Wasilla Water System

PFAS monitoring results for a public water system in Alaska

AK2224646UCMR 5EPA monitoring data
<MRLHighest PFOA result, ppt
<MRLHighest PFOS result, ppt
0.42Highest Hazard Index
300Results
PWSID
AK2224646
State
Alaska
System type
community water system (CWS)
Population served
18,492
City
Wasilla
Counties
Matanuska-Susitna Borough
Primary source water
groundwater
UCMR 5 sampling
2023-08-15 to 2024-03-18 · 5 entry point(s) · water types: GW
Service-area boundary
authoritative

Hazard Index below its limit highest single result
Hazard Index below its limit worst entry-point average

These are monitoring results collected under EPA's Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) at entry points, where treated water enters the distribution system; they are not tap-water samples. They are not compliance determinations: compliance with EPA's 2024 PFAS limits is judged on running annual averages of compliance monitoring, required from 2029, so a single UCMR 5 result at or above a limit is not a violation. “< MRL” means the compound was not quantified at EPA's minimum reporting level; it does not mean zero.

Compared with EPA's 2024 values

Highest single resultWorst entry-point average*Limit
PFOA (ppt)<MRL04
PFOS (ppt)<MRL04
Hazard Index0.420.3651.0†

“<MRL” = every result for the compound was below its reporting limit. * Mean of all samples at each entry point with non-detects = 0 (EPA compliance convention; the Hazard Index also uses non-detects = 0); a screening comparison, not a formal running annual average. † Rescission proposed May 2026. PFOA/PFOS MCL 4 ppt (2024 NPDWR, in effect). PFHxS, PFNA, HFPO-DA (10 ppt each) and the Hazard Index (1.0) are 2024 NPDWR values; EPA proposed rescinding them on 18 May 2026 (comment period closed 20 Jul 2026).

No Alaska PFAS drinking-water standard in effect or proposed as of 2026-10-17: No Alaska-specific PFAS standard for public water systems; DEC Drinking Water Program implements the federal NPDWR (DEC PFAS page, revised 2025-10-29).

Sampling history

Sampled 2023-08-15 to 2024-03-18 · 5 entry point(s) · water types: GW · 11 sampling visits. PFAS in ppt (ng/L).

DateEntry pointEventPFOAPFOSHIOther detections
2023-08-15Bumpus Wells #1 & #2 (GW)SE1<4<40none
2023-08-15East Susitna Wells #1 & #2 (GW)SE1<4<40.31none
2023-08-15MISSION HILLS (GW)SE1<4<40none
2023-08-15Spruce Main Well (GW)SE1<4<40none
2023-08-23RANCH WELL (GW)SE1<4<40none
2024-02-05Bumpus Wells #1 & #2 (GW)SE2<4<40none
2024-02-05East Susitna Wells #1 & #2 (GW)SE2<4<40.42none
2024-02-05MISSION HILLS (GW)SE2n/an/an/anone
2024-02-05RANCH WELL (GW)SE2<4<40none
2024-02-05Spruce Main Well (GW)SE2<4<40none
2024-03-18MISSION HILLS (GW)SE2<4<40none

“<4” = not detected at the reporting limit shown; “n/a” = not analyzed in that sample. Highlighted = at or above the 4 ppt MCL. HI computed per sample with non-detects as 0. Other detections lists every other quantified compound (lithium in µg/L).

All results by entry point

300 results. Each column is one sampling visit (date and UCMR 5 sample event). A number is a measured concentration; “< 4” = below the minimum reporting level shown; “–” = not analyzed in that visit. PFAS in ppt (ng/L); lithium in µg/L.

Bumpus Wells #1 & #2 facility 32116 · sample point 34556 · groundwater

CompoundMRL2023-08-15
SE1
2024-02-05
SE2
11Cl-PF3OUdS5 ppt< 5< 5
4:2 FTS3 ppt< 3< 3
6:2 FTS5 ppt< 5< 5
8:2 FTS5 ppt< 5< 5
9Cl-PF3ONS2 ppt< 2< 2
ADONA3 ppt< 3< 3
HFPO-DA5 ppt< 5< 5
NEtFOSAA5 ppt< 5< 5
NFDHA20 ppt< 20< 20
NMeFOSAA6 ppt< 6< 6
PFBA5 ppt< 5< 5
PFBS3 ppt< 3< 3
PFDA3 ppt< 3< 3
PFDoA3 ppt< 3< 3
PFEESA3 ppt< 3< 3
PFHpA3 ppt< 3< 3
PFHpS3 ppt< 3< 3
PFHxA3 ppt< 3< 3
PFHxS3 ppt< 3< 3
PFMBA3 ppt< 3< 3
PFMPA4 ppt< 4< 4
PFNA4 ppt< 4< 4
PFOA4 ppt< 4< 4
PFOS4 ppt< 4< 4
PFPeA3 ppt< 3< 3
PFPeS4 ppt< 4< 4
PFTA8 ppt< 8< 8
PFTrDA7 ppt< 7< 7
PFUnA2 ppt< 2< 2
lithium9 µg/L< 9< 9

East Susitna Wells #1 & #2 facility 48211 · sample point 37666 · groundwater

CompoundMRL2023-08-15
SE1
2024-02-05
SE2
PFHxS3 ppt3.14.2
11Cl-PF3OUdS5 ppt< 5< 5
4:2 FTS3 ppt< 3< 3
6:2 FTS5 ppt< 5< 5
8:2 FTS5 ppt< 5< 5
9Cl-PF3ONS2 ppt< 2< 2
ADONA3 ppt< 3< 3
HFPO-DA5 ppt< 5< 5
NEtFOSAA5 ppt< 5< 5
NFDHA20 ppt< 20< 20
NMeFOSAA6 ppt< 6< 6
PFBA5 ppt< 5< 5
PFBS3 ppt< 3< 3
PFDA3 ppt< 3< 3
PFDoA3 ppt< 3< 3
PFEESA3 ppt< 3< 3
PFHpA3 ppt< 3< 3
PFHpS3 ppt< 3< 3
PFHxA3 ppt< 3< 3
PFMBA3 ppt< 3< 3
PFMPA4 ppt< 4< 4
PFNA4 ppt< 4< 4
PFOA4 ppt< 4< 4
PFOS4 ppt< 4< 4
PFPeA3 ppt< 3< 3
PFPeS4 ppt< 4< 4
PFTA8 ppt< 8< 8
PFTrDA7 ppt< 7< 7
PFUnA2 ppt< 2< 2
lithium9 µg/L< 9< 9

MISSION HILLS facility 78212 · sample point TP004 · groundwater

CompoundMRL2023-08-15
SE1
2024-02-05
SE2
2024-03-18
SE2
11Cl-PF3OUdS5 ppt< 5–< 5
4:2 FTS3 ppt< 3–< 3
6:2 FTS5 ppt< 5–< 5
8:2 FTS5 ppt< 5–< 5
9Cl-PF3ONS2 ppt< 2–< 2
ADONA3 ppt< 3–< 3
HFPO-DA5 ppt< 5–< 5
NEtFOSAA5 ppt< 5< 5–
NFDHA20 ppt< 20–< 20
NMeFOSAA6 ppt< 6< 6–
PFBA5 ppt< 5–< 5
PFBS3 ppt< 3–< 3
PFDA3 ppt< 3–< 3
PFDoA3 ppt< 3–< 3
PFEESA3 ppt< 3–< 3
PFHpA3 ppt< 3–< 3
PFHpS3 ppt< 3–< 3
PFHxA3 ppt< 3–< 3
PFHxS3 ppt< 3–< 3
PFMBA3 ppt< 3–< 3
PFMPA4 ppt< 4–< 4
PFNA4 ppt< 4–< 4
PFOA4 ppt< 4–< 4
PFOS4 ppt< 4–< 4
PFPeA3 ppt< 3–< 3
PFPeS4 ppt< 4–< 4
PFTA8 ppt< 8< 8–
PFTrDA7 ppt< 7< 7–
PFUnA2 ppt< 2–< 2
lithium9 µg/L< 9< 9–

RANCH WELL facility 58212 · sample point SPTP005 · groundwater

CompoundMRL2023-08-23
SE1
2024-02-05
SE2
11Cl-PF3OUdS5 ppt< 5< 5
4:2 FTS3 ppt< 3< 3
6:2 FTS5 ppt< 5< 5
8:2 FTS5 ppt< 5< 5
9Cl-PF3ONS2 ppt< 2< 2
ADONA3 ppt< 3< 3
HFPO-DA5 ppt< 5< 5
NEtFOSAA5 ppt< 5< 5
NFDHA20 ppt< 20< 20
NMeFOSAA6 ppt< 6< 6
PFBA5 ppt< 5< 5
PFBS3 ppt< 3< 3
PFDA3 ppt< 3< 3
PFDoA3 ppt< 3< 3
PFEESA3 ppt< 3< 3
PFHpA3 ppt< 3< 3
PFHpS3 ppt< 3< 3
PFHxA3 ppt< 3< 3
PFHxS3 ppt< 3< 3
PFMBA3 ppt< 3< 3
PFMPA4 ppt< 4< 4
PFNA4 ppt< 4< 4
PFOA4 ppt< 4< 4
PFOS4 ppt< 4< 4
PFPeA3 ppt< 3< 3
PFPeS4 ppt< 4< 4
PFTA8 ppt< 8< 8
PFTrDA7 ppt< 7< 7
PFUnA2 ppt< 2< 2
lithium9 µg/L< 9< 9

Spruce Main Well facility 32450 · sample point 34557 · groundwater

CompoundMRL2023-08-15
SE1
2024-02-05
SE2
11Cl-PF3OUdS5 ppt< 5< 5
4:2 FTS3 ppt< 3< 3
6:2 FTS5 ppt< 5< 5
8:2 FTS5 ppt< 5< 5
9Cl-PF3ONS2 ppt< 2< 2
ADONA3 ppt< 3< 3
HFPO-DA5 ppt< 5< 5
NEtFOSAA5 ppt< 5< 5
NFDHA20 ppt< 20< 20
NMeFOSAA6 ppt< 6< 6
PFBA5 ppt< 5< 5
PFBS3 ppt< 3< 3
PFDA3 ppt< 3< 3
PFDoA3 ppt< 3< 3
PFEESA3 ppt< 3< 3
PFHpA3 ppt< 3< 3
PFHpS3 ppt< 3< 3
PFHxA3 ppt< 3< 3
PFHxS3 ppt< 3< 3
PFMBA3 ppt< 3< 3
PFMPA4 ppt< 4< 4
PFNA4 ppt< 4< 4
PFOA4 ppt< 4< 4
PFOS4 ppt< 4< 4
PFPeA3 ppt< 3< 3
PFPeS4 ppt< 4< 4
PFTA8 ppt< 8< 8
PFTrDA7 ppt< 7< 7
PFUnA2 ppt< 2< 2
lithium9 µg/L< 9< 9

Statistics by compound

CompoundResultsDetectedHighest (date)Mean boundsKM medianP75P90P95
PFHxS1020%4.2
2024-02-05
0.73–3.13<MRL<MRL3.14.2

Never detected (29): 11Cl-PF3OUdS, 4:2 FTS, 6:2 FTS, 8:2 FTS, 9Cl-PF3ONS, ADONA, HFPO-DA, NEtFOSAA, NFDHA, NMeFOSAA, PFBA, PFBS, PFDA, PFDoA, PFEESA, PFHpA, PFHpS, PFHxA, PFMBA, PFMPA, PFNA, PFOA, PFOS, PFPeA, PFPeS, PFTA, PFTrDA, PFUnA, lithium.

Left-censored Kaplan–Meier statistics (Helsel 2005; Helsel & Lee 2006, NADA for R). Units: ppt; lithium µg/L. Each compound has one reporting limit, so the Kaplan–Meier mean equals the upper mean bound (non-detects at the MRL); the lower bound sets non-detects to 0. “<MRL” = the percentile falls below the reporting limit and cannot be estimated. These describe this system's UCMR 5 samples, not population estimates.

Sources

  • EPA UCMR 5 occurrence data text files (UCMR5_All.txt; samples 2023-01-08 to 2026-03-02; data summary dated Jul 2026)
  • EPA SDWIS via ECHO SDWA downloads, quarter 2026Q3
  • EPA Public Water System Service Areas v3 (Mar 2026)
  • US Census Bureau cartographic boundary counties 1:500k, 2024
  • U.S. Geological Survey, 2014, 1:1,000,000-Scale Streams of the United States (streaml010g), National Map Small-Scale Collection; Strahler order 2+ on the 1:1M network (NHDPlus V2 does not cover Alaska). Coarser than the NHDPlus layer used for other states; mapped streams do not extend west of about 170.7 W (western Aleutians)

Data build f5ae0997fdb0 · 2026-10-18T04:03Z · UCMR 5 release Jul2026 · SDWIS 2026Q3. Data and methods.