppt< 5< 5< 5
NEtFOSAA5 ppt< 5< 5< 5
NFDHA20 ppt< 20< 20< 20
NMeFOSAA6 ppt< 6< 6< 6
PFBA5 ppt< 5< 5< 5
PFBS3 ppt< 3< 3< 3
PFDA3 ppt< 3< 3< 3
PFDoA3 ppt< 3< 3< 3
PFEESA3 ppt< 3< 3< 3
PFHpA3 ppt< 3< 3< 3
PFHpS3 ppt< 3< 3< 3
PFHxA3 ppt< 3< 3< 3
PFHxS3 ppt< 3< 3< 3
PFMBA3 ppt< 3< 3< 3
PFMPA4 ppt< 4< 4< 4
PFNA4 ppt< 4< 4< 4
PFOA4 ppt< 4< 4< 4
PFOS4 ppt< 4< 4< 4
PFPeA3 ppt< 3< 3< 3
PFPeS4 ppt< 4< 4< 4
PFTA8 ppt< 8< 8< 8
PFTrDA7 ppt< 7< 7< 7
PFUnA2 ppt< 2< 2< 2
lithium9 µg/L< 9< 9< 9

Statistics by compound

CompoundResultsDetectedHighest (date)Mean boundsKM medianP75P90P95
PFHxA336%5.5
2024-04-17
0.32–3.14<MRL<MRL<MRL5.2
PFPeA336%5.7
2024-04-17
0.34–3.15<MRL<MRL<MRL5.4
PFBS333%3
2024-10-07
0.09–3<MRL<MRL<MRL<MRL

Never detected (27): 11Cl-PF3OUdS, 4:2 FTS, 6:2 FTS, 8:2 FTS, 9Cl-PF3ONS, ADONA, HFPO-DA, NEtFOSAA, NFDHA, NMeFOSAA, PFBA, PFDA, PFDoA, PFEESA, PFHpA, PFHpS, PFHxS, PFMBA, PFMPA, PFNA, PFOA, PFOS, PFPeS, PFTA, PFTrDA, PFUnA, lithium.

Left-censored Kaplan–Meier statistics (Helsel 2005; Helsel & Lee 2006, NADA for R). Units: ppt; lithium µg/L. Each compound has one reporting limit, so the Kaplan–Meier mean equals the upper mean bound (non-detects at the MRL); the lower bound sets non-detects to 0. “<MRL” = the percentile falls below the reporting limit and cannot be estimated. These describe this system's UCMR 5 samples, not population estimates.

Sources

  • EPA UCMR 5 occurrence data text files (UCMR5_All.txt; samples 2023-01-09 to 2026-06-17; data summary dated Jul 2026)
  • EPA SDWIS via ECHO SDWA downloads, quarter 2026Q3
  • EPA Public Water System Service Areas v3 (Mar 2026)
  • US Census Bureau cartographic boundary counties 1:500k, 2024
  • EPA/USGS NHDPlus V2 (medium resolution) flowlines, Strahler order 2+

Data build 90f0922cd84f · 2026-10-18T04:12Z · UCMR 5 release Jul2026 · SDWIS 2026Q3. Data and methods.